# Rainwood Sweeteners — full technical text > Supplier of high-intensity sweeteners, polyols, rare sugars and soluble fibres for food, beverage and supplement manufacturers, with a batch COA, a stated analytical method and taste and solubility data for every specification. Legal entity: Shaanxi Rainwood Biotech Co., Ltd.. Location: Rm 218, Tangxing Digital Bldg, #6 Tangxing Rd, Xi'an, Shaanxi, China. Contact: info@rainwoodbio.com. Scope: sweetener ingredients and blends only. No OEM, ODM, private label or finished foods. Availability: all 59 published specifications are in production and available to order; the batch COA, packing and lead time are confirmed against the order. Certificates: NSF 455-2 GMP, ISO 22000, HACCP, ISO 9001, HALAL, USDA Organic and EU Organic; current copies are available with the quotation. ## Site map - Home: https://sweeteners.rainwoodbio.com/ - Sweetener catalog: https://sweeteners.rainwoodbio.com/products/ - Plant-derived high-intensity: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/ - Quality and documentation: https://sweeteners.rainwoodbio.com/quality/ - About and scope: https://sweeteners.rainwoodbio.com/about/ - Editorial policy: https://sweeteners.rainwoodbio.com/editorial-policy/ - Privacy: https://sweeteners.rainwoodbio.com/privacy/ - Contact: https://sweeteners.rainwoodbio.com/contact/ ## Published specifications ### Plant-Derived Sweeteners & Sweet Proteins The plant-derived shelf is crowded with names that hide chemistry. "Stevia" can mean a 95% total glycoside extract, a 98% Reb A powder or a Reb M grade fermented from a different starting material. Monk fruit can be a fruit powder, a 30% mogroside extract or a 50% Mogroside V concentrate. This range is built around the exact molecule or molecule family on the label, the HPLC method used to measure it, and the taste and solubility data a formulator needs before a bench trial. #### Steviol Glycosides 95% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/steviol-glycosides/ Identity: Purified steviol glycoside extract, ≥95% total glycosides Formula: Steviol glycoside mixture (mainly stevioside and rebaudioside A) CAS: 57817-89-7 (stevioside) Summary: A 95% total steviol glycoside powder for beverages, tabletop and reduced-sugar foods, specified by the glycoside profile rather than a single stevia percentage. Specification: - Total steviol glycosides: ≥95.0% (HPLC) - Rebaudioside A: 40.0–60.0% (HPLC) - Stevioside: 20.0–35.0% (HPLC) - Rebaudioside C: ≤10.0% (HPLC) - Appearance: White to off-white powder - Moisture: ≤5.0% - pH (1% solution): 4.5–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.30–0.60 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Tabletop sweeteners, Dairy and plant-based drinks, Confectionery, Supplements - Sweetness: 200–300 × sucrose, indicative - Taste: Sweet with a slower onset and a liquorice-like linger at higher doses; mouthfeel thins in water unless a bulk sweetener is added. - Solubility: Freely soluble in water; solutions are clear at typical use levels and remain stable across beverage pH. #### Rebaudioside A 98% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-a/ Identity: Rebaudioside A, purified steviol glycoside Formula: C₄₄H₇₀O₂₃ CAS: 58543-16-1 Summary: A 98% Rebaudioside A powder for clean-taste beverages and tabletop, with the stevioside fraction controlled and the glycoside profile stated on the COA. Specification: - Rebaudioside A: ≥98.0% (HPLC) - Total steviol glycosides: ≥99.0% (HPLC) - Stevioside: ≤1.0% (HPLC) - Rebaudioside C: ≤0.5% (HPLC) - Appearance: White to off-white powder - Moisture: ≤3.0% - pH (1% solution): 4.5–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.30–0.60 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Tabletop, Dairy alternatives, Confectionery, Supplements - Sweetness: 200–300 × sucrose, indicative - Taste: Cleaner than a total glycoside grade, with a faster onset and less liquorice linger; a sweet aftertaste remains at high dose. - Solubility: Freely soluble in water; clear at use levels and compatible with typical beverage processing. #### Rebaudioside M 95% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-m/ Identity: Rebaudioside M, high-purity steviol glycoside Formula: C₅₆H₉₀O₃₃ CAS: 1220616-44-3 Summary: A 95% Rebaudioside M grade for premium beverages that need a faster, cleaner sweetness than Reb A, with the minor glycoside profile stated on the COA. Specification: - Rebaudioside M: ≥95.0% (HPLC) - Total steviol glycosides: ≥98.0% (HPLC) - Rebaudioside A: ≤2.0% (HPLC) - Stevioside: ≤0.5% (HPLC) - Appearance: White to off-white powder - Moisture: ≤3.0% - pH (1% solution): 4.5–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.30–0.60 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Premium beverages, Tabletop, Dairy alternatives, Functional drinks, Supplements - Sweetness: 250–350 × sucrose, indicative - Taste: Faster onset and cleaner finish than Reb A, with less liquorice linger; still sweet after the swallow at high dose. - Solubility: Freely soluble in water; clear solution at typical beverage use levels. #### Monk Fruit Extract 50% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-extract/ Identity: Water-extracted monk fruit concentrate, ≥50% Mogroside V Formula: Mogroside V and related cucurbitane glycosides CAS: 88901-36-4 (Mogroside V) Summary: A 50% Mogroside V monk fruit extract for beverages and foods, specified by the mogroside profile and supplied with taste and solubility data. Specification: - Mogroside V: ≥50.0% (HPLC) - Total mogrosides: ≥60.0% (HPLC) - Appearance: Light yellow to off-white powder - Moisture: ≤5.0% - pH (1% solution): 4.0–7.0 - Solubility: Soluble in water; slight haze at high concentration - Particle size: ≥95% through 80 mesh - Bulk density: 0.35–0.65 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Tabletop, Dairy alternatives, Confectionery, Sauces - Sweetness: 150–250 × sucrose, indicative for a 50% Mogroside V extract - Taste: Clean, fruit-forward sweetness with a melon-like note at high dose; less liquorice linger than stevia. - Solubility: Soluble in water; a slight haze can appear at high concentration and should be checked in clear beverages. #### Glycyrrhizin 98% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glycyrrhizin/ Identity: Glycyrrhizic acid, purified from licorice root Formula: C₄₂H₆₂O₁₆ CAS: 1405-86-3 Summary: A 98% glycyrrhizic acid powder for flavour and sweetness modification, with the salt form, use level and taste profile stated before the sample ships. Specification: - Glycyrrhizic acid: ≥98.0% (HPLC) - Appearance: White to light yellow powder - Moisture: ≤6.0% - pH (1% solution): 4.5–6.5 - Solubility: Sparingly soluble in water; soluble in alkaline solution - Particle size: ≥95% through 80 mesh - Bulk density: 0.35–0.65 g/mL - Ash: ≤1.0% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Flavour systems, Confectionery, Sauces, Beverages, Oral care - Sweetness: 50–100 × sucrose, indicative; slow onset and a long liquorice linger - Taste: Liquorice sweetness with a slow onset and a very long tail; at high dose the anise note dominates. - Solubility: Sparingly soluble in water; solubility rises with pH, which is why the salt form is often easier to formulate. #### Naringin Dihydrochalcone (NDC) 98% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/naringin-dihydrochalcone/ Identity: Naringin dihydrochalcone, hydrogenated citrus flavonoid Formula: C₂₇H₃₄O₁₄ CAS: 18916-17-1 Summary: A 98% naringin dihydrochalcone (NDC) powder used at very low levels to build sweetness and modify bitterness, with its long linger and cooling note documented before application trials. Specification: - Naringin dihydrochalcone: ≥98.0% (HPLC) - Naringin: ≤1.0% (HPLC) - Appearance: White to off-white powder - Moisture: ≤5.0% - pH (1% solution): 5.0–7.0 - Solubility: Slightly soluble in water; soluble in ethanol - Particle size: ≥95% through 80 mesh - Bulk density: 0.35–0.65 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Confectionery, Flavour systems, Oral care, Chewing gum - Sweetness: 1,000–2,000 × sucrose, indicative - Taste: Very intense sweetness with a slow onset, a long lingering tail and a cooling, slightly menthol-like note at higher doses. - Solubility: Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. #### Thaumatin URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/thaumatin/ Identity: Purified sweet protein from Thaumatococcus daniellii Formula: Thaumatin protein (thaumatin I and II) CAS: 53850-34-3 Summary: A purified thaumatin protein for trace-level sweetness and mouthfeel, with the protein content, solubility and allergen assessment stated before use. Specification: - Protein (thaumatin): ≥95.0% (dry basis) - Appearance: White to cream-coloured powder - Moisture: ≤10.0% - pH (1% solution): 5.0–7.5 - Solubility: Freely soluble in water - Particle size: ≥95% through 100 mesh - Bulk density: 0.25–0.55 g/mL - Ash: ≤3.0% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy, Confectionery, Oral care, Supplements - Sweetness: 2,000–3,000 × sucrose, indicative - Taste: Slow onset, intense sweetness with a liquorice-like tail; at low dose it adds body and rounds other sweeteners. - Solubility: Freely soluble in water; solutions are protein systems and need a preservation and pH strategy. #### Neohesperidin Dihydrochalcone (NHDC) 98% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/neohesperidin-dihydrochalcone/ Identity: Neohesperidin dihydrochalcone, hydrogenated citrus flavonoid Formula: C₂₈H₃₆O₁₅ CAS: 20702-77-6 Summary: A 98% neohesperidin dihydrochalcone for trace-level sweetness, bitterness modification and mouthfeel, with a clear distinction from naringin DC. Specification: - Neohesperidin dihydrochalcone: ≥98.0% (HPLC) - Neohesperidin: ≤1.0% (HPLC) - Appearance: White to off-white powder - Moisture: ≤5.0% - pH (1% solution): 5.0–7.0 - Solubility: Slightly soluble in water; soluble in ethanol - Particle size: ≥95% through 80 mesh - Bulk density: 0.35–0.65 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Confectionery, Chewing gum, Oral care, Flavour systems - Sweetness: 1,500–2,000 × sucrose, indicative - Taste: Intense sweetness with a slow onset, a long lingering tail and a cooling, slightly menthol-like note at higher doses. - Solubility: Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. #### Monoammonium Glycyrrhizinate 98% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monoammonium-glycyrrhizinate/ Identity: Monoammonium glycyrrhizinate, water-soluble licorice derivative Formula: C₄₂H₆₅NO₁₆ CAS: 53956-04-0 Summary: A 98% monoammonium glycyrrhizinate for water-soluble licorice sweetness and flavour modification, with the salt form stated separately from glycyrrhizic acid. Specification: - Monoammonium glycyrrhizinate: ≥98.0% (HPLC) - Glycyrrhizic acid: ≥65.0% (calculated) - Appearance: White to cream-coloured powder - Moisture: ≤6.0% - pH (1% solution): 5.0–7.0 - Solubility: Soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.35–0.65 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Flavour systems, Confectionery, Beverages, Oral care, Sauces - Sweetness: 50–100 × sucrose, indicative - Taste: Liquorice sweetness with a slow onset and a long tail; the ammonium salt is easier to dissolve than the acid. - Solubility: Soluble in water; easier to formulate than the free acid in neutral systems. #### Dipotassium Glycyrrhizinate 98% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/dipotassium-glycyrrhizinate/ Identity: Dipotassium glycyrrhizinate, water-soluble licorice derivative Formula: C₄₂H₆₀K₂O₁₆ CAS: 68797-35-3 Summary: A 98% dipotassium glycyrrhizinate for water-soluble licorice sweetness and flavour, with a separate salt form and taste profile from the ammonium salt and the free acid. Specification: - Dipotassium glycyrrhizinate: ≥98.0% (HPLC) - Glycyrrhizic acid: ≥65.0% (calculated) - Appearance: White to cream-coloured powder - Moisture: ≤6.0% - pH (1% solution): 6.0–8.0 - Solubility: Soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.35–0.65 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Flavour systems, Oral care, Beverages, Confectionery, Cosmetic-adjacent food systems - Sweetness: 50–100 × sucrose, indicative - Taste: Liquorice sweetness with a long tail; the potassium salt is useful where a sodium or ammonium salt is not wanted. - Solubility: Soluble in water; a neutral-to-mildly-alkaline solution. #### Rubusoside 70% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rubusoside/ Identity: Rubusoside, sweet-tea glycoside extract Formula: C₃₂H₅₀O₁₃ CAS: 64849-39-4 Summary: A 70% rubusoside extract from sweet tea for natural high-intensity sweetness, with the glycoside profile and technical data stated before application work. Specification: - Rubusoside: ≥70.0% (HPLC) - Total sweet glycosides: ≥80.0% (HPLC) - Appearance: White to off-white powder - Moisture: ≤5.0% - pH (1% solution): 4.5–7.0 - Solubility: Soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.35–0.65 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy alternatives, Confectionery, Tabletop, Supplements - Sweetness: 100–200 × sucrose, indicative - Taste: Sweet with a slower onset and a clean finish; a slight herbal note at higher doses. - Solubility: Soluble in water; clear at typical use levels. #### Glucosylated Steviol Glycosides 90% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glucosylated-steviol-glycosides/ Identity: Enzyme-glucosylated steviol glycosides, ≥90% total glycosides Formula: Glucosylated steviol glycoside mixture CAS: — Summary: A 90% glucosylated steviol glycoside for improved solubility and a cleaner sweetness, with the enzyme route stated separately from steviol glycosides. Specification: - Total steviol glycosides: ≥90.0% (HPLC) - Glucosylated glycosides: ≥60.0% (HPLC) - Appearance: White to off-white powder - Moisture: ≤5.0% - pH (1% solution): 4.5–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.35–0.65 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy alternatives, Tabletop, Confectionery, Supplements - Sweetness: 100–200 × sucrose, indicative - Taste: Sweet with a rounded onset and less linger than Reb A; the glucosylation changes the mouthfeel. - Solubility: Freely soluble in water; improved solubility versus high-purity Reb A. #### Brazzein 90% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/brazzein/ Identity: Brazzein protein, 90% on a protein basis Formula: Brazzein sweet protein CAS: — Summary: A 90% brazzein sweet protein for high-intensity sweetness, with the carrier, protein identity and handling requirements stated up front. Specification: - Brazzein protein: ≥90.0% (protein basis) - Appearance: White to off-white powder - Moisture: ≤8.0% - pH (1% solution): 4.5–7.0 - Solubility: Soluble in water - Particle size: ≥95% through 100 mesh - Bulk density: 0.25–0.55 g/mL - Ash: ≤3.0% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy alternatives, Confectionery, Tabletop, Supplements - Sweetness: 1,000–2,000 × sucrose, indicative for the 90% protein - Taste: Clean, fast-onset sweetness with a long tail; at high dose a slight protein note can appear. - Solubility: Soluble in water; a protein solution needs a pH and preservation strategy. #### Monellin 90% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monellin/ Identity: Monellin protein, 90% on a protein basis Formula: Monellin sweet protein CAS: — Summary: A 90% monellin sweet protein for high-intensity sweetness, with the protein identity and handling requirements stated before the trial. Specification: - Monellin protein: ≥90.0% (protein basis) - Appearance: White to off-white powder - Moisture: ≤8.0% - pH (1% solution): 4.5–7.0 - Solubility: Soluble in water - Particle size: ≥95% through 100 mesh - Bulk density: 0.25–0.55 g/mL - Ash: ≤3.0% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy alternatives, Confectionery, Tabletop, Supplements - Sweetness: 2,000–3,000 × sucrose, indicative for the 90% protein - Taste: Intense sweetness with a slow onset and a long tail; the protein can add body. - Solubility: Soluble in water; a protein solution needs a pH and preservation strategy. #### Monk Fruit Powder 10% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-powder/ Identity: Spray-dried monk fruit powder, 10% total mogrosides Formula: Siraitia grosvenorii fruit powder, 10% mogrosides CAS: — Summary: A spray-dried monk fruit powder with 10% total mogrosides for food and beverage colour, body and mild sweetness, positioned separately from the 50% high-intensity extract. Specification: - Total mogrosides: ≥10.0% (HPLC) - Mogroside V: ≥6.0% (HPLC) - Appearance: Light yellow to light brown powder - Moisture: ≤5.0% - pH (1% solution): 4.0–7.0 - Solubility: Soluble or dispersible in water; some fruit solids may haze - Particle size: ≥95% through 80 mesh - Bulk density: 0.35–0.65 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy alternatives, Bakery, Confectionery, Supplements - Sweetness: 10–20 × sucrose, indicative - Taste: Mild, fruit-forward sweetness with a melon note; more colour and body than the high-purity extract. - Solubility: Soluble or dispersible in water; fruit solids can haze a clear beverage. ### High-Intensity Sweeteners High-intensity sweeteners are bought on a purity figure and then fail on something else: a particle size that will not disperse, a related-substance profile that drifts on storage, a blend that segregates on the line, or a label name that does not match the salt supplied. This range states the exact sweetener, its assay and impurity panel, its sweetness and stability profile, and the forms available. Every lot carries a batch COA and a specification comparison against the grade requested. #### Sucralose URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sucralose/ Identity: Trichlorogalactosucrose, crystalline powder Formula: C₁₂H₁₉Cl₃O₈ CAS: 56038-13-2 Summary: A high-purity sucralose powder for beverages, dairy and tabletop, specified by assay, related substances and particle size, with the form chosen for the line. Specification: - Assay (dried basis): 98.0–102.0% (HPLC) - Related substances: ≤2.0% (HPLC) - Appearance: White to off-white crystalline powder - Moisture: ≤1.0% - pH (10% solution): 5.0–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh; micronized on request - Bulk density: 0.50–0.80 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy, Tabletop, Bakery, Confectionery - Sweetness: 400–600 × sucrose, indicative - Taste: Clean, sucrose-like onset with a slight lingering sweetness; the tail is shorter than saccharin but longer than aspartame. - Solubility: Freely soluble in water; clear solutions at use levels. #### Acesulfame Potassium URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/acesulfame-potassium/ Identity: Acesulfame potassium salt, crystalline powder Formula: C₄H₄KNO₄S CAS: 55589-62-3 Summary: A 99% acesulfame potassium powder for beverage and tabletop blends, specified by assay, potassium content and particle size for the line. Specification: - Assay (dried basis): 99.0–101.0% (HPLC) - Potassium (K): 17.0–19.0% (titration) - Appearance: White crystalline powder - Moisture: ≤1.0% - pH (1% solution): 5.5–7.5 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.60–0.90 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Tabletop, Confectionery, Bakery, Dairy - Sweetness: 180–200 × sucrose, indicative - Taste: Fast onset with a bitter, metallic linger at higher doses; rarely used alone in a clean-finish beverage. - Solubility: Freely soluble in water; solutions are neutral to slightly alkaline. #### Aspartame URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame/ Identity: L-aspartyl-L-phenylalanine methyl ester, crystalline powder Formula: C₁₄H₁₈N₂O₅ CAS: 22839-47-0 Summary: A 99% aspartame powder with a sucrose-like sweetness, specified by assay, related substances and phenylalanine content, for beverages and tabletop where the application fits. Specification: - Assay (dried basis): 98.0–102.0% (HPLC) - L-Phenylalanine: 47.0–52.0% (HPLC) - Related substances: ≤2.0% (HPLC) - Appearance: White crystalline powder - Moisture: ≤4.5% - pH (1% solution): 4.5–6.0 - Solubility: Sparingly soluble in water; more soluble at lower pH - Particle size: ≥95% through 80 mesh - Bulk density: 0.30–0.60 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Tabletop, Dairy, Confectionery, Chewing gum - Sweetness: 180–220 × sucrose, indicative - Taste: Clean, sucrose-like sweetness with a slower onset than Ace-K and a shorter tail than saccharin. - Solubility: Sparingly soluble in water; solubility increases at lower pH, and dissolution time matters in a beverage line. #### Saccharin Sodium (Dihydrate) URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/saccharin-sodium/ Identity: Sodium saccharin dihydrate, crystalline powder Formula: C₇H₅NNaO₃S·2H₂O CAS: 6155-57-3 Summary: A sodium saccharin dihydrate for tabletop and cost-sensitive sweetening, specified by assay on the dried basis, moisture and the metallic-tail taste that limits its use. Specification: - Assay (dried basis): 99.0–101.0% (HPLC) - Appearance: White crystalline powder or granules - Moisture: 13.5–15.0% (dihydrate) - pH (10% solution): 5.0–8.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh; granular on request - Bulk density: 0.60–0.90 g/mL - Benzoate and salicylate: Absent by the specified test - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Tabletop, Beverages, Confectionery, Oral care, Chewing gum - Sweetness: 300–500 × sucrose, indicative - Taste: Fast, intense sweetness with a metallic and bitter linger; rarely used alone in a premium-taste application. - Solubility: Freely soluble in water; the dihydrate loses water on heating and should not be dried before use. #### Neotame URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/neotame/ Identity: N-[N-(3,3-dimethylbutyl)-L-α-aspartyl]-L-phenylalanine 1-methyl ester Formula: C₂₀H₃₀N₂O₅ CAS: 165450-17-9 Summary: A high-intensity neotame powder for very low-use-rate sweetening, specified by assay, related substances and the carrier or form needed for accurate dosing. Specification: - Assay (dried basis): 97.0–102.0% (HPLC) - Related substances: ≤2.0% (HPLC) - Appearance: White to off-white powder - Moisture: ≤5.0% - pH (0.5% solution): 5.0–7.0 - Solubility: Sparingly soluble in water - Particle size: ≥95% through 100 mesh - Bulk density: 0.30–0.60 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Confectionery, Tabletop, Dairy, Chewing gum - Sweetness: 7,000–13,000 × sucrose, indicative - Taste: Clean sweetness with a slower onset and a slight linger; at very low use levels the aftertaste is less pronounced than saccharin. - Solubility: Sparingly soluble in water; a pre-diluted premix is usually needed at food use levels. #### Advantame URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/advantame/ Identity: Advantame, high-potency aspartame derivative Formula: C₂₄H₃₀N₂O₇ CAS: 714229-20-6 Summary: An advantame powder for very high-potency sweetening, supplied with the trace-use and premix guidance that the dose level requires. Specification: - Assay (dried basis): 97.0–102.0% (HPLC) - Related substances: ≤2.0% (HPLC) - Appearance: White to off-white powder - Moisture: ≤5.0% - pH (0.5% solution): 5.0–7.0 - Solubility: Sparingly soluble in water - Particle size: ≥95% through 100 mesh - Bulk density: 0.30–0.60 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Confectionery, Tabletop, Dairy, Chewing gum - Sweetness: 20,000 × sucrose, indicative - Taste: Clean sweetness with a slower onset and a long tail; use level is so low that carrier and homogeneity dominate the taste result. - Solubility: Sparingly soluble in water; a pre-diluted premix is needed at food use levels. #### Sodium Cyclamate URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sodium-cyclamate/ Identity: Sodium cyclamate, crystalline powder Formula: C₆H₁₂NNaO₃S CAS: 139-05-9 Summary: A sodium cyclamate for cost-sensitive sweetening, supplied with the salt form, assay and solubility data for the application. Specification: - Assay (dried basis): 98.0–101.0% - Cyclohexyl sulfamate: ≥98.0% - Appearance: White crystalline powder - Moisture: ≤1.0% - pH (10% solution): 5.5–8.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.55–0.85 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Tabletop, Confectionery, Dairy, Sauces - Sweetness: 30–50 × sucrose, indicative - Taste: Sweet with a slower onset and a slight bitter note; usually blended with another high-intensity sweetener. - Solubility: Freely soluble in water; clear solutions at use levels. #### Aspartame-Acesulfame Salt (E962) URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame-acesulfame-salt/ Identity: 1:1 salt of aspartame and acesulfame Formula: Aspartame-acesulfame salt CAS: 106372-55-8 Summary: A 1:1 aspartame-acesulfame salt for a rounded sweetness in beverages, with a defined ratio and homogeneity separate from a physical blend. Specification: - Aspartame: 53.0–57.0% (HPLC) - Acesulfame: 38.0–42.0% (HPLC) - Appearance: White crystalline powder - Moisture: ≤2.0% - pH (1% solution): 3.0–5.0 - Solubility: Sparingly soluble in water; solubility increases at lower pH - Particle size: ≥95% through 80 mesh - Bulk density: 0.30–0.60 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Tabletop, Dairy, Confectionery, Chewing gum - Sweetness: 300–350 × sucrose, indicative - Taste: Rounded sweetness with a faster onset than aspartame alone and a shorter tail than Ace-K alone. - Solubility: Sparingly soluble in water; more soluble at lower pH. ### Polyols & Sugar Alcohols A polyol is a bulk ingredient, so the specification has to cover more than sweetness: crystal form, particle size, moisture, hygroscopicity and behaviour in cooking or conching all change the finished product. Erythritol cools strongly and crystallises cleanly; sorbitol picks up water; maltitol can brown; isomalt is chosen for hard candy. This range puts those differences on the specification, with the assay method and the physical data a product developer can work from. #### Erythritol URL: https://sweeteners.rainwoodbio.com/products/polyols/erythritol/ Identity: Erythritol, crystalline polyol Formula: C₄H₁₀O₄ CAS: 149-32-6 Summary: A 99.5% erythritol crystal for sugar-free beverages, confectionery and tabletop, specified by moisture, particle size and the cooling effect that defines its mouthfeel. Specification: - Assay (dried basis): 99.0–100.5% (HPLC-RI) - Appearance: White crystalline granules or powder - Moisture: ≤0.2% - pH (5% solution): 5.0–7.0 - Solubility: Soluble in water; endothermic dissolution produces a cooling effect - Particle size: 20–60 mesh or 80 mesh powder - Bulk density: 0.60–0.90 g/mL - Reducing sugars: ≤0.3% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Confectionery, Tabletop, Chocolate, Bakery - Sweetness: 60–70% of sucrose, indicative - Taste: Clean sweetness with a pronounced cooling effect; the cooling is desirable in mint and beverage applications and a problem in some baked goods. - Solubility: Soluble in water; dissolution is endothermic, which produces the characteristic cooling effect. #### Xylitol URL: https://sweeteners.rainwoodbio.com/products/polyols/xylitol/ Identity: Xylitol, crystalline polyol Formula: C₅H₁₂O₅ CAS: 87-99-0 Summary: A 99% xylitol crystal with a sucrose-like sweetness and a strong cooling effect, for confectionery, oral care and tabletop. Specification: - Assay (dried basis): 98.5–101.0% (HPLC-RI) - Appearance: White crystalline powder or granules - Moisture: ≤0.5% - pH (5% solution): 5.0–7.0 - Solubility: Freely soluble in water; endothermic dissolution - Particle size: ≥95% through 60 mesh; 80 mesh on request - Bulk density: 0.55–0.85 g/mL - Other polyols: ≤0.5% (HPLC) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Chewing gum, Confectionery, Tabletop, Oral care, Beverages - Sweetness: 90–100% of sucrose, indicative - Taste: Sweetness close to sucrose with a strong cooling effect and a clean finish; the cooling can dominate at high dose. - Solubility: Freely soluble in water; strongly endothermic, with a cooling effect that is more pronounced than erythritol's. #### Sorbitol URL: https://sweeteners.rainwoodbio.com/products/polyols/sorbitol/ Identity: D-Glucitol, crystalline powder or aqueous solution Formula: C₆H₁₄O₆ CAS: 50-70-4 Summary: A sorbitol powder and 70% solution for humectancy, sugar-free bulk and tablet filling, specified by assay, moisture and the form that matches the process. Specification: - Assay (dried basis): 97.0–101.0% (HPLC-RI) - Appearance: White crystalline powder or granules - Moisture: ≤1.0% (powder) - pH (5% solution): 4.5–7.0 - Solubility: Freely soluble in water; hygroscopic - Particle size: ≥95% through 60 mesh; granular on request - Bulk density: 0.55–0.85 g/mL - Reducing sugars: ≤0.2% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum; 250 kg drum for solution - Applications: Confectionery, Bakery, Oral care, Tabletting, Beverages - Sweetness: 50–60% of sucrose, indicative - Taste: Mild sweetness with a slight cooling effect and a soft mouthfeel; less sweet than xylitol. - Solubility: Freely soluble in water; strongly hygroscopic and used as a humectant as well as a sweetener. #### Maltitol URL: https://sweeteners.rainwoodbio.com/products/polyols/maltitol/ Identity: Maltitol, crystalline powder or granules Formula: C₁₂H₂₄O₁₁ CAS: 585-88-6 Summary: A 99% maltitol crystal with a sweetness close to sucrose, for sugar-free chocolate, bakery and confectionery where browning and mouthfeel matter. Specification: - Assay (dried basis): 98.0–101.0% (HPLC-RI) - Appearance: White crystalline powder or granules - Moisture: ≤1.0% - pH (5% solution): 4.5–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 60 mesh; granular on request - Bulk density: 0.55–0.85 g/mL - Other polyols: ≤1.0% (HPLC) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Chocolate, Confectionery, Bakery, Tabletop, Ice cream - Sweetness: 90% of sucrose, indicative - Taste: Close to sucrose with a soft mouthfeel and little cooling; the sweetness can carry a slight malt note. - Solubility: Freely soluble in water; less cooling than erythritol or xylitol. #### Isomalt URL: https://sweeteners.rainwoodbio.com/products/polyols/isomalt/ Identity: Isomalt, crystalline granules or powder Formula: 1,6-GPS and 1,1-GPM mixture CAS: 64519-82-0 Summary: An isomalt for sugar-free hard candy and baked goods, specified by the GPS/GPM ratio, moisture and particle size for moulding and conching. Specification: - Isomalt content: ≥98.0% (HPLC-RI) - 1,6-GPS : 1,1-GPM: 43–57 : 43–57 (HPLC) - Appearance: White crystalline granules or powder - Moisture: ≤0.5% - pH (10% solution): 4.5–7.0 - Solubility: Soluble in water; low hygroscopicity - Particle size: ≥95% through 40 mesh; powder on request - Bulk density: 0.60–0.90 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Sugar-free hard candy, Tabletop, Bakery, Chocolate, Chewing gum - Sweetness: 45–60% of sucrose, indicative - Taste: Mild sweetness with little cooling and a clean finish; the sweetness is lower than maltitol or xylitol. - Solubility: Soluble in water; low hygroscopicity makes it useful in hard candy and dusty environments. #### Mannitol URL: https://sweeteners.rainwoodbio.com/products/polyols/mannitol/ Identity: D-Mannitol, crystalline powder or granules Formula: C₆H₁₄O₆ CAS: 69-65-8 Summary: A mannitol powder for tabletting, sugar-free chewing gum and bakery, specified by assay, particle size and the compactibility that decides a tablet. Specification: - Assay (dried basis): 98.0–101.0% (HPLC-RI) - Appearance: White crystalline powder or granules - Moisture: ≤0.5% - pH (5% solution): 5.0–7.5 - Solubility: Soluble in water; less hygroscopic than sorbitol - Particle size: ≥95% through 60 mesh; spray-dried on request - Bulk density: 0.50–0.80 g/mL - Reducing sugars: ≤0.1% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Tabletting, Chewing gum, Bakery, Confectionery, Oral care - Sweetness: 50–70% of sucrose, indicative - Taste: Mild sweetness with a cooling effect and a slightly dry mouthfeel; the tablet mouthfeel is grade-dependent. - Solubility: Soluble in water; low hygroscopicity and a cooling effect, with good tablet compaction in the right grade. #### Lactitol Monohydrate URL: https://sweeteners.rainwoodbio.com/products/polyols/lactitol/ Identity: Lactitol monohydrate, crystalline powder Formula: C₁₂H₂₄O₁₁·H₂O CAS: 81025-04-9 Summary: A lactitol monohydrate for sugar-free chocolate, bakery and confectionery, with a clean sweetness, low hygroscopicity and a sugar-like body. Specification: - Lactitol (dry basis): ≥98.0% (HPLC-RI) - Appearance: White crystalline powder - Moisture: ≤0.5% (monohydrate basis) - pH (10% solution): 4.5–7.0 - Solubility: Soluble in water; low hygroscopicity - Particle size: ≥95% through 60 mesh - Bulk density: 0.55–0.85 g/mL - Other polyols: ≤1.0% (HPLC-RI) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Sugar-free chocolate, Bakery, Confectionery, Ice cream, Tabletop - Sweetness: 30–40% of sucrose, indicative - Taste: Mild, clean sweetness with little cooling; useful where a sugar-like body is wanted without the sweetness of maltitol. - Solubility: Soluble in water; low hygroscopicity and a clean, mild sweetness. #### Hydrogenated Starch Hydrolysates (HSH) URL: https://sweeteners.rainwoodbio.com/products/polyols/hydrogenated-starch-hydrolysate/ Identity: Polyglycitol syrup, 75% solids Formula: Hydrogenated starch hydrolysate mixture CAS: — Summary: A hydrogenated starch hydrolysate syrup for sugar-free candy, bakery and ice cream, specified by the polyol distribution, solids and viscosity. Specification: - Total polyols (dry basis): ≥95.0% (HPLC-RI) - Solids: 74.0–76.0% (refractometer) - Sorbitol: 10.0–20.0% (HPLC-RI) - Maltitol: 30.0–50.0% (HPLC-RI) - Appearance: Colourless to light yellow syrup - pH (10% solution): 4.5–7.0 - Ash: ≤0.1% - Viscosity: Specified at 25 °C for the grade - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Sugar-free candy, Bakery, Ice cream, Chews, Tabletop - Sweetness: 30–50% of sucrose, indicative - Taste: Mild sweetness with body and humectancy; less cooling than erythritol or xylitol. - Solubility: Fully soluble in water; supplied as a syrup. ### Rare & Functional Sugars Rare and functional sugars sit between bulk sweeteners and specialty ingredients. Allulose browns like a sugar and delivers a clean sweetness with useful browning and body; tagatose is a low-abundance ketose with a different sweetness curve; trehalose protects proteins; isomaltulose and crystalline fructose add functional bulk. This range states the anomer or hydrate where it matters, the assay method, the sweetness profile and the physical behaviour that governs use. #### Allulose URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/allulose/ Identity: D-Allulose, crystalline powder or liquid Formula: C₆H₁₂O₆ CAS: 551-68-8 Summary: A crystalline allulose for reduced-sugar beverages, bakery and frozen desserts, with the browning and sweetness behaviour of a sugar and the physical data stated up front. Specification: - Assay (dried basis): 98.0–102.0% (HPLC-RI) - Appearance: White crystalline powder - Moisture: ≤1.0% - pH (10% solution): 4.0–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 60 mesh - Bulk density: 0.50–0.80 g/mL - Other sugars: ≤1.0% (HPLC) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Bakery, Frozen desserts, Confectionery, Tabletop - Sweetness: 60–70% of sucrose, indicative - Taste: Clean sweetness close to sucrose with a slightly slower onset and a clean finish; it browns and bulks like a sugar. - Solubility: Freely soluble in water; solutions are clean and compatible with beverage processing. #### Tagatose URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/tagatose/ Identity: D-Tagatose, crystalline powder Formula: C₆H₁₂O₆ CAS: 87-81-0 Summary: A crystalline tagatose for reduced-sugar confectionery and beverages, with a sucrose-like sweetness and browning behaviour described before the trial. Specification: - Assay (dried basis): 98.0–102.0% (HPLC-RI) - Appearance: White crystalline powder - Moisture: ≤1.0% - pH (10% solution): 4.0–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 60 mesh - Bulk density: 0.50–0.80 g/mL - Other sugars: ≤1.0% (HPLC) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Confectionery, Bakery, Tabletop, Dairy - Sweetness: 90% of sucrose, indicative - Taste: Sucrose-like sweetness with a slight cooling effect and a clean finish; at high dose a subtle fruit note can appear. - Solubility: Freely soluble in water; clean solutions at use levels. #### Trehalose Dihydrate URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/trehalose/ Identity: Trehalose dihydrate, crystalline powder Formula: C₁₂H₂₂O₁₁·2H₂O CAS: 6138-23-4 Summary: A trehalose dihydrate with mild sweetness and low hygroscopicity, for protein protection, bakery and beverage systems where the hydrate is part of the specification. Specification: - Assay (dried basis): 98.0–101.0% (HPLC-RI) - Appearance: White crystalline powder - Moisture: 9.0–11.0% (dihydrate) - pH (10% solution): 4.5–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 60 mesh - Bulk density: 0.55–0.85 g/mL - Other sugars: ≤1.0% (HPLC) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Bakery, Beverages, Protein systems, Confectionery, Frozen desserts - Sweetness: 45% of sucrose, indicative - Taste: Mild, clean sweetness with no strong cooling; at high dose it can add body rather than sweetness. - Solubility: Freely soluble in water; low hygroscopicity and a clean, mild sweetness. #### L-Arabinose URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/l-arabinose/ Identity: L-Arabinose, crystalline powder Formula: C₅H₁₀O₅ CAS: 5328-37-0 Summary: An L-arabinose for sweetness modification and reduced-sugar systems, specified by assay, other sugars and the low sweetness that makes it a modifier rather than a bulk sugar. Specification: - Assay (dried basis): 98.0–101.0% (HPLC-RI) - Appearance: White crystalline powder - Moisture: ≤0.5% - pH (5% solution): 4.0–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 60 mesh - Bulk density: 0.50–0.80 g/mL - Other sugars: ≤1.0% (HPLC) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Confectionery, Bakery, Tabletop, Sauces - Sweetness: 40–50% of sucrose, indicative - Taste: Mild, clean sweetness with a slight cooling effect; used at low levels as a sweetness modifier rather than a bulk sweetener. - Solubility: Freely soluble in water; clean solutions at use levels. #### D-Xylose URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/d-xylose/ Identity: D-Xylose, crystalline powder Formula: C₅H₁₀O₅ CAS: 58-86-6 Summary: A D-xylose for flavour systems, colour development and specialty food use, specified by assay, other sugars and the market position before application work. Specification: - Assay (dried basis): 98.0–101.0% (HPLC-RI) - Appearance: White crystalline powder - Moisture: ≤0.5% - pH (5% solution): 4.0–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 60 mesh - Bulk density: 0.50–0.80 g/mL - Other sugars: ≤1.0% (HPLC) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Flavour systems, Bakery, Confectionery, Beverages, Sauces - Sweetness: 40–50% of sucrose, indicative - Taste: Mild sweetness with a slight woody or cereal note at higher doses; used as a flavour precursor as well as a sweetener. - Solubility: Freely soluble in water; clean solutions at use levels. #### Isomaltulose URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/isomaltulose/ Identity: 6-O-α-D-glucopyranosyl-D-fructose, crystalline Formula: C₁₂H₂₂O₁₁ CAS: 13718-94-0 Summary: A crystalline isomaltulose for slow-release carbohydrate and sugar replacement, with a sucrose-like taste, low hygroscopicity and a clear distinction from isomalt. Specification: - Isomaltulose (dry basis): ≥98.0% (HPLC-RI) - Appearance: White crystalline powder - Moisture: ≤0.5% - pH (10% solution): 4.5–7.0 - Solubility: Soluble in water; low hygroscopicity - Particle size: ≥95% through 60 mesh - Bulk density: 0.55–0.85 g/mL - Other sugars: ≤1.0% (HPLC-RI) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Bakery, Confectionery, Sports nutrition, Dairy - Sweetness: 40–50% of sucrose, indicative - Taste: Clean, sucrose-like sweetness with no strong cooling; the body is closer to sugar than a high-intensity sweetener. - Solubility: Soluble in water; low hygroscopicity and a clean solution. #### Crystalline Fructose URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/crystalline-fructose/ Identity: D-Fructose, crystalline powder Formula: C₆H₁₂O₆ CAS: 57-48-7 Summary: A 99.5% crystalline fructose for beverages, bakery and confectionery, with a high sweetness, humectancy and browning behaviour stated before the trial. Specification: - Fructose (dry basis): ≥99.5% (HPLC-RI) - Appearance: White crystalline powder - Moisture: ≤0.5% - pH (10% solution): 4.0–6.5 - Solubility: Freely soluble in water - Particle size: ≥95% through 60 mesh - Bulk density: 0.55–0.85 g/mL - Other sugars: ≤0.5% (HPLC-RI) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Bakery, Confectionery, Dairy, Tabletop - Sweetness: 130–180% of sucrose at equal solids, depending on the matrix - Taste: Clean, fast-onset sweetness with a strong body; at high dose it can taste syrupy. - Solubility: Freely soluble in water; hygroscopic and humectant. ### Soluble Fibres & Prebiotic Carbohydrates Fibre is an analytical result and a process ingredient at the same time. Inulin and oligofructose are measured by different methods and carry different sweetness; GOS and XOS differ in viscosity, osmolarity and stability; polydextrose and resistant dextrin are chosen for sugar replacement and bulk rather than sweetness. This range is built around the fibre method, the degree of polymerisation and the processing constraints. #### Inulin URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/inulin/ Identity: Inulin, extracted chicory root fibre Formula: (C₆H₁₀O₅)n CAS: 9005-80-5 Summary: A chicory inulin for fibre enrichment, sugar replacement and body, specified by fibre content, degree of polymerisation and the sweetness that comes with the shorter chains. Specification: - Inulin (dry basis): ≥90.0% (HPLC-RI) - Dietary fibre: ≥90.0% (AOAC 997.08 or equivalent) - Degree of polymerisation: DP 2–60, average 10–12 - Appearance: White to off-white powder - Moisture: ≤5.0% - pH (10% solution): 4.5–7.0 - Solubility: Soluble in water; viscosity depends on chain length - Particle size: ≥95% through 80 mesh - Bulk density: 0.40–0.70 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy, Bakery, Confectionery, Supplements - Sweetness: 10% of sucrose, indicative for standard inulin; higher for oligofructose - Taste: Mild sweetness with a clean, slightly creamy body; at high dose it can add a faint vegetal note. - Solubility: Soluble in water; longer-chain inulin builds viscosity and shorter chains are more soluble and sweeter. #### Fructooligosaccharides (FOS) URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/fructooligosaccharides/ Identity: Fructooligosaccharide powder or syrup Formula: (C₆H₁₀O₅)n, n = 2–8 CAS: 308066-66-2 Summary: A short-chain fructooligosaccharide for a clean, soluble fibre and mild sweetness in beverages, dairy and supplements, with the sugar profile stated. Specification: - FOS (dry basis): ≥95.0% (HPLC-RI) - Dietary fibre: ≥95.0% (AOAC 997.08 or equivalent) - Degree of polymerisation: DP 2–8 - Appearance: White to off-white powder - Moisture: ≤5.0% - pH (10% solution): 4.5–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Bulk density: 0.40–0.70 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy, Supplements, Confectionery, Bakery - Sweetness: 30–50% of sucrose, indicative - Taste: Clean, mild sweetness with a slight fruity note; less body than inulin and easier in a clear beverage. - Solubility: Freely soluble in water; low viscosity at use levels. #### Galactooligosaccharides (GOS) URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/galactooligosaccharides/ Identity: Galactooligosaccharide syrup or powder Formula: Galacto-oligosaccharide mixture CAS: 6587-31-1 Summary: A GOS syrup or powder for soluble fibre and body in beverages, dairy and supplements, with the DP profile, lactose figure and fibre method declared. Specification: - GOS (dry basis): ≥70.0% (HPLC-RI) - Dietary fibre: ≥70.0% (AOAC 2009.01 or equivalent) - Degree of polymerisation: DP 2–8 - Lactose: ≤10.0% (HPLC-RI) - Appearance: Colourless to light yellow syrup or white powder - Moisture: ≤5.0% (powder); 25% solids in syrup - pH (10% solution): 4.0–7.0 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh (powder) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum; 250 kg drum for syrup - Applications: Beverages, Dairy, Supplements, Infant nutrition, Bakery - Sweetness: 20–30% of sucrose, indicative - Taste: Mild, clean sweetness with a slightly milky note; useful in dairy and beverage systems. - Solubility: Freely soluble in water; low viscosity and a clean solution at use levels. #### Xylooligosaccharides (XOS) URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/xylooligosaccharides/ Identity: Xylooligosaccharide powder or syrup Formula: (C₅H₈O₄)n CAS: — Summary: A XOS powder or syrup for soluble fibre in beverages and supplements, specified by the XOS content, DP profile and low viscosity that make it easy to formulate. Specification: - XOS (dry basis): ≥95.0% (HPLC-RI) - Dietary fibre: ≥85.0% (AOAC 2009.01 or equivalent) - Degree of polymerisation: DP 2–7 - Appearance: White to light yellow powder - Moisture: ≤5.0% - pH (10% solution): 3.5–6.5 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Ash: ≤0.5% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Supplements, Dairy, Confectionery, Bakery - Sweetness: 20–30% of sucrose, indicative - Taste: Mild, clean sweetness with a slight woody note at high dose; low viscosity makes it easy in beverages. - Solubility: Freely soluble in water; low viscosity and a clean solution. #### Polydextrose URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/polydextrose/ Identity: Polydextrose, amorphous powder or syrup Formula: Glucose polymer with sorbitol and citric acid CAS: 68424-04-4 Summary: A polydextrose for sugar replacement, fibre enrichment and body in bakery, confectionery and beverages, with the fibre method and the physical data stated. Specification: - Polydextrose (dry basis): ≥90.0% (HPLC-RI) - Dietary fibre: ≥90.0% (AOAC 2009.01 or equivalent) - Appearance: White to cream-coloured powder - Moisture: ≤3.0% - pH (10% solution): 3.0–6.0 - Solubility: Freely soluble in water; low viscosity - Particle size: ≥95% through 80 mesh - Bulk density: 0.40–0.70 g/mL - Glucose: ≤4.0% (HPLC-RI) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Bakery, Confectionery, Beverages, Dairy, Supplements - Sweetness: Very low, essentially non-sweet; used for bulk and body - Taste: Almost no sweetness, with a clean, slightly tart note; it adds body and humectancy rather than sweetness. - Solubility: Freely soluble in water; low viscosity and a clean, slightly tart taste. #### Resistant Dextrin URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/resistant-dextrin/ Identity: Resistant dextrin, soluble fibre powder or syrup Formula: Indigestible dextrin CAS: — Summary: A resistant dextrin for soluble fibre, low viscosity and clean taste in beverages and supplements, specified by fibre content and the analytical method behind it. Specification: - Dietary fibre: ≥85.0% (AOAC 2009.01) - Resistant dextrin: ≥85.0% (HPLC-RI) - Appearance: White to light yellow powder - Moisture: ≤5.0% - pH (10% solution): 3.0–6.0 - Solubility: Freely soluble in water; low viscosity - Particle size: ≥95% through 80 mesh - Bulk density: 0.40–0.70 g/mL - Glucose: ≤5.0% (HPLC-RI) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 1–7 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Supplements, Bakery, Dairy, Confectionery - Sweetness: 10% of sucrose, indicative - Taste: Clean, almost neutral with a very mild sweetness; useful where the fibre should not change the flavour. - Solubility: Freely soluble in water; low viscosity, clean solution. #### Isomaltooligosaccharide (IMO) 90% URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/isomaltooligosaccharide/ Identity: Isomaltooligosaccharide powder or syrup Formula: (C₆H₁₀O₅)n, α-1,6-linked CAS: — Summary: An IMO 90% powder or syrup for soluble fibre, body and mild sweetness, with the fibre method, sugar profile and physical data stated before the trial. Specification: - IMO (dry basis): ≥90.0% (HPLC-RI) - Dietary fibre: ≥85.0% (AOAC 2009.01) - Appearance: White to light yellow powder or syrup - Moisture: ≤5.0% (powder) - pH (10% solution): 4.0–6.5 - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Ash: ≤0.5% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy, Bakery, Supplements, Confectionery - Sweetness: 40–60% of sucrose, indicative - Taste: Mild, clean sweetness with a slight body; less sweet than sucrose. - Solubility: Freely soluble in water; low viscosity at use levels. #### Stachyose 98% URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/stachyose/ Identity: Stachyose tetrahydrate, crystalline powder Formula: C₂₄H₄₂O₂₁ CAS: 470-55-3 Summary: A 98% stachyose for soluble oligosaccharide applications, with the soybean source, hydrate and sugar profile stated. Specification: - Stachyose (dry basis): ≥98.0% (HPLC-RI) - Appearance: White crystalline powder - Moisture: ≤5.0% - pH (10% solution): 4.5–7.0 - Solubility: Soluble in water - Particle size: ≥95% through 80 mesh - Ash: ≤0.3% - Other sugars: ≤1.0% (HPLC-RI) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Supplements, Dairy, Confectionery, Bakery - Sweetness: 20–30% of sucrose, indicative - Taste: Mild sweetness with a clean finish; at high dose a slight beany note can appear. - Solubility: Soluble in water; low viscosity at use levels. #### Maltooligosaccharide 90% URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/maltooligosaccharide/ Identity: Maltooligosaccharide powder or syrup Formula: (C₆H₁₀O₅)n, α-1,4-linked, n = 2–7 CAS: — Summary: A maltooligosaccharide for mild sweetness and body, with the DP profile, sugar content and fibre method stated for the exact grade. Specification: - Maltooligosaccharide (dry basis): ≥90.0% (HPLC-RI) - Degree of polymerisation: DP 2–7 - Dietary fibre: ≥80.0% (AOAC 2009.01) - Appearance: White to light yellow powder or syrup - Moisture: ≤5.0% (powder) - pH (10% solution): 4.0–6.5 - Solubility: Freely soluble in water - Ash: ≤0.5% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy, Bakery, Supplements, Confectionery - Sweetness: 40–60% of sucrose, indicative - Taste: Mild, clean sweetness with a little body; less sweet than sucrose. - Solubility: Freely soluble in water; low viscosity. #### Acacia Gum (Gum Arabic) URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/acacia-gum/ Identity: Spray-dried acacia gum powder Formula: Acacia senegal polysaccharide CAS: 9000-01-5 Summary: A spray-dried acacia gum for soluble fibre, emulsion stability and low viscosity, with the fibre method and viscosity data stated. Specification: - Dietary fibre: ≥85.0% (AOAC 2009.01) - Appearance: White to cream-coloured powder - Moisture: ≤8.0% - pH (10% solution): 4.0–6.5 - Solubility: Soluble in water; low viscosity - Particle size: ≥95% through 80 mesh - Ash: ≤4.0% - Viscosity: Specified for the grade - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy, Bakery, Confectionery, Supplements - Sweetness: <5% of sucrose; essentially non-sweet - Taste: Almost neutral with a faint gum note; used for body and emulsion stability, not sweetness. - Solubility: Soluble in water; low viscosity even at high solids. #### Partially Hydrolyzed Guar Gum (PHGG) URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/partially-hydrolyzed-guar-gum/ Identity: Partially hydrolysed guar gum, spray-dried powder Formula: Partially hydrolysed guar galactomannan CAS: 9000-30-0 (guar gum basis) Summary: A partially hydrolyzed guar gum for soluble fibre without viscosity, with the fibre method, DP profile and low-viscosity behaviour stated. Specification: - Dietary fibre: ≥85.0% (AOAC 2009.01) - Appearance: White to off-white powder - Moisture: ≤6.0% - pH (1% solution): 4.0–7.0 - Solubility: Soluble in water; low viscosity - Particle size: ≥95% through 80 mesh - Ash: ≤1.0% - Viscosity: Low; specified for the grade - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Dairy, Supplements, Bakery, Confectionery - Sweetness: <5% of sucrose; essentially non-sweet - Taste: Clean, almost neutral; useful where the fibre must not change the flavour or the viscosity. - Solubility: Soluble in water; low viscosity compared with native guar gum. #### Oat Beta-Glucan 70% URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/oat-beta-glucan/ Identity: Oat beta-glucan concentrate, 70% beta-glucan Formula: (1→3)(1→4)-β-D-glucan CAS: — Summary: A 70% oat beta-glucan concentrate for soluble fibre and viscosity, with the beta-glucan method, protein and ash data. Specification: - Beta-glucan: ≥70.0% (AOAC 995.16) - Dietary fibre: ≥75.0% (AOAC 2009.01) - Appearance: Off-white to light brown powder - Moisture: ≤6.0% - pH (1% suspension): 5.0–7.5 - Solubility: Dispersible in water; viscosity depends on the grade - Particle size: ≥95% through 80 mesh - Protein: ≤8.0% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Bakery, Dairy, Supplements, Cereal - Sweetness: Not sweet at use levels - Taste: Mild cereal note; used for fibre and body, not sweetness. - Solubility: Dispersible in water; builds viscosity and can form a gel at higher concentrations. #### Pectin (HM/LM) URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/pectin/ Identity: High-methoxyl or low-methoxyl pectin powder Formula: Partially methylated polygalacturonic acid CAS: 9000-69-5 Summary: A high-methoxyl or low-methoxyl pectin for gelling, body and soluble fibre, with the degree of esterification stated. Specification: - Galacturonic acid: ≥65.0% (dry basis) - Degree of esterification: HM 55–75%; LM 20–45% - Dietary fibre: ≥65.0% (AOAC 2009.01) - Appearance: White to light brown powder - Moisture: ≤8.0% - pH (1% solution): 3.0–5.0 - Solubility: Soluble in water; gelation depends on the DE and the calcium - Particle size: ≥95% through 80 mesh - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Jams and fruit, Beverages, Confectionery, Dairy, Bakery - Sweetness: Not sweet at use levels - Taste: Mild, slightly tart; used for gel, body and fibre, not sweetness. - Solubility: Soluble in water; HM pectin gels with acid and sugar, LM pectin with calcium. #### Lactulose 70% Syrup URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/lactulose/ Identity: Lactulose 70% syrup Formula: C₁₂H₂₂O₁₁ CAS: 4618-18-2 Summary: A lactulose 70% syrup for food and specialty carbohydrate use, with the solids, sugar profile and viscosity stated. Specification: - Lactulose (dry basis): ≥70.0% (HPLC-RI) - Solids: 70.0–75.0% (refractometer) - Appearance: Colourless to light yellow syrup - pH (10% solution): 3.0–5.0 - Ash: ≤0.1% - Solubility: Miscible with water - Viscosity: Specified at 25 °C - Other sugars: ≤5.0% (HPLC-RI) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Specialty foods, Supplements, Confectionery, Dairy, Beverages - Sweetness: 30–50% of sucrose, indicative - Taste: Mild sweetness with body; at higher doses a slight caramel note. - Solubility: Miscible with water; supplied as a syrup. #### Soybean Oligosaccharides 60% URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/soybean-oligosaccharides/ Identity: Soybean oligosaccharide powder or syrup Formula: Soybean oligosaccharide mixture CAS: — Summary: A soybean oligosaccharide with a defined stachyose and raffinose profile for soluble fibre and body, with the soy source and sugar profile stated. Specification: - Total oligosaccharides: ≥60.0% (HPLC-RI) - Stachyose: ≥20.0% (HPLC-RI) - Raffinose: ≥10.0% (HPLC-RI) - Appearance: White to light yellow powder or syrup - Moisture: ≤5.0% (powder) - pH (10% solution): 4.5–7.0 - Solubility: Soluble in water - Ash: ≤0.5% - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Supplements, Dairy, Confectionery, Bakery - Sweetness: 20–30% of sucrose, indicative - Taste: Mild sweetness with a slight beany note; the soy source matters. - Solubility: Soluble in water; low viscosity. #### Raffinose 98% URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/raffinose/ Identity: Raffinose pentahydrate, crystalline powder Formula: C₁₈H₃₂O₁₆ CAS: 512-69-6 Summary: A 98% raffinose for soluble oligosaccharide and specialty carbohydrate use, with the hydrate and sugar profile stated. Specification: - Raffinose (dry basis): ≥98.0% (HPLC-RI) - Appearance: White crystalline powder - Moisture: ≤5.0% - pH (10% solution): 4.5–7.0 - Solubility: Soluble in water - Particle size: ≥95% through 80 mesh - Ash: ≤0.3% - Other sugars: ≤1.0% (HPLC-RI) - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Supplements, Dairy, Confectionery, Bakery - Sweetness: 20–30% of sucrose, indicative - Taste: Mild sweetness with a clean finish; the oligosaccharide note is subtle. - Solubility: Soluble in water; a clean, low-viscosity solution. ### Sweetener Blends & Systems A blend is a formula, not a shortcut. The ratio, the carrier, the homogeneity and the assay of each active are part of the specification. This range covers the standard ratios we can quote from stock and the custom systems that are developed against a written brief. The published ratio is a starting point; the final ratio is confirmed after a matrix trial. #### Stevia-Erythritol Blend 1% URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/stevia-erythritol-blend/ Identity: Spray-dried or dry-blended steviol glycosides on erythritol Formula: Steviol glycosides 1% on erythritol CAS: — Summary: A 1% steviol glycoside blend on erythritol for tabletop, beverages and reduced-sugar foods, specified by the active content, carrier and homogeneity. Specification: - Steviol glycosides: 0.9–1.1% (HPLC-UV) - Rebaudioside A: 0.5–0.8% (HPLC-UV) - Erythritol: ≥98.0% (HPLC-RI) - Appearance: White to off-white powder - Moisture: ≤0.5% - Solubility: Soluble in water - Particle size: ≥95% through 60 mesh - Homogeneity: Specified by the blend protocol - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Tabletop, Beverages, Dairy alternatives, Confectionery, Supplements - Sweetness: 3–5 × sucrose, indicative - Taste: Sweet with the cooling effect of erythritol and a light stevia note; cleaner at lower doses. - Solubility: Soluble in water; the erythritol dissolves endothermically. #### Monk Fruit-Erythritol Blend 1% URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-erythritol-blend/ Identity: Mogroside V on erythritol, dry blend Formula: Mogroside V 1% on erythritol CAS: — Summary: A 1% Mogroside V blend on erythritol for a clean, fruit-forward sweetness with bulk, specified by the active content, carrier and homogeneity. Specification: - Mogroside V: 0.9–1.1% (HPLC) - Total mogrosides: ≥1.2% (HPLC) - Erythritol: ≥98.0% (HPLC-RI) - Appearance: White to off-white powder - Moisture: ≤0.5% - Solubility: Soluble in water - Particle size: ≥95% through 60 mesh - Homogeneity: Specified by the blend protocol - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Tabletop, Beverages, Dairy alternatives, Confectionery, Supplements - Sweetness: 2–4 × sucrose, indicative - Taste: Clean, fruit-forward sweetness with erythritol cooling; less liquorice than stevia. - Solubility: Soluble in water; the erythritol dissolves endothermically. #### Sucralose-Ace-K Blend 25/75 URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/sucralose-acesulfame-blend/ Identity: Sucralose and acesulfame potassium, 25:75 dry blend Formula: Sucralose 25% and acesulfame potassium 75% CAS: — Summary: A 25:75 sucralose-Ace-K blend for a rounded high-intensity sweetness, specified by each active, the ratio and the homogeneity. Specification: - Sucralose: 24.5–25.5% (HPLC) - Acesulfame potassium: 74.5–75.5% (HPLC) - Appearance: White powder - Moisture: ≤1.0% - Solubility: Freely soluble in water - Particle size: ≥95% through 80 mesh - Homogeneity: Specified by the blend protocol - Bulk density: 0.50–0.80 g/mL - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Tabletop, Dairy, Confectionery, Chewing gum - Sweetness: 250–300 × sucrose, indicative - Taste: Fast onset from the Ace-K with a rounder tail from the sucralose; the blend reduces the metallic linger of Ace-K alone. - Solubility: Freely soluble in water; clear at use levels. #### Allulose-Stevia Blend 5/95 URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/allulose-stevia-blend/ Identity: Steviol glycosides on allulose, 5:95 dry blend Formula: Rebaudioside A 5% on allulose CAS: — Summary: A 5:95 allulose-stevia blend for a sugar-like body with high-intensity sweetness, specified by the active content, carrier and homogeneity. Specification: - Steviol glycosides: 4.5–5.5% (HPLC-UV) - Rebaudioside A: ≥4.0% (HPLC-UV) - Allulose: ≥94.0% (HPLC-RI) - Appearance: White to off-white powder - Moisture: ≤1.0% - Solubility: Freely soluble in water - Particle size: ≥95% through 60 mesh - Homogeneity: Specified by the blend protocol - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Bakery, Dairy alternatives, Confectionery, Tabletop - Sweetness: 15–20 × sucrose, indicative - Taste: Sweet with allulose body and a stevia top note; the blend can brown like a sugar. - Solubility: Freely soluble in water; allulose adds body and browning. #### Monk Fruit-Allulose Blend 2/98 URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-allulose-blend/ Identity: Mogroside V on allulose, 2:98 dry blend Formula: Mogroside V 2% on allulose CAS: — Summary: A 2:98 monk fruit-allulose blend for a clean, fruit-forward sweetness with allulose body, specified by the active content and homogeneity. Specification: - Mogroside V: 1.8–2.2% (HPLC) - Total mogrosides: ≥2.4% (HPLC) - Allulose: ≥97.0% (HPLC-RI) - Appearance: White to off-white powder - Moisture: ≤1.0% - Solubility: Freely soluble in water - Particle size: ≥95% through 60 mesh - Homogeneity: Specified by the blend protocol - Heavy metals: Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg - Microbiology: APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent - MOQ: 1 kg - Lead time: 3–10 days - Packaging: 1 kg foil pouch; 25 kg fiber drum - Applications: Beverages, Bakery, Dairy alternatives, Confectionery, Tabletop - Sweetness: 8–12 × sucrose, indicative - Taste: Clean, fruit-forward sweetness with allulose body; less stevia linger. - Solubility: Freely soluble in water; allulose adds body and browning. ## Testing panel ### Identity and assay - Specific marker assay by HPLC or HPLC-RI, with the chromatographic method named - Identity by retention time, IR spectrum or mass confirmation where the grade requires it - Related substances and breakdown products relevant to the sweetener family - Moisture by Karl Fischer or loss on drying, stated on the basis used ### Physical and process - Appearance, colour and odour - Particle size distribution and bulk density - Solubility, clarity of solution and pH where relevant - Sweetness equivalence and taste notes at a stated use level ### Contaminants - Lead, arsenic, cadmium and mercury by ICP-MS - Microbiology: APC, yeast and mould, E. coli, Salmonella - Residual solvents matched to the purification system - Foreign matter and ash where the grade requires it ## Documents shipped with a lot ### Certificate of analysis Batch-specific results for identity, assay, sweetness-relevant impurities, moisture, particle size, heavy metals and microbiology, with the method named against each parameter. ### Technical data sheet Chemical form, CAS number, specification ranges, sweetness versus sucrose, solubility, bulk density, recommended storage and the grades available for the same sweetener. ### Safety data sheet A 16-section SDS issued against the exact grade supplied, in the format your EHS team already files. ### Allergen, GMO and origin statements Declarations covering the major allergen list, gluten, animal-derived inputs, GMO status and the manufacturing site, signed for the batch. ### Residual solvent and contaminant statements The solvent system used in purification, plus heavy-metal and microbiological results against the destination-market limits. ### Specification comparison A line-by-line comparison of our specification against the one you sent, including where we cannot match and why. ## Technical documents ### 01 Steviol Glycosides 95%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/steviol-glycosides/coa/ Reviewed: 2026-11-20 Steviol Glycosides 95% (CAS 57817-89-7 (stevioside)) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineSteviol Glycosides 95% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection at 210 nm. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Steviol Glycosides 95% | | Parameter | Specification | Total steviol glycosides | ≥95.0% (HPLC) | Rebaudioside A | 40.0–60.0% (HPLC) | Stevioside | 20.0–35.0% (HPLC) | Rebaudioside C | ≤10.0% (HPLC) | Appearance | White to off-white powder | Moisture | ≤5.0% | pH (1% solution) | 4.5–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.30–0.60 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Steviol Glycosides 95% the identity evidence used for release is: - HPLC retention times against stevioside and Reb A reference standards - Total glycoside mass balance, not only the Reb A peak - Reb A : stevioside ratio and the rebaudioside C figure - IR spectrum and appearance against the reference standard HPLC retention times against stevioside and Reb A reference standards is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection at 210 nm reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Steviol Glycosides 95% the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Steviol Glycosides 95% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Steviol Glycosides 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Steviol Glycosides 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Steviol Glycosides 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Steviol Glycosides 95% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/steviol-glycosides/grades/ Reviewed: 2026-11-20 Steviol Glycosides 95% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Steviol Glycosides 95% is no exception: Steviol Glycosides 95% and Rebaudioside A 98% can share an assay and still behave differently in the line. ## The grade map Steviol Glycosides 95% grades | | Grade | Best fit | What changes | Steviol Glycosides 95% | General beverage, tabletop and food use | Balanced glycoside profile at the lowest cost per sweetness unit | Rebaudioside A 98% | Cleaner taste, lower stevioside | Higher purity, lower linger, higher cost | Rebaudioside M 95% | Premium clean-label beverages | Faster onset and less aftertaste; highest cost | Organic grade | Organic-certified finished products | Requires organic certificate and lot traceability ## Sweetness and taste The indicative sweetness is 200–300 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Sweet with a slower onset and a liquorice-like linger at higher doses; mouthfeel thins in water unless a bulk sweetener is added. The use level is 0.01–0.08% in ready-to-drink beverages, depending on target sucrose equivalence. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; solutions are clear at typical use levels and remain stable across beverage pH. Moderately hygroscopic; store sealed below 25 °C and 60% RH. ## The grade decision The level-four page for this product compares Total steviol glycosides ≥95% with Reb A ≥98%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Total steviol glycosides vs Reb A: what the percentage is measuring A total glycoside figure sums a family of molecules with different taste curves; a Reb A figure names one of them. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Steviol Glycosides 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Steviol Glycosides 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Steviol Glycosides 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Steviol Glycosides 95% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/steviol-glycosides/stability/ Reviewed: 2026-11-20 Steviol Glycosides 95% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderately hygroscopic; store sealed below 25 °C and 60% RH. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry blends; pasteurisation causes little loss, but taste drift and hydrolysis should be measured at the target pH and hold time. Typically stable from pH 3 to 7. Very low pH plus prolonged heat increases hydrolysis of the glycoside ester linkages. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Steviol Glycosides 95% is added at 0.01–0.08% in ready-to-drink beverages, depending on target sucrose equivalence. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; solutions are clear at typical use levels and remain stable across beverage pH. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Steviol Glycosides 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Steviol Glycosides 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Steviol Glycosides 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Steviol Glycosides 95%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/steviol-glycosides/moq/ Reviewed: 2026-11-20 Steviol Glycosides 95% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Steviol Glycosides 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Steviol Glycosides 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Steviol Glycosides 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Steviol Glycosides 95% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/steviol-glycosides/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Steviol Glycosides 95% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Steviol Glycosides 95% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC retention times against stevioside and Reb A reference standards - Total glycoside mass balance, not only the Reb A peak - Reb A : stevioside ratio and the rebaudioside C figure - IR spectrum and appearance against the reference standard For this grade, the primary assay is HPLC with UV detection at 210 nm. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Bulking with maltodextrin, erythritol or dextrose to reach a lower-cost 95% statement - A high-Reb A extract sold as generic stevia without declaring the glycoside profile - Stevioside-heavy material presented as a clean-taste grade - Undeclared organic solvent residues from a low-quality purification step None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Steviol Glycosides 95%, the relevant identity format is Total steviol glycosides ≥95%, Reb A 40–60%, stevioside 20–35%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Steviol Glycosides 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Steviol Glycosides 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Steviol Glycosides 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Total steviol glycosides vs Reb A: what the percentage is measuring URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/steviol-glycosides/grades/total-glycosides-vs-reb-a/ Reviewed: 2026-11-20 Two 95% labels, two different powders is a formulation question, not a catalogue question. A total glycoside figure sums a family of molecules with different taste curves; a Reb A figure names one of them. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA total glycoside figure sums a family of molecules with different taste curves; a Reb A figure names one of them. ## The two options Total steviol glycosides vs Reb A: what the percentage is measuring | | Option | What it is | Option A | Total steviol glycosides ≥95%: a family assay that includes Reb A, stevioside, Reb C and minor glycosides. | Option B | Reb A ≥98%: a single-glycoside specification with a defined purity and a much smaller stevioside fraction. ## Taste and sweetness The published sweetness for Steviol Glycosides 95% is 200–300 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Sweet with a slower onset and a liquorice-like linger at higher doses; mouthfeel thins in water unless a bulk sweetener is added. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Total steviol glycosides ≥95%: a family assay that includes Reb A, stevioside, Reb C and minor glycosides. Reb A ≥98%: a single-glycoside specification with a defined purity and a much smaller stevioside fraction. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; solutions are clear at typical use levels and remain stable across beverage pH. Stable in dry blends; pasteurisation causes little loss, but taste drift and hydrolysis should be measured at the target pH and hold time. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Steviol Glycosides 95%, Rebaudioside A 98%, Rebaudioside M 95%, Organic grade. The primary specification is ≥95.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; solutions are clear at typical use levels and remain stable across beverage pH. 0.01–0.08% in ready-to-drink beverages, depending on target sucrose equivalence is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the application and the process, then confirm the particle size, carrier and use level in a matrix trial. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Steviol Glycosides 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Steviol Glycosides 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Steviol Glycosides 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Rebaudioside A 98%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-a/coa/ Reviewed: 2026-11-20 Rebaudioside A 98% (CAS 58543-16-1) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineRebaudioside A 98% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection at 210 nm. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Rebaudioside A 98% | | Parameter | Specification | Rebaudioside A | ≥98.0% (HPLC) | Total steviol glycosides | ≥99.0% (HPLC) | Stevioside | ≤1.0% (HPLC) | Rebaudioside C | ≤0.5% (HPLC) | Appearance | White to off-white powder | Moisture | ≤3.0% | pH (1% solution) | 4.5–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.30–0.60 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Rebaudioside A 98% the identity evidence used for release is: - HPLC against a certified Reb A reference standard - Stevioside and Reb C by the same gradient, to confirm the purity figure - Mass balance of the glycoside peaks - IR spectrum compared with the reference HPLC against a certified Reb A reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection at 210 nm reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Rebaudioside A 98% the moisture limit is ≤3.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Rebaudioside A 98% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Rebaudioside A 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside A 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside A 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Rebaudioside A 98% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-a/grades/ Reviewed: 2026-11-20 Rebaudioside A 98% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Rebaudioside A 98% is no exception: Reb A 98% powder and Reb A 98% granular can share an assay and still behave differently in the line. ## The grade map Rebaudioside A 98% grades | | Grade | Best fit | What changes | Reb A 98% powder | Beverages, tabletop, dairy | Standard clean-taste grade | Reb A 98% granular | Dry mixes and tabletop | Better flow, lower dust | Reb A 95% | Cost-sensitive food use | Higher stevioside fraction; taste test required | Organic Reb A | Organic-certified products | Certificate and lot traceability required ## Sweetness and taste The indicative sweetness is 200–300 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Cleaner than a total glycoside grade, with a faster onset and less liquorice linger; a sweet aftertaste remains at high dose. The use level is 0.01–0.06% in beverages, depending on target sucrose equivalence and the blend. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; clear at use levels and compatible with typical beverage processing. Moderately hygroscopic; reseal the liner after use and store below 25 °C. ## The grade decision The level-four page for this product compares Reb A 98% with Reb M 95%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Reb A 98% vs Reb M 95%: which stevia grade fits the brief Reb A and Reb M are different glycosides. A higher Reb A percentage does not buy the cleaner, faster sweetness of Reb M. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Rebaudioside A 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside A 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside A 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Rebaudioside A 98% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-a/stability/ Reviewed: 2026-11-20 Rebaudioside A 98% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderately hygroscopic; reseal the liner after use and store below 25 °C. The specification limits moisture to ≤3.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry blends and through typical pasteurisation; prolonged acid plus heat should be tested in the finished matrix. Stable across pH 3–7 in normal beverage use; hydrolysis is measurable at very low pH and high temperature. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Rebaudioside A 98% is added at 0.01–0.06% in beverages, depending on target sucrose equivalence and the blend. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; clear at use levels and compatible with typical beverage processing. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Rebaudioside A 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside A 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside A 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Rebaudioside A 98%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-a/moq/ Reviewed: 2026-11-20 Rebaudioside A 98% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Rebaudioside A 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside A 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside A 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Rebaudioside A 98% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-a/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Rebaudioside A 98% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Rebaudioside A 98% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC against a certified Reb A reference standard - Stevioside and Reb C by the same gradient, to confirm the purity figure - Mass balance of the glycoside peaks - IR spectrum compared with the reference For this grade, the primary assay is HPLC with UV detection at 210 nm. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A 95% total glycoside powder sold as 98% Reb A - Reb A blended with stevioside to reduce cost - Maltodextrin carrier not declared on the specification - Undeclared Reb M or enzymatic glycoside material presented as plant-extracted Reb A None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Rebaudioside A 98%, the relevant identity format is Reb A ≥98%, total steviol glycosides ≥99%, stevioside ≤1%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Rebaudioside A 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside A 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside A 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Reb A 98% vs Reb M 95%: which stevia grade fits the brief URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-a/grades/reb-a-98-vs-reb-m-95/ Reviewed: 2026-11-20 Purity is not the same as taste is a formulation question, not a catalogue question. Reb A and Reb M are different glycosides. A higher Reb A percentage does not buy the cleaner, faster sweetness of Reb M. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineReb A and Reb M are different glycosides. A higher Reb A percentage does not buy the cleaner, faster sweetness of Reb M. ## The two options Reb A 98% vs Reb M 95%: which stevia grade fits the brief | | Option | What it is | Option A | Reb A 98%: the established stevia grade, lower cost, clean at moderate dose, with a recognizable stevia tail. | Option B | Reb M 95%: a minor glycoside with a faster onset, cleaner finish and a materially higher cost per sweetness unit. ## Taste and sweetness The published sweetness for Rebaudioside A 98% is 200–300 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Cleaner than a total glycoside grade, with a faster onset and less liquorice linger; a sweet aftertaste remains at high dose. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Reb A 98%: the established stevia grade, lower cost, clean at moderate dose, with a recognizable stevia tail. Reb M 95%: a minor glycoside with a faster onset, cleaner finish and a materially higher cost per sweetness unit. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; clear at use levels and compatible with typical beverage processing. Stable in dry blends and through typical pasteurisation; prolonged acid plus heat should be tested in the finished matrix. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Reb A 98% powder, Reb A 98% granular, Reb A 95%, Organic Reb A. The primary specification is ≥98.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; clear at use levels and compatible with typical beverage processing. 0.01–0.06% in beverages, depending on target sucrose equivalence and the blend is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision For a cost-sensitive tabletop or a beverage where stevia is already accepted, Reb A 98% is the rational default. For a premium drink where the sweetness tail is the problem, test Reb M against Reb A at the same sucrose equivalence before changing the specification. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Rebaudioside A 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside A 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside A 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Rebaudioside M 95%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-m/coa/ Reviewed: 2026-11-20 Rebaudioside M 95% (CAS 1220616-44-3) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineRebaudioside M 95% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection at 210 nm. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Rebaudioside M 95% | | Parameter | Specification | Rebaudioside M | ≥95.0% (HPLC) | Total steviol glycosides | ≥98.0% (HPLC) | Rebaudioside A | ≤2.0% (HPLC) | Stevioside | ≤0.5% (HPLC) | Appearance | White to off-white powder | Moisture | ≤3.0% | pH (1% solution) | 4.5–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.30–0.60 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Rebaudioside M 95% the identity evidence used for release is: - HPLC against a Reb M reference standard - Reb A and stevioside by the same method - Total glycoside mass balance - IR and optical rotation where required HPLC against a Reb M reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection at 210 nm reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Rebaudioside M 95% the moisture limit is ≤3.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Rebaudioside M 95% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Rebaudioside M 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside M 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside M 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Rebaudioside M 95% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-m/grades/ Reviewed: 2026-11-20 Rebaudioside M 95% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Rebaudioside M 95% is no exception: Reb M 95% powder and Reb M 90% powder can share an assay and still behave differently in the line. ## The grade map Rebaudioside M 95% grades | | Grade | Best fit | What changes | Reb M 95% powder | Premium beverages and tabletop | Highest purity and cleanest taste | Reb M 90% powder | Cost-sensitive premium use | Higher minor glycoside fraction | Reb M liquid | Syrup and beverage lines | Carrier and solids must be declared | Reb M granular | Dry blends | Lower dust, better flow ## Sweetness and taste The indicative sweetness is 250–350 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Faster onset and cleaner finish than Reb A, with less liquorice linger; still sweet after the swallow at high dose. The use level is 0.008–0.05% in beverages, depending on the target sucrose equivalence. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; clear solution at typical beverage use levels. Moderately hygroscopic; keep the liner sealed and store below 25 °C. ## The grade decision The level-four page for this product compares Powder with Liquid. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Reb M powder vs liquid: the form decision behind the dose A liquid Reb M grade is not a different sweetener; it is the same molecule with water, a carrier and a preservative challenge. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Rebaudioside M 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside M 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside M 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Rebaudioside M 95% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-m/stability/ Reviewed: 2026-11-20 Rebaudioside M 95% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderately hygroscopic; keep the liner sealed and store below 25 °C. The specification limits moisture to ≤3.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable dry and through standard beverage pasteurisation; test the finished matrix for taste drift over shelf life. Stable across normal beverage pH; extreme acid and prolonged heat increase glycoside hydrolysis. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Rebaudioside M 95% is added at 0.008–0.05% in beverages, depending on the target sucrose equivalence. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; clear solution at typical beverage use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Rebaudioside M 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside M 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside M 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Rebaudioside M 95%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-m/moq/ Reviewed: 2026-11-20 Rebaudioside M 95% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Rebaudioside M 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside M 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside M 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Rebaudioside M 95% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-m/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Rebaudioside M 95% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Rebaudioside M 95% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC against a Reb M reference standard - Reb A and stevioside by the same method - Total glycoside mass balance - IR and optical rotation where required For this grade, the primary assay is HPLC with UV detection at 210 nm. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Reb A or a glycoside blend sold as Reb M - Fermentation-derived Reb M presented as leaf-extracted without disclosure - Carrier not declared - A 90% grade sold as 95% None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Rebaudioside M 95%, the relevant identity format is Reb M ≥95%, total steviol glycosides ≥98%, Reb A ≤2%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Rebaudioside M 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside M 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside M 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Reb M powder vs liquid: the form decision behind the dose URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rebaudioside-m/grades/reb-m-powder-vs-liquid/ Reviewed: 2026-11-20 Same glycoside, different handling is a formulation question, not a catalogue question. A liquid Reb M grade is not a different sweetener; it is the same molecule with water, a carrier and a preservative challenge. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA liquid Reb M grade is not a different sweetener; it is the same molecule with water, a carrier and a preservative challenge. ## The two options Reb M powder vs liquid: the form decision behind the dose | | Option | What it is | Option A | Powder: highest stability per kilogram, easy to weigh, no water activity penalty, but dust and dissolution time on the line. | Option B | Liquid: faster dispersion and no dust, but a lower active content, a preservative or thermal process requirement and a shorter shelf life. ## Taste and sweetness The published sweetness for Rebaudioside M 95% is 250–350 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Faster onset and cleaner finish than Reb A, with less liquorice linger; still sweet after the swallow at high dose. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Powder: highest stability per kilogram, easy to weigh, no water activity penalty, but dust and dissolution time on the line. Liquid: faster dispersion and no dust, but a lower active content, a preservative or thermal process requirement and a shorter shelf life. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; clear solution at typical beverage use levels. Stable dry and through standard beverage pasteurisation; test the finished matrix for taste drift over shelf life. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Reb M 95% powder, Reb M 90% powder, Reb M liquid, Reb M granular. The primary specification is ≥95.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; clear solution at typical beverage use levels. 0.008–0.05% in beverages, depending on the target sucrose equivalence is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose powder for dry blends, tabletop and any formula where water activity is critical. Choose liquid only when the line already handles liquid sweeteners, the preservative system is validated and the lower active content is built into the dose. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Rebaudioside M 95% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rebaudioside M 95%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rebaudioside M 95%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Monk Fruit Extract 50%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-extract/coa/ Reviewed: 2026-11-20 Monk Fruit Extract 50% (CAS 88901-36-4 (Mogroside V)) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineMonk Fruit Extract 50% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV or ELSD detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Monk Fruit Extract 50% | | Parameter | Specification | Mogroside V | ≥50.0% (HPLC) | Total mogrosides | ≥60.0% (HPLC) | Appearance | Light yellow to off-white powder | Moisture | ≤5.0% | pH (1% solution) | 4.0–7.0 | Solubility | Soluble in water; slight haze at high concentration | Particle size | ≥95% through 80 mesh | Bulk density | 0.35–0.65 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Monk Fruit Extract 50% the identity evidence used for release is: - HPLC mogroside profile with Mogroside V and total mogrosides - Sugar profile by HPLC-RI, to detect bulking - Colour and solution clarity - Botanical identity of the fruit lot in the traceability record HPLC mogroside profile with Mogroside V and total mogrosides is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV or ELSD detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Monk Fruit Extract 50% the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Monk Fruit Extract 50% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Monk Fruit Extract 50% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Extract 50%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Extract 50%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Monk Fruit Extract 50% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-extract/grades/ Reviewed: 2026-11-20 Monk Fruit Extract 50% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Monk Fruit Extract 50% is no exception: Monk Fruit 30% and Monk Fruit 50% can share an assay and still behave differently in the line. ## The grade map Monk Fruit Extract 50% grades | | Grade | Best fit | What changes | Monk Fruit 30% | Cost-sensitive food use | Lower mogroside content, more carrier solids | Monk Fruit 50% | Beverages and tabletop | Balanced taste and cost | Monk Fruit 60% | Premium clean-label drinks | Higher Mogroside V, higher cost | Organic monk fruit | Organic-certified products | Certificate and fruit traceability required ## Sweetness and taste The indicative sweetness is 150–250 × sucrose, indicative for a 50% Mogroside V extract. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, fruit-forward sweetness with a melon-like note at high dose; less liquorice linger than stevia. The use level is 0.01–0.07% in beverages, depending on target sucrose equivalence. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; a slight haze can appear at high concentration and should be checked in clear beverages. Hygroscopic; store sealed below 25 °C and 60% RH. ## The grade decision The level-four page for this product compares 30% Mogroside V with 50% Mogroside V. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Monk fruit 30% vs 50%: the extract ratio is not the sweetness A 30% and a 50% monk fruit extract can both be called monk fruit, but the Mogroside V load, the carrier and the taste are different. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Monk Fruit Extract 50% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Extract 50%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Extract 50%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Monk Fruit Extract 50% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-extract/stability/ Reviewed: 2026-11-20 Monk Fruit Extract 50% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C and 60% RH. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through typical beverage heat treatment; colour and taste should be checked after prolonged hold. Stable across pH 3–7; very low pH and long shelf life require a matrix stability test. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Monk Fruit Extract 50% is added at 0.01–0.07% in beverages, depending on target sucrose equivalence. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; a slight haze can appear at high concentration and should be checked in clear beverages. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Monk Fruit Extract 50% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Extract 50%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Extract 50%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Monk Fruit Extract 50%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-extract/moq/ Reviewed: 2026-11-20 Monk Fruit Extract 50% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Monk Fruit Extract 50% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Extract 50%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Extract 50%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Monk Fruit Extract 50% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-extract/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Monk Fruit Extract 50% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Monk Fruit Extract 50% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC mogroside profile with Mogroside V and total mogrosides - Sugar profile by HPLC-RI, to detect bulking - Colour and solution clarity - Botanical identity of the fruit lot in the traceability record For this grade, the primary assay is HPLC with UV or ELSD detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, dextrose or erythritol used to bulk a lower-mogroside extract - Stevia glycosides added to lift sweetness without declaration - A 30% extract sold as 50% - Synthetic mogrosides presented as a fruit extract None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Monk Fruit Extract 50%, the relevant identity format is Mogroside V ≥50%, total mogrosides ≥60%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Monk Fruit Extract 50% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Extract 50%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Extract 50%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Monk fruit 30% vs 50%: the extract ratio is not the sweetness URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-extract/grades/mogroside-30-vs-50/ Reviewed: 2026-11-20 Mogroside V is the number to compare is a formulation question, not a catalogue question. A 30% and a 50% monk fruit extract can both be called monk fruit, but the Mogroside V load, the carrier and the taste are different. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 30% and a 50% monk fruit extract can both be called monk fruit, but the Mogroside V load, the carrier and the taste are different. ## The two options Monk fruit 30% vs 50%: the extract ratio is not the sweetness | | Option | What it is | Option A | 30% Mogroside V: more fruit solids and carrier per unit of sweetness, lower cost per kilogram, more colour and flavour carry-over. | Option B | 50% Mogroside V: a higher active load, lower use rate, cleaner colour, and a higher cost per kilogram. ## Taste and sweetness The published sweetness for Monk Fruit Extract 50% is 150–250 × sucrose, indicative for a 50% Mogroside V extract. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, fruit-forward sweetness with a melon-like note at high dose; less liquorice linger than stevia. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process 30% Mogroside V: more fruit solids and carrier per unit of sweetness, lower cost per kilogram, more colour and flavour carry-over. 50% Mogroside V: a higher active load, lower use rate, cleaner colour, and a higher cost per kilogram. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; a slight haze can appear at high concentration and should be checked in clear beverages. Stable in dry form and through typical beverage heat treatment; colour and taste should be checked after prolonged hold. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Monk Fruit 30%, Monk Fruit 50%, Monk Fruit 60%, Organic monk fruit. The primary specification is ≥50.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; a slight haze can appear at high concentration and should be checked in clear beverages. 0.01–0.07% in beverages, depending on target sucrose equivalence is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Compare the delivered cost at sucrose equivalence and the colour in the final matrix. A 30% grade can be right for a dairy or bakery item where colour and body are welcome; a 50% grade is usually the better starting point for a clear beverage or a tabletop where colour and carrier solids are a problem. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Monk Fruit Extract 50% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Extract 50%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Extract 50%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Glycyrrhizin 98%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glycyrrhizin/coa/ Reviewed: 2026-11-20 Glycyrrhizin 98% (CAS 1405-86-3) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineGlycyrrhizin 98% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Glycyrrhizin 98% | | Parameter | Specification | Glycyrrhizic acid | ≥98.0% (HPLC) | Appearance | White to light yellow powder | Moisture | ≤6.0% | pH (1% solution) | 4.5–6.5 | Solubility | Sparingly soluble in water; soluble in alkaline solution | Particle size | ≥95% through 80 mesh | Bulk density | 0.35–0.65 g/mL | Ash | ≤1.0% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Glycyrrhizin 98% the identity evidence used for release is: - HPLC glycyrrhizic acid against a reference standard - Glycyrrhetinic acid and related triterpenes by the same method - IR spectrum - Botanical source and species in the traceability record HPLC glycyrrhizic acid against a reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Glycyrrhizin 98% the moisture limit is ≤6.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Glycyrrhizin 98% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Glycyrrhizin 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glycyrrhizin 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glycyrrhizin 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Glycyrrhizin 98% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glycyrrhizin/grades/ Reviewed: 2026-11-20 Glycyrrhizin 98% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Glycyrrhizin 98% is no exception: Glycyrrhizin 98% and Monoammonium glycyrrhizinate can share an assay and still behave differently in the line. ## The grade map Glycyrrhizin 98% grades | | Grade | Best fit | What changes | Glycyrrhizin 98% | Flavour and sweetness modification | Acid form, sparingly soluble | Monoammonium glycyrrhizinate | Water-soluble flavour systems | Salt form, easier to dissolve | Dipotassium glycyrrhizinate | Cosmetic and food systems | Different salt and molecular weight | Licorice extract 65% | Cost-sensitive flavour use | More colour and flavour background ## Sweetness and taste The indicative sweetness is 50–100 × sucrose, indicative; slow onset and a long liquorice linger. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Liquorice sweetness with a slow onset and a very long tail; at high dose the anise note dominates. The use level is 0.002–0.02% in food, depending on the category and the desired liquorice note. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Sparingly soluble in water; solubility rises with pH, which is why the salt form is often easier to formulate. Moderately hygroscopic; store sealed and away from moisture. ## The grade decision The level-four page for this product compares Glycyrrhizin (free acid) with Monoammonium glycyrrhizinate. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Glycyrrhizin vs monoammonium glycyrrhizinate: the salt decides the solution The two options are different specifications, not two names for the same drum. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Glycyrrhizin 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glycyrrhizin 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glycyrrhizin 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Glycyrrhizin 98% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glycyrrhizin/stability/ Reviewed: 2026-11-20 Glycyrrhizin 98% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderately hygroscopic; store sealed and away from moisture. The specification limits moisture to ≤6.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; in acidic solution, hydrolysis to glycyrrhetinic acid should be checked over shelf life. More soluble and stable at neutral to mildly alkaline pH; acidic beverages need a solubility and taste check. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Glycyrrhizin 98% is added at 0.002–0.02% in food, depending on the category and the desired liquorice note. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Sparingly soluble in water; solubility rises with pH, which is why the salt form is often easier to formulate. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Glycyrrhizin 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glycyrrhizin 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glycyrrhizin 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Glycyrrhizin 98%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glycyrrhizin/moq/ Reviewed: 2026-11-20 Glycyrrhizin 98% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Glycyrrhizin 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glycyrrhizin 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glycyrrhizin 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Glycyrrhizin 98% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glycyrrhizin/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Glycyrrhizin 98% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Glycyrrhizin 98% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC glycyrrhizic acid against a reference standard - Glycyrrhetinic acid and related triterpenes by the same method - IR spectrum - Botanical source and species in the traceability record For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-percentage licorice extract sold as 98% - Sucrose, maltodextrin or other sweeteners used as bulking agents - Monoammonium glycyrrhizinate sold as glycyrrhizic acid - Non-licorice triterpene material presented as glycyrrhizin None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Glycyrrhizin 98%, the relevant identity format is Glycyrrhizic acid ≥98%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Glycyrrhizin 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glycyrrhizin 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glycyrrhizin 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Glycyrrhizin vs monoammonium glycyrrhizinate: the salt decides the solution URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glycyrrhizin/grades/glycyrrhizin-vs-ammonium-glycyrrhizinate/ Reviewed: 2026-11-20 Same active, different solubility is a formulation question, not a catalogue question. The two options are different specifications, not two names for the same drum. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe two options are different specifications, not two names for the same drum. ## The two options Glycyrrhizin vs monoammonium glycyrrhizinate: the salt decides the solution | | Option | What it is | Option A | Glycyrrhizin (free acid): higher active per kilogram, sparingly soluble, needs alkaline conditions or a co-solvent. | Option B | Monoammonium glycyrrhizinate: more water-soluble, easier in a clear beverage, but a different salt name and a different molecular weight. ## Taste and sweetness The published sweetness for Glycyrrhizin 98% is 50–100 × sucrose, indicative; slow onset and a long liquorice linger. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Liquorice sweetness with a slow onset and a very long tail; at high dose the anise note dominates. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Glycyrrhizin (free acid): higher active per kilogram, sparingly soluble, needs alkaline conditions or a co-solvent. Monoammonium glycyrrhizinate: more water-soluble, easier in a clear beverage, but a different salt name and a different molecular weight. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Sparingly soluble in water; solubility rises with pH, which is why the salt form is often easier to formulate. Stable in dry form; in acidic solution, hydrolysis to glycyrrhetinic acid should be checked over shelf life. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Glycyrrhizin 98%, Monoammonium glycyrrhizinate, Dipotassium glycyrrhizinate, Licorice extract 65%. The primary specification is ≥98.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Sparingly soluble in water; solubility rises with pH, which is why the salt form is often easier to formulate. 0.002–0.02% in food, depending on the category and the desired liquorice note is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the free acid for a dry blend or an alkaline system where the active load matters. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Glycyrrhizin 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glycyrrhizin 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glycyrrhizin 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Naringin Dihydrochalcone (NDC) 98%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/naringin-dihydrochalcone/coa/ Reviewed: 2026-11-20 Naringin Dihydrochalcone (NDC) 98% (CAS 18916-17-1) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineNaringin Dihydrochalcone (NDC) 98% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Naringin Dihydrochalcone (NDC) 98% | | Parameter | Specification | Naringin dihydrochalcone | ≥98.0% (HPLC) | Naringin | ≤1.0% (HPLC) | Appearance | White to off-white powder | Moisture | ≤5.0% | pH (1% solution) | 5.0–7.0 | Solubility | Slightly soluble in water; soluble in ethanol | Particle size | ≥95% through 80 mesh | Bulk density | 0.35–0.65 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Naringin Dihydrochalcone (NDC) 98% the identity evidence used for release is: - HPLC naringin dihydrochalcone against a reference standard - Naringin and naringenin by the same method, to show conversion - UV spectrum and appearance - Residual solvent screen for the hydrogenation and purification route HPLC naringin dihydrochalcone against a reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Naringin Dihydrochalcone (NDC) 98% the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Naringin Dihydrochalcone (NDC) 98% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Naringin Dihydrochalcone (NDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Naringin Dihydrochalcone (NDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Naringin Dihydrochalcone (NDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Naringin Dihydrochalcone (NDC) 98% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/naringin-dihydrochalcone/grades/ Reviewed: 2026-11-20 Naringin Dihydrochalcone (NDC) 98% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Naringin Dihydrochalcone (NDC) 98% is no exception: NDC 98% powder and NDC 96% granular can share an assay and still behave differently in the line. ## The grade map Naringin Dihydrochalcone (NDC) 98% grades | | Grade | Best fit | What changes | NDC 98% powder | Beverages and flavour systems | High intensity, low use rate | NDC 96% granular | Dry blends | Better flow, lower dust | NDC liquid | Syrup lines | Solvent and active content must be declared | NDC 95% | Cost-sensitive flavour use | Lower active load, different dosage ## Sweetness and taste The indicative sweetness is 1,000–2,000 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Very intense sweetness with a slow onset, a long lingering tail and a cooling, slightly menthol-like note at higher doses. The use level is 0.0005–0.005% in food, depending on the category and the blend. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. Moderately hygroscopic; store sealed below 25 °C. ## The grade decision The level-four page for this product compares Naringin with NDC. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. NDC vs naringin: one letter, a different ingredient Naringin is a bitter citrus flavonoid; NDC is its hydrogenated derivative and an intense sweetener. The names are not interchangeable. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Naringin Dihydrochalcone (NDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Naringin Dihydrochalcone (NDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Naringin Dihydrochalcone (NDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Naringin Dihydrochalcone (NDC) 98% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/naringin-dihydrochalcone/stability/ Reviewed: 2026-11-20 Naringin Dihydrochalcone (NDC) 98% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderately hygroscopic; store sealed below 25 °C. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal food processing; taste modification should be rechecked after heat. Stable in mildly acidic to neutral systems; solubility rather than hydrolysis is usually the limiting factor. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Naringin Dihydrochalcone (NDC) 98% is added at 0.0005–0.005% in food, depending on the category and the blend. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Naringin Dihydrochalcone (NDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Naringin Dihydrochalcone (NDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Naringin Dihydrochalcone (NDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Naringin Dihydrochalcone (NDC) 98%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/naringin-dihydrochalcone/moq/ Reviewed: 2026-11-20 Naringin Dihydrochalcone (NDC) 98% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Naringin Dihydrochalcone (NDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Naringin Dihydrochalcone (NDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Naringin Dihydrochalcone (NDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Naringin Dihydrochalcone (NDC) 98% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/naringin-dihydrochalcone/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Naringin Dihydrochalcone (NDC) 98% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Naringin Dihydrochalcone (NDC) 98% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC naringin dihydrochalcone against a reference standard - Naringin and naringenin by the same method, to show conversion - UV spectrum and appearance - Residual solvent screen for the hydrogenation and purification route For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Naringin sold as naringin dihydrochalcone - A lower-purity extract with undeclared flavonoid background - Neohesperidin DC substituted without a label change - Carrier or diluent not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Naringin Dihydrochalcone (NDC) 98%, the relevant identity format is NDC ≥98%, naringin ≤1%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Naringin Dihydrochalcone (NDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Naringin Dihydrochalcone (NDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Naringin Dihydrochalcone (NDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 NDC vs naringin: one letter, a different ingredient URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/naringin-dihydrochalcone/grades/ndc-vs-naringin/ Reviewed: 2026-11-20 Hydrogenation is the difference is a formulation question, not a catalogue question. Naringin is a bitter citrus flavonoid; NDC is its hydrogenated derivative and an intense sweetener. The names are not interchangeable. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineNaringin is a bitter citrus flavonoid; NDC is its hydrogenated derivative and an intense sweetener. The names are not interchangeable. ## The two options NDC vs naringin: one letter, a different ingredient | | Option | What it is | Option A | Naringin: the bitter flavonoid, used for bitterness and flavour, not a sweetener at food use levels. | Option B | NDC: the dihydrochalcone, 1,000–2,000 times sweeter than sucrose, used at trace levels for sweetness and bitterness modification. ## Taste and sweetness The published sweetness for Naringin Dihydrochalcone (NDC) 98% is 1,000–2,000 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Very intense sweetness with a slow onset, a long lingering tail and a cooling, slightly menthol-like note at higher doses. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Naringin: the bitter flavonoid, used for bitterness and flavour, not a sweetener at food use levels. NDC: the dihydrochalcone, 1,000–2,000 times sweeter than sucrose, used at trace levels for sweetness and bitterness modification. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. Stable in dry form and through normal food processing; taste modification should be rechecked after heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are NDC 98% powder, NDC 96% granular, NDC liquid, NDC 95%. The primary specification is ≥98.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. 0.0005–0.005% in food, depending on the category and the blend is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Check the assay method and the naringin figure. A certificate that reports 'naringin' rather than NDC is not a sweetener specification. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Naringin Dihydrochalcone (NDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Naringin Dihydrochalcone (NDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Naringin Dihydrochalcone (NDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Thaumatin: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/thaumatin/coa/ Reviewed: 2026-11-20 Thaumatin (CAS 53850-34-3) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineThaumatin is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC protein profile and SDS-PAGE identity. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Thaumatin | | Parameter | Specification | Protein (thaumatin) | ≥95.0% (dry basis) | Appearance | White to cream-coloured powder | Moisture | ≤10.0% | pH (1% solution) | 5.0–7.5 | Solubility | Freely soluble in water | Particle size | ≥95% through 100 mesh | Bulk density | 0.25–0.55 g/mL | Ash | ≤3.0% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Thaumatin the identity evidence used for release is: - SDS-PAGE protein band pattern for thaumatin I and II - HPLC protein profile - Protein content by Kjeldahl or Dumas - Solubility and clarity of solution SDS-PAGE protein band pattern for thaumatin I and II is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC protein profile and SDS-PAGE identity reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Thaumatin the moisture limit is ≤10.0%. The particle size is ≥95% through 100 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Thaumatin can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Thaumatin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Thaumatin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Thaumatin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Thaumatin grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/thaumatin/grades/ Reviewed: 2026-11-20 Thaumatin is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Thaumatin is no exception: Thaumatin 95% powder and Thaumatin 98% can share an assay and still behave differently in the line. ## The grade map Thaumatin grades | | Grade | Best fit | What changes | Thaumatin 95% powder | Trace-level sweetness and mouthfeel | Standard food grade | Thaumatin 98% | High-purity applications | Lower carrier load, higher cost | Thaumatin liquid | Beverage lines | Preservation and cold-chain requirements | Thaumatin blend | Sweetener systems | Carrier and other actives must be declared ## Sweetness and taste The indicative sweetness is 2,000–3,000 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Slow onset, intense sweetness with a liquorice-like tail; at low dose it adds body and rounds other sweeteners. The use level is 0.0005–0.005% in food, depending on the category and the blend. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; solutions are protein systems and need a preservation and pH strategy. Hygroscopic; store sealed below 25 °C and protect from moisture and heat. ## The grade decision The level-four page for this product compares Powder with Liquid. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Thaumatin powder vs liquid: the protein decides the process Thaumatin is a protein, so heat, pH and microbial control matter more than they do for a glycoside powder. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Thaumatin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Thaumatin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Thaumatin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Thaumatin stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/thaumatin/stability/ Reviewed: 2026-11-20 Thaumatin is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C and protect from moisture and heat. The specification limits moisture to ≤10.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix The protein unfolds at high temperature; add after the heat step or validate the remaining activity in the finished product. Most stable at mildly acidic to neutral pH; extremes and prolonged heat reduce activity. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Thaumatin is added at 0.0005–0.005% in food, depending on the category and the blend. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; solutions are protein systems and need a preservation and pH strategy. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Thaumatin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Thaumatin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Thaumatin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Thaumatin: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/thaumatin/moq/ Reviewed: 2026-11-20 Thaumatin is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Thaumatin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Thaumatin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Thaumatin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Thaumatin is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/thaumatin/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Thaumatin can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Thaumatin needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - SDS-PAGE protein band pattern for thaumatin I and II - HPLC protein profile - Protein content by Kjeldahl or Dumas - Solubility and clarity of solution For this grade, the primary assay is HPLC protein profile and SDS-PAGE identity. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin or other protein used as a bulking agent without declaration - A lower-protein extract sold as 95% - Thaumatin blended with another high-intensity sweetener - Non-plant protein material presented as thaumatin None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Thaumatin, the relevant identity format is Protein ≥95%, thaumatin I/II by HPLC. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Thaumatin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Thaumatin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Thaumatin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Thaumatin powder vs liquid: the protein decides the process URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/thaumatin/grades/thaumatin-powder-vs-liquid/ Reviewed: 2026-11-20 A protein needs a different handling plan is a formulation question, not a catalogue question. Thaumatin is a protein, so heat, pH and microbial control matter more than they do for a glycoside powder. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThaumatin is a protein, so heat, pH and microbial control matter more than they do for a glycoside powder. ## The two options Thaumatin powder vs liquid: the protein decides the process | | Option | What it is | Option A | Powder: stable dry, easy to weigh, but dust and rehydration need care; add it after high-heat steps. | Option B | Liquid: easy to disperse, but water activity, preservation and cold-chain add cost and validation work. ## Taste and sweetness The published sweetness for Thaumatin is 2,000–3,000 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Slow onset, intense sweetness with a liquorice-like tail; at low dose it adds body and rounds other sweeteners. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Powder: stable dry, easy to weigh, but dust and rehydration need care; add it after high-heat steps. Liquid: easy to disperse, but water activity, preservation and cold-chain add cost and validation work. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; solutions are protein systems and need a preservation and pH strategy. The protein unfolds at high temperature; add after the heat step or validate the remaining activity in the finished product. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Thaumatin 95% powder, Thaumatin 98%, Thaumatin liquid, Thaumatin blend. The primary specification is ≥95.0% (dry basis). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; solutions are protein systems and need a preservation and pH strategy. 0.0005–0.005% in food, depending on the category and the blend is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use powder for dry blends and any process with a kill step, adding it after the heat where possible. Use liquid only when the line is set up for a preserved protein solution and the shelf life has been validated. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Thaumatin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Thaumatin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Thaumatin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Neohesperidin Dihydrochalcone (NHDC) 98%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/neohesperidin-dihydrochalcone/coa/ Reviewed: 2026-11-20 Neohesperidin Dihydrochalcone (NHDC) 98% (CAS 20702-77-6) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineNeohesperidin Dihydrochalcone (NHDC) 98% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection at 280 nm. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Neohesperidin Dihydrochalcone (NHDC) 98% | | Parameter | Specification | Neohesperidin dihydrochalcone | ≥98.0% (HPLC) | Neohesperidin | ≤1.0% (HPLC) | Appearance | White to off-white powder | Moisture | ≤5.0% | pH (1% solution) | 5.0–7.0 | Solubility | Slightly soluble in water; soluble in ethanol | Particle size | ≥95% through 80 mesh | Bulk density | 0.35–0.65 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Neohesperidin Dihydrochalcone (NHDC) 98% the identity evidence used for release is: - HPLC profile of NHDC ≥98%, neohesperidin ≤1% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference HPLC profile of NHDC ≥98%, neohesperidin ≤1% against reference standards is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection at 280 nm reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Neohesperidin Dihydrochalcone (NHDC) 98% the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Neohesperidin Dihydrochalcone (NHDC) 98% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Neohesperidin Dihydrochalcone (NHDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neohesperidin Dihydrochalcone (NHDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neohesperidin Dihydrochalcone (NHDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Neohesperidin Dihydrochalcone (NHDC) 98% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/neohesperidin-dihydrochalcone/grades/ Reviewed: 2026-11-20 Neohesperidin Dihydrochalcone (NHDC) 98% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Neohesperidin Dihydrochalcone (NHDC) 98% is no exception: NHDC 98% powder and NHDC 98% granular can share an assay and still behave differently in the line. ## The grade map Neohesperidin Dihydrochalcone (NHDC) 98% grades | | Grade | Best fit | What changes | NHDC 98% powder | Beverages and flavour systems | High intensity, low use rate | NHDC 98% granular | Dry blends and tabletop | Better flow, lower dust | NHDC liquid | Syrup and beverage lines | Solvent and active content must be declared | NHDC premix | Accurate micro-dosing | Carrier and homogeneity must be specified ## Sweetness and taste The indicative sweetness is 1,500–2,000 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Intense sweetness with a slow onset, a long lingering tail and a cooling, slightly menthol-like note at higher doses. The use level is 0.0003–0.005% in food, depending on the category and the blend. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. Moderately hygroscopic; store sealed below 25 °C. ## The grade decision The level-four page for this product compares NHDC 98% powder with NHDC 98% granular. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. NHDC vs NDC: two citrus dihydrochalcones, not one ingredient The two options are different specifications, not two names for the same drum. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Neohesperidin Dihydrochalcone (NHDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neohesperidin Dihydrochalcone (NHDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neohesperidin Dihydrochalcone (NHDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Neohesperidin Dihydrochalcone (NHDC) 98% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/neohesperidin-dihydrochalcone/stability/ Reviewed: 2026-11-20 Neohesperidin Dihydrochalcone (NHDC) 98% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderately hygroscopic; store sealed below 25 °C. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal food processing; taste should be rechecked after heat. Stable in mildly acidic to neutral systems; solubility is usually the limiting factor. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Neohesperidin Dihydrochalcone (NHDC) 98% is added at 0.0003–0.005% in food, depending on the category and the blend. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Neohesperidin Dihydrochalcone (NHDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neohesperidin Dihydrochalcone (NHDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neohesperidin Dihydrochalcone (NHDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Neohesperidin Dihydrochalcone (NHDC) 98%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/neohesperidin-dihydrochalcone/moq/ Reviewed: 2026-11-20 Neohesperidin Dihydrochalcone (NHDC) 98% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Neohesperidin Dihydrochalcone (NHDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neohesperidin Dihydrochalcone (NHDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neohesperidin Dihydrochalcone (NHDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Neohesperidin Dihydrochalcone (NHDC) 98% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/neohesperidin-dihydrochalcone/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Neohesperidin Dihydrochalcone (NHDC) 98% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Neohesperidin Dihydrochalcone (NHDC) 98% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC profile of NHDC ≥98%, neohesperidin ≤1% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference For this grade, the primary assay is HPLC with UV detection at 280 nm. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-purity extract sold as Neohesperidin Dihydrochalcone (NHDC) 98% - Maltodextrin, dextrose or another carrier not declared - A related botanical or glycoside presented as the named grade - Undeclared blending with a cheaper high-intensity sweetener None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Neohesperidin Dihydrochalcone (NHDC) 98%, the relevant identity format is NHDC ≥98%, neohesperidin ≤1%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Neohesperidin Dihydrochalcone (NHDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neohesperidin Dihydrochalcone (NHDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neohesperidin Dihydrochalcone (NHDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 NHDC vs NDC: two citrus dihydrochalcones, not one ingredient URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/neohesperidin-dihydrochalcone/grades/nhdc-vs-ndc/ Reviewed: 2026-11-20 The acronyms are not interchangeable is a formulation question, not a catalogue question. The two options are different specifications, not two names for the same drum. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe two options are different specifications, not two names for the same drum. ## The two options NHDC vs NDC: two citrus dihydrochalcones, not one ingredient | | Option | What it is | Option A | NHDC 98% powder: the standard catalog grade. | Option B | NHDC 98% granular: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Neohesperidin Dihydrochalcone (NHDC) 98% is 1,500–2,000 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Intense sweetness with a slow onset, a long lingering tail and a cooling, slightly menthol-like note at higher doses. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process NHDC 98% powder: the standard catalog grade. NHDC 98% granular: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. Stable in dry form and through normal food processing; taste should be rechecked after heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are NHDC 98% powder, NHDC 98% granular, NHDC liquid, NHDC premix. The primary specification is ≥98.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Slightly soluble in water; a co-solvent or a diluted pre-mix is usually needed in beverages. 0.0003–0.005% in food, depending on the category and the blend is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision If it calls for naringin DC, specify NDC and do not accept an NHDC certificate as a substitute. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Neohesperidin Dihydrochalcone (NHDC) 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neohesperidin Dihydrochalcone (NHDC) 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neohesperidin Dihydrochalcone (NHDC) 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Monoammonium Glycyrrhizinate 98%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monoammonium-glycyrrhizinate/coa/ Reviewed: 2026-11-20 Monoammonium Glycyrrhizinate 98% (CAS 53956-04-0) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineMonoammonium Glycyrrhizinate 98% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Monoammonium Glycyrrhizinate 98% | | Parameter | Specification | Monoammonium glycyrrhizinate | ≥98.0% (HPLC) | Glycyrrhizic acid | ≥65.0% (calculated) | Appearance | White to cream-coloured powder | Moisture | ≤6.0% | pH (1% solution) | 5.0–7.0 | Solubility | Soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.35–0.65 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Monoammonium Glycyrrhizinate 98% the identity evidence used for release is: - HPLC profile of Monoammonium glycyrrhizinate ≥98%, glycyrrhizic acid ≥65% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference HPLC profile of Monoammonium glycyrrhizinate ≥98%, glycyrrhizic acid ≥65% against reference standards is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Monoammonium Glycyrrhizinate 98% the moisture limit is ≤6.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Monoammonium Glycyrrhizinate 98% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Monoammonium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monoammonium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monoammonium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Monoammonium Glycyrrhizinate 98% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monoammonium-glycyrrhizinate/grades/ Reviewed: 2026-11-20 Monoammonium Glycyrrhizinate 98% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Monoammonium Glycyrrhizinate 98% is no exception: MAG 98% powder and MAG 65% extract can share an assay and still behave differently in the line. ## The grade map Monoammonium Glycyrrhizinate 98% grades | | Grade | Best fit | What changes | MAG 98% powder | Water-soluble flavour systems | Easier dissolution than the acid | MAG 65% extract | Cost-sensitive flavour use | Lower active load, more background | MAG granular | Dry blends | Better flow, lower dust ## Sweetness and taste The indicative sweetness is 50–100 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Liquorice sweetness with a slow onset and a long tail; the ammonium salt is easier to dissolve than the acid. The use level is 0.002–0.02% in food, depending on the category and the liquorice note. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; easier to formulate than the free acid in neutral systems. Moderately hygroscopic; store sealed and away from moisture. ## The grade decision The level-four page for this product compares Monoammonium glycyrrhizinate with Glycyrrhizin. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Monoammonium glycyrrhizinate vs glycyrrhizin: the salt changes the solution Glycyrrhizin is the free acid and is sparingly soluble; the monoammonium salt is water-soluble and easier in a clear beverage. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Monoammonium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monoammonium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monoammonium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Monoammonium Glycyrrhizinate 98% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monoammonium-glycyrrhizinate/stability/ Reviewed: 2026-11-20 Monoammonium Glycyrrhizinate 98% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderately hygroscopic; store sealed and away from moisture. The specification limits moisture to ≤6.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; hydrolysis to glycyrrhetinic acid should be checked in acidic solution. Soluble and stable at mildly acidic to neutral pH; very low pH requires a shelf-life check. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Monoammonium Glycyrrhizinate 98% is added at 0.002–0.02% in food, depending on the category and the liquorice note. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; easier to formulate than the free acid in neutral systems. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Monoammonium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monoammonium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monoammonium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Monoammonium Glycyrrhizinate 98%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monoammonium-glycyrrhizinate/moq/ Reviewed: 2026-11-20 Monoammonium Glycyrrhizinate 98% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Monoammonium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monoammonium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monoammonium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Monoammonium Glycyrrhizinate 98% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monoammonium-glycyrrhizinate/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Monoammonium Glycyrrhizinate 98% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Monoammonium Glycyrrhizinate 98% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC profile of Monoammonium glycyrrhizinate ≥98%, glycyrrhizic acid ≥65% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-purity extract sold as Monoammonium Glycyrrhizinate 98% - Maltodextrin, dextrose or another carrier not declared - A related botanical or glycoside presented as the named grade - Undeclared blending with a cheaper high-intensity sweetener None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Monoammonium Glycyrrhizinate 98%, the relevant identity format is Monoammonium glycyrrhizinate ≥98%, glycyrrhizic acid ≥65%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Monoammonium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monoammonium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monoammonium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Monoammonium glycyrrhizinate vs glycyrrhizin: the salt changes the solution URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monoammonium-glycyrrhizinate/grades/mag-vs-glycyrrhizin/ Reviewed: 2026-11-20 Same active family, different solubility is a formulation question, not a catalogue question. Glycyrrhizin is the free acid and is sparingly soluble; the monoammonium salt is water-soluble and easier in a clear beverage. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineGlycyrrhizin is the free acid and is sparingly soluble; the monoammonium salt is water-soluble and easier in a clear beverage. ## The two options Monoammonium glycyrrhizinate vs glycyrrhizin: the salt changes the solution | | Option | What it is | Option A | Monoammonium glycyrrhizinate: water-soluble, a different salt name and a different molecular weight. | Option B | Glycyrrhizin: the free acid, higher active per kilogram, but sparingly soluble without alkaline conditions or a co-solvent. ## Taste and sweetness The published sweetness for Monoammonium Glycyrrhizinate 98% is 50–100 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Liquorice sweetness with a slow onset and a long tail; the ammonium salt is easier to dissolve than the acid. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Monoammonium glycyrrhizinate: water-soluble, a different salt name and a different molecular weight. Glycyrrhizin: the free acid, higher active per kilogram, but sparingly soluble without alkaline conditions or a co-solvent. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; easier to formulate than the free acid in neutral systems. Stable in dry form; hydrolysis to glycyrrhetinic acid should be checked in acidic solution. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are MAG 98% powder, MAG 65% extract, MAG granular. The primary specification is ≥98.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; easier to formulate than the free acid in neutral systems. 0.002–0.02% in food, depending on the category and the liquorice note is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the free acid for a dry blend or an alkaline system where the active load matters. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Monoammonium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monoammonium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monoammonium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Dipotassium Glycyrrhizinate 98%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/dipotassium-glycyrrhizinate/coa/ Reviewed: 2026-11-20 Dipotassium Glycyrrhizinate 98% (CAS 68797-35-3) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineDipotassium Glycyrrhizinate 98% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Dipotassium Glycyrrhizinate 98% | | Parameter | Specification | Dipotassium glycyrrhizinate | ≥98.0% (HPLC) | Glycyrrhizic acid | ≥65.0% (calculated) | Appearance | White to cream-coloured powder | Moisture | ≤6.0% | pH (1% solution) | 6.0–8.0 | Solubility | Soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.35–0.65 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Dipotassium Glycyrrhizinate 98% the identity evidence used for release is: - HPLC profile of Dipotassium glycyrrhizinate ≥98%, glycyrrhizic acid ≥65% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference HPLC profile of Dipotassium glycyrrhizinate ≥98%, glycyrrhizic acid ≥65% against reference standards is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Dipotassium Glycyrrhizinate 98% the moisture limit is ≤6.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Dipotassium Glycyrrhizinate 98% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Dipotassium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Dipotassium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Dipotassium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Dipotassium Glycyrrhizinate 98% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/dipotassium-glycyrrhizinate/grades/ Reviewed: 2026-11-20 Dipotassium Glycyrrhizinate 98% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Dipotassium Glycyrrhizinate 98% is no exception: DPG 98% powder and DPG 65% extract can share an assay and still behave differently in the line. ## The grade map Dipotassium Glycyrrhizinate 98% grades | | Grade | Best fit | What changes | DPG 98% powder | Water-soluble flavour systems | Potassium salt, neutral solution | DPG 65% extract | Cost-sensitive flavour use | Lower active load | DPG granular | Dry blends | Better flow ## Sweetness and taste The indicative sweetness is 50–100 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Liquorice sweetness with a long tail; the potassium salt is useful where a sodium or ammonium salt is not wanted. The use level is 0.002–0.02% in food or oral-care systems, depending on the liquorice note. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; a neutral-to-mildly-alkaline solution. Moderately hygroscopic; store sealed. ## The grade decision The level-four page for this product compares DPG 98% powder with DPG 65% extract. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Which Dipotassium Glycyrrhizinate 98% grade fits the brief? The two options are different specifications, not two names for the same drum. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Dipotassium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Dipotassium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Dipotassium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Dipotassium Glycyrrhizinate 98% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/dipotassium-glycyrrhizinate/stability/ Reviewed: 2026-11-20 Dipotassium Glycyrrhizinate 98% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderately hygroscopic; store sealed. The specification limits moisture to ≤6.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; hydrolysis should be checked in acidic solution. Soluble and stable at mildly acidic to mildly alkaline pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Dipotassium Glycyrrhizinate 98% is added at 0.002–0.02% in food or oral-care systems, depending on the liquorice note. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; a neutral-to-mildly-alkaline solution. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Dipotassium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Dipotassium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Dipotassium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Dipotassium Glycyrrhizinate 98%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/dipotassium-glycyrrhizinate/moq/ Reviewed: 2026-11-20 Dipotassium Glycyrrhizinate 98% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Dipotassium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Dipotassium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Dipotassium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Dipotassium Glycyrrhizinate 98% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/dipotassium-glycyrrhizinate/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Dipotassium Glycyrrhizinate 98% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Dipotassium Glycyrrhizinate 98% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC profile of Dipotassium glycyrrhizinate ≥98%, glycyrrhizic acid ≥65% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-purity extract sold as Dipotassium Glycyrrhizinate 98% - Maltodextrin, dextrose or another carrier not declared - A related botanical or glycoside presented as the named grade - Undeclared blending with a cheaper high-intensity sweetener None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Dipotassium Glycyrrhizinate 98%, the relevant identity format is Dipotassium glycyrrhizinate ≥98%, glycyrrhizic acid ≥65%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Dipotassium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Dipotassium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Dipotassium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Which Dipotassium Glycyrrhizinate 98% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/dipotassium-glycyrrhizinate/grades/dpg-vs-mag/ Reviewed: 2026-11-20 Same active family, different salts is a formulation question, not a catalogue question. The two options are different specifications, not two names for the same drum. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe two options are different specifications, not two names for the same drum. ## The two options Which Dipotassium Glycyrrhizinate 98% grade fits the brief? | | Option | What it is | Option A | DPG 98% powder: the standard catalog grade. | Option B | DPG 65% extract: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Dipotassium Glycyrrhizinate 98% is 50–100 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Liquorice sweetness with a long tail; the potassium salt is useful where a sodium or ammonium salt is not wanted. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process DPG 98% powder: the standard catalog grade. DPG 65% extract: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; a neutral-to-mildly-alkaline solution. Stable in dry form; hydrolysis should be checked in acidic solution. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are DPG 98% powder, DPG 65% extract, DPG granular. The primary specification is ≥98.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; a neutral-to-mildly-alkaline solution. 0.002–0.02% in food or oral-care systems, depending on the liquorice note is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the application and the process, then confirm the particle size, carrier and use level in a matrix trial. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Dipotassium Glycyrrhizinate 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Dipotassium Glycyrrhizinate 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Dipotassium Glycyrrhizinate 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Rubusoside 70%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rubusoside/coa/ Reviewed: 2026-11-20 Rubusoside 70% (CAS 64849-39-4) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineRubusoside 70% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Rubusoside 70% | | Parameter | Specification | Rubusoside | ≥70.0% (HPLC) | Total sweet glycosides | ≥80.0% (HPLC) | Appearance | White to off-white powder | Moisture | ≤5.0% | pH (1% solution) | 4.5–7.0 | Solubility | Soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.35–0.65 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Rubusoside 70% the identity evidence used for release is: - HPLC profile of Rubusoside ≥70%, total sweet glycosides ≥80% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference HPLC profile of Rubusoside ≥70%, total sweet glycosides ≥80% against reference standards is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Rubusoside 70% the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Rubusoside 70% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Rubusoside 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rubusoside 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rubusoside 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Rubusoside 70% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rubusoside/grades/ Reviewed: 2026-11-20 Rubusoside 70% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Rubusoside 70% is no exception: Rubusoside 70% and Rubusoside 90% can share an assay and still behave differently in the line. ## The grade map Rubusoside 70% grades | | Grade | Best fit | What changes | Rubusoside 70% | Beverage and tabletop | Standard sweet-tea extract | Rubusoside 90% | Premium clean-taste use | Higher purity, higher cost | Rubusoside liquid | Syrup lines | Carrier and solids must be declared ## Sweetness and taste The indicative sweetness is 100–200 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Sweet with a slower onset and a clean finish; a slight herbal note at higher doses. The use level is 0.01–0.05% in beverages, depending on the target sucrose equivalence. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; clear at typical use levels. Hygroscopic; store sealed below 25 °C. ## The grade decision The level-four page for this product compares Rubusoside with Rubusoside 90%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Rubusoside vs steviol glycosides: two natural high-intensity routes Rubusoside comes from sweet tea, not stevia. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Rubusoside 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rubusoside 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rubusoside 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Rubusoside 70% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rubusoside/stability/ Reviewed: 2026-11-20 Rubusoside 70% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; validate the taste after pasteurisation. Stable across normal beverage pH; low pH and heat should be tested. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Rubusoside 70% is added at 0.01–0.05% in beverages, depending on the target sucrose equivalence. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; clear at typical use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Rubusoside 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rubusoside 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rubusoside 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Rubusoside 70%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rubusoside/moq/ Reviewed: 2026-11-20 Rubusoside 70% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Rubusoside 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rubusoside 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rubusoside 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Rubusoside 70% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rubusoside/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Rubusoside 70% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Rubusoside 70% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC profile of Rubusoside ≥70%, total sweet glycosides ≥80% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-purity extract sold as Rubusoside 70% - Maltodextrin, dextrose or another carrier not declared - A related botanical or glycoside presented as the named grade - Undeclared blending with a cheaper high-intensity sweetener None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Rubusoside 70%, the relevant identity format is Rubusoside ≥70%, total sweet glycosides ≥80%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Rubusoside 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rubusoside 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rubusoside 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Rubusoside vs steviol glycosides: two natural high-intensity routes URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/rubusoside/grades/rubusoside-vs-stevia/ Reviewed: 2026-11-20 Different plants, different curves is a formulation question, not a catalogue question. Rubusoside comes from sweet tea, not stevia. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineRubusoside comes from sweet tea, not stevia. ## The two options Rubusoside vs steviol glycosides: two natural high-intensity routes | | Option | What it is | Option A | Rubusoside: sweet-tea glycoside, 100–200×, a different taste and a different supply chain. | Option B | Rubusoside 90%: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Rubusoside 70% is 100–200 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Sweet with a slower onset and a clean finish; a slight herbal note at higher doses. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Rubusoside: sweet-tea glycoside, 100–200×, a different taste and a different supply chain. Rubusoside 90%: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; clear at typical use levels. Stable in dry form; validate the taste after pasteurisation. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Rubusoside 70%, Rubusoside 90%, Rubusoside liquid. The primary specification is ≥70.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; clear at typical use levels. 0.01–0.05% in beverages, depending on the target sucrose equivalence is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the application and the process, then confirm the particle size, carrier and use level in a matrix trial. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Rubusoside 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Rubusoside 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Rubusoside 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Glucosylated Steviol Glycosides 90%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glucosylated-steviol-glycosides/coa/ Reviewed: 2026-11-20 Glucosylated Steviol Glycosides 90% (CAS —) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineGlucosylated Steviol Glycosides 90% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Glucosylated Steviol Glycosides 90% | | Parameter | Specification | Total steviol glycosides | ≥90.0% (HPLC) | Glucosylated glycosides | ≥60.0% (HPLC) | Appearance | White to off-white powder | Moisture | ≤5.0% | pH (1% solution) | 4.5–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.35–0.65 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Glucosylated Steviol Glycosides 90% the identity evidence used for release is: - HPLC profile of Total steviol glycosides ≥90%, glucosylated fraction ≥60% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference HPLC profile of Total steviol glycosides ≥90%, glucosylated fraction ≥60% against reference standards is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Glucosylated Steviol Glycosides 90% the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Glucosylated Steviol Glycosides 90% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Glucosylated Steviol Glycosides 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glucosylated Steviol Glycosides 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glucosylated Steviol Glycosides 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Glucosylated Steviol Glycosides 90% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glucosylated-steviol-glycosides/grades/ Reviewed: 2026-11-20 Glucosylated Steviol Glycosides 90% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Glucosylated Steviol Glycosides 90% is no exception: GSG 90% powder and GSG 80% powder can share an assay and still behave differently in the line. ## The grade map Glucosylated Steviol Glycosides 90% grades | | Grade | Best fit | What changes | GSG 90% powder | Beverages and tabletop | Improved solubility | GSG 80% powder | Cost-sensitive food use | Lower active load | GSG liquid | Syrup lines | Carrier and solids must be declared ## Sweetness and taste The indicative sweetness is 100–200 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Sweet with a rounded onset and less linger than Reb A; the glucosylation changes the mouthfeel. The use level is 0.01–0.06% in beverages, depending on the target sucrose equivalence. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; improved solubility versus high-purity Reb A. Hygroscopic; store sealed below 25 °C. ## The grade decision The level-four page for this product compares GSG 90% powder with GSG 80% powder. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Which Glucosylated Steviol Glycosides 90% grade fits the brief? It is not simply a better Reb A. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Glucosylated Steviol Glycosides 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glucosylated Steviol Glycosides 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glucosylated Steviol Glycosides 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Glucosylated Steviol Glycosides 90% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glucosylated-steviol-glycosides/stability/ Reviewed: 2026-11-20 Glucosylated Steviol Glycosides 90% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; validate the taste and the assay after the heat step. Stable across normal beverage pH; low pH should be tested. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Glucosylated Steviol Glycosides 90% is added at 0.01–0.06% in beverages, depending on the target sucrose equivalence. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; improved solubility versus high-purity Reb A. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Glucosylated Steviol Glycosides 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glucosylated Steviol Glycosides 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glucosylated Steviol Glycosides 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Glucosylated Steviol Glycosides 90%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glucosylated-steviol-glycosides/moq/ Reviewed: 2026-11-20 Glucosylated Steviol Glycosides 90% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Glucosylated Steviol Glycosides 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glucosylated Steviol Glycosides 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glucosylated Steviol Glycosides 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Glucosylated Steviol Glycosides 90% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glucosylated-steviol-glycosides/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Glucosylated Steviol Glycosides 90% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Glucosylated Steviol Glycosides 90% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC profile of Total steviol glycosides ≥90%, glucosylated fraction ≥60% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-purity extract sold as Glucosylated Steviol Glycosides 90% - Maltodextrin, dextrose or another carrier not declared - A related botanical or glycoside presented as the named grade - Undeclared blending with a cheaper high-intensity sweetener None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Glucosylated Steviol Glycosides 90%, the relevant identity format is Total steviol glycosides ≥90%, glucosylated fraction ≥60%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Glucosylated Steviol Glycosides 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glucosylated Steviol Glycosides 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glucosylated Steviol Glycosides 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Which Glucosylated Steviol Glycosides 90% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/glucosylated-steviol-glycosides/grades/gsg-vs-reb-a/ Reviewed: 2026-11-20 A different steviol route is a formulation question, not a catalogue question. It is not simply a better Reb A. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineIt is not simply a better Reb A. ## The two options Which Glucosylated Steviol Glycosides 90% grade fits the brief? | | Option | What it is | Option A | GSG 90% powder: the standard catalog grade. | Option B | GSG 80% powder: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Glucosylated Steviol Glycosides 90% is 100–200 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Sweet with a rounded onset and less linger than Reb A; the glucosylation changes the mouthfeel. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process GSG 90% powder: the standard catalog grade. GSG 80% powder: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; improved solubility versus high-purity Reb A. Stable in dry form; validate the taste and the assay after the heat step. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are GSG 90% powder, GSG 80% powder, GSG liquid. The primary specification is ≥90.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; improved solubility versus high-purity Reb A. 0.01–0.06% in beverages, depending on the target sucrose equivalence is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose GSG when solubility or the Reb A tail is the technical problem and the market accepts the grade. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Glucosylated Steviol Glycosides 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Glucosylated Steviol Glycosides 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Glucosylated Steviol Glycosides 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Brazzein 90%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/brazzein/coa/ Reviewed: 2026-11-20 Brazzein 90% (CAS —) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineBrazzein 90% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC protein profile and SDS-PAGE. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Brazzein 90% | | Parameter | Specification | Brazzein protein | ≥90.0% (protein basis) | Appearance | White to off-white powder | Moisture | ≤8.0% | pH (1% solution) | 4.5–7.0 | Solubility | Soluble in water | Particle size | ≥95% through 100 mesh | Bulk density | 0.25–0.55 g/mL | Ash | ≤3.0% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Brazzein 90% the identity evidence used for release is: - HPLC profile of Brazzein protein ≥90%, SDS-PAGE identity against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference HPLC profile of Brazzein protein ≥90%, SDS-PAGE identity against reference standards is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC protein profile and SDS-PAGE reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Brazzein 90% the moisture limit is ≤8.0%. The particle size is ≥95% through 100 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Brazzein 90% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Brazzein 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Brazzein 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Brazzein 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Brazzein 90% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/brazzein/grades/ Reviewed: 2026-11-20 Brazzein 90% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Brazzein 90% is no exception: Brazzein 90% and Brazzein 10% can share an assay and still behave differently in the line. ## The grade map Brazzein 90% grades | | Grade | Best fit | What changes | Brazzein 90% | Premium clean-label sweetness | High protein purity | Brazzein 10% | Cost-sensitive trials | Carrier and active content must be declared | Brazzein liquid | Beverage lines | Preservation and cold chain ## Sweetness and taste The indicative sweetness is 1,000–2,000 × sucrose, indicative for the 90% protein. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, fast-onset sweetness with a long tail; at high dose a slight protein note can appear. The use level is 0.0005–0.005% in food, depending on the category and the blend. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; a protein solution needs a pH and preservation strategy. Hygroscopic; store sealed below 25 °C and protect from heat. ## The grade decision The level-four page for this product compares Brazzein 90% with Brazzein 10%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Brazzein 90% vs a 10% premix: protein purity is not the only cost A 90% brazzein powder and a 10% premix can both be called brazzein; the active content, the allergen file and the use level are different. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Brazzein 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Brazzein 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Brazzein 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Brazzein 90% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/brazzein/stability/ Reviewed: 2026-11-20 Brazzein 90% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C and protect from heat. The specification limits moisture to ≤8.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix A protein: high heat can unfold it. Add after the heat step or validate the activity that survives. Most stable at mildly acidic to neutral pH; extremes reduce activity. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Brazzein 90% is added at 0.0005–0.005% in food, depending on the category and the blend. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; a protein solution needs a pH and preservation strategy. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Brazzein 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Brazzein 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Brazzein 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Brazzein 90%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/brazzein/moq/ Reviewed: 2026-11-20 Brazzein 90% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Brazzein 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Brazzein 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Brazzein 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Brazzein 90% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/brazzein/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Brazzein 90% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Brazzein 90% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC profile of Brazzein protein ≥90%, SDS-PAGE identity against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference For this grade, the primary assay is HPLC protein profile and SDS-PAGE. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-purity extract sold as Brazzein 90% - Maltodextrin, dextrose or another carrier not declared - A related botanical or glycoside presented as the named grade - Undeclared blending with a cheaper high-intensity sweetener None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Brazzein 90%, the relevant identity format is Brazzein protein ≥90%, SDS-PAGE identity. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Brazzein 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Brazzein 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Brazzein 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Brazzein 90% vs a 10% premix: protein purity is not the only cost URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/brazzein/grades/brazzein-purity-vs-carrier/ Reviewed: 2026-11-20 The carrier decides the dose is a formulation question, not a catalogue question. A 90% brazzein powder and a 10% premix can both be called brazzein; the active content, the allergen file and the use level are different. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 90% brazzein powder and a 10% premix can both be called brazzein; the active content, the allergen file and the use level are different. ## The two options Brazzein 90% vs a 10% premix: protein purity is not the only cost | | Option | What it is | Option A | Brazzein 90%: higher active per kilogram, more demanding handling, higher cost per kilogram. | Option B | Brazzein 10%: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Brazzein 90% is 1,000–2,000 × sucrose, indicative for the 90% protein. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, fast-onset sweetness with a long tail; at high dose a slight protein note can appear. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Brazzein 90%: higher active per kilogram, more demanding handling, higher cost per kilogram. Brazzein 10%: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; a protein solution needs a pH and preservation strategy. A protein: high heat can unfold it. Add after the heat step or validate the activity that survives. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Brazzein 90%, Brazzein 10%, Brazzein liquid. The primary specification is ≥90.0% (protein basis). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; a protein solution needs a pH and preservation strategy. 0.0005–0.005% in food, depending on the category and the blend is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the batch size and the smallest accurate weighment. A high-purity protein is not useful if the line cannot weigh it reproducibly; a premix is not cheaper if the carrier load changes the taste. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Brazzein 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Brazzein 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Brazzein 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Monellin 90%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monellin/coa/ Reviewed: 2026-11-20 Monellin 90% (CAS —) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineMonellin 90% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC protein profile and SDS-PAGE. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Monellin 90% | | Parameter | Specification | Monellin protein | ≥90.0% (protein basis) | Appearance | White to off-white powder | Moisture | ≤8.0% | pH (1% solution) | 4.5–7.0 | Solubility | Soluble in water | Particle size | ≥95% through 100 mesh | Bulk density | 0.25–0.55 g/mL | Ash | ≤3.0% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Monellin 90% the identity evidence used for release is: - HPLC profile of Monellin protein ≥90%, SDS-PAGE identity against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference HPLC profile of Monellin protein ≥90%, SDS-PAGE identity against reference standards is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC protein profile and SDS-PAGE reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Monellin 90% the moisture limit is ≤8.0%. The particle size is ≥95% through 100 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Monellin 90% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Monellin 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monellin 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monellin 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Monellin 90% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monellin/grades/ Reviewed: 2026-11-20 Monellin 90% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Monellin 90% is no exception: Monellin 90% and Monellin 10% can share an assay and still behave differently in the line. ## The grade map Monellin 90% grades | | Grade | Best fit | What changes | Monellin 90% | Premium clean-label sweetness | High protein purity | Monellin 10% | Cost-sensitive trials | Carrier and active content must be declared | Monellin liquid | Beverage lines | Preservation and cold chain ## Sweetness and taste The indicative sweetness is 2,000–3,000 × sucrose, indicative for the 90% protein. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Intense sweetness with a slow onset and a long tail; the protein can add body. The use level is 0.0003–0.003% in food, depending on the category and the blend. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; a protein solution needs a pH and preservation strategy. Hygroscopic; store sealed below 25 °C and protect from heat. ## The grade decision The level-four page for this product compares High protein purity. with Monellin 10%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Monellin 90%: Monellin 90% vs Monellin 10% The grade is decided by the application and the process. The two options can share an assay and still behave differently in the line. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Monellin 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monellin 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monellin 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Monellin 90% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monellin/stability/ Reviewed: 2026-11-20 Monellin 90% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C and protect from heat. The specification limits moisture to ≤8.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix A protein: high heat can unfold it. Add after the heat step or validate the remaining activity. Most stable at mildly acidic to neutral pH; extremes reduce activity. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Monellin 90% is added at 0.0003–0.003% in food, depending on the category and the blend. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; a protein solution needs a pH and preservation strategy. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Monellin 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monellin 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monellin 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Monellin 90%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monellin/moq/ Reviewed: 2026-11-20 Monellin 90% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Monellin 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monellin 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monellin 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Monellin 90% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monellin/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Monellin 90% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Monellin 90% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC profile of Monellin protein ≥90%, SDS-PAGE identity against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference For this grade, the primary assay is HPLC protein profile and SDS-PAGE. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-purity extract sold as Monellin 90% - Maltodextrin, dextrose or another carrier not declared - A related botanical or glycoside presented as the named grade - Undeclared blending with a cheaper high-intensity sweetener None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Monellin 90%, the relevant identity format is Monellin protein ≥90%, SDS-PAGE identity. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Monellin 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monellin 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monellin 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Monellin 90%: Monellin 90% vs Monellin 10% URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monellin/grades/monellin-grade-decision/ Reviewed: 2026-11-20 Two grades, one application decision is a formulation question, not a catalogue question. The grade is decided by the application and the process. The two options can share an assay and still behave differently in the line. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe grade is decided by the application and the process. The two options can share an assay and still behave differently in the line. ## The two options Monellin 90%: Monellin 90% vs Monellin 10% | | Option | What it is | Option A | High protein purity. | Option B | Monellin 10%: Cost-sensitive trials. Carrier and active content must be declared. ## Taste and sweetness The published sweetness for Monellin 90% is 2,000–3,000 × sucrose, indicative for the 90% protein. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Intense sweetness with a slow onset and a long tail; the protein can add body. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process High protein purity. Monellin 10%: Cost-sensitive trials. Carrier and active content must be declared. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; a protein solution needs a pH and preservation strategy. A protein: high heat can unfold it. Add after the heat step or validate the remaining activity. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Monellin 90%, Monellin 10%, Monellin liquid. The primary specification is ≥90.0% (protein basis). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; a protein solution needs a pH and preservation strategy. 0.0003–0.003% in food, depending on the category and the blend is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the application and the process, then confirm the particle size, carrier and use level in a matrix trial. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Monellin 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monellin 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monellin 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Monk Fruit Powder 10%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-powder/coa/ Reviewed: 2026-11-20 Monk Fruit Powder 10% (CAS —) is a plant-derived high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineMonk Fruit Powder 10% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV or ELSD detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Monk Fruit Powder 10% | | Parameter | Specification | Total mogrosides | ≥10.0% (HPLC) | Mogroside V | ≥6.0% (HPLC) | Appearance | Light yellow to light brown powder | Moisture | ≤5.0% | pH (1% solution) | 4.0–7.0 | Solubility | Soluble or dispersible in water; some fruit solids may haze | Particle size | ≥95% through 80 mesh | Bulk density | 0.35–0.65 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Monk Fruit Powder 10% the identity evidence used for release is: - HPLC profile of Total mogrosides ≥10%, Mogroside V ≥6% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference HPLC profile of Total mogrosides ≥10%, Mogroside V ≥6% against reference standards is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV or ELSD detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Monk Fruit Powder 10% the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Monk Fruit Powder 10% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Monk Fruit Powder 10% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Powder 10%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Powder 10%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Monk Fruit Powder 10% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-powder/grades/ Reviewed: 2026-11-20 Monk Fruit Powder 10% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Monk Fruit Powder 10% is no exception: Monk fruit powder 10% and Monk fruit powder 20% can share an assay and still behave differently in the line. ## The grade map Monk Fruit Powder 10% grades | | Grade | Best fit | What changes | Monk fruit powder 10% | Body and mild sweetness | More colour and fruit solids | Monk fruit powder 20% | Higher sweetness | Lower use rate, higher cost | Organic monk fruit powder | Organic-certified products | Certificate and traceability required ## Sweetness and taste The indicative sweetness is 10–20 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild, fruit-forward sweetness with a melon note; more colour and body than the high-purity extract. The use level is 0.05–0.5% in beverages and foods, depending on the sweetness and body target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble or dispersible in water; fruit solids can haze a clear beverage. Hygroscopic; store sealed below 25 °C and 60% RH. ## The grade decision The level-four page for this product compares Monk fruit powder 10% with Monk fruit extract 50%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Which Monk Fruit Powder 10% grade fits the brief? A 10% fruit powder and a 50% Mogroside V extract are not interchangeable. The powder brings colour and body; the extract brings a high-intensity dose. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Monk Fruit Powder 10% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Powder 10%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Powder 10%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Monk Fruit Powder 10% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-powder/stability/ Reviewed: 2026-11-20 Monk Fruit Powder 10% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C and 60% RH. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; colour and taste should be tested after heat. Stable across normal food pH; colour can shift in acidic beverages. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Monk Fruit Powder 10% is added at 0.05–0.5% in beverages and foods, depending on the sweetness and body target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble or dispersible in water; fruit solids can haze a clear beverage. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Monk Fruit Powder 10% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Powder 10%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Powder 10%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Monk Fruit Powder 10%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-powder/moq/ Reviewed: 2026-11-20 Monk Fruit Powder 10% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Monk Fruit Powder 10% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Powder 10%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Powder 10%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Monk Fruit Powder 10% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-powder/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Monk Fruit Powder 10% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Monk Fruit Powder 10% needs both. ## Why identity is a separate test The active is a glycoside, a mogroside or a protein, so the assay has to name the exact molecule or molecule family and the chromatographic method that separates it from its neighbours. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC profile of Total mogrosides ≥10%, Mogroside V ≥6% against reference standards - Secondary confirmation by UV or IR spectrum - Carrier and other-glycoside screen by the same method - Appearance and solution clarity against the reference For this grade, the primary assay is HPLC with UV or ELSD detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-purity extract sold as Monk Fruit Powder 10% - Maltodextrin, dextrose or another carrier not declared - A related botanical or glycoside presented as the named grade - Undeclared blending with a cheaper high-intensity sweetener None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Monk Fruit Powder 10%, the relevant identity format is Total mogrosides ≥10%, Mogroside V ≥6%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Monk Fruit Powder 10% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Powder 10%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Powder 10%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Which Monk Fruit Powder 10% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/natural-high-intensity/monk-fruit-powder/grades/monk-fruit-powder-vs-extract/ Reviewed: 2026-11-20 Two grades, two jobs is a formulation question, not a catalogue question. A 10% fruit powder and a 50% Mogroside V extract are not interchangeable. The powder brings colour and body; the extract brings a high-intensity dose. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 10% fruit powder and a 50% Mogroside V extract are not interchangeable. The powder brings colour and body; the extract brings a high-intensity dose. ## The two options Which Monk Fruit Powder 10% grade fits the brief? | | Option | What it is | Option A | Monk fruit powder 10%: mild sweetness, fruit solids, colour and body; a higher use rate. | Option B | Monk fruit extract 50%: high-intensity sweetness, lower use rate, less colour and carrier. ## Taste and sweetness The published sweetness for Monk Fruit Powder 10% is 10–20 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild, fruit-forward sweetness with a melon note; more colour and body than the high-purity extract. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Monk fruit powder 10%: mild sweetness, fruit solids, colour and body; a higher use rate. Monk fruit extract 50%: high-intensity sweetness, lower use rate, less colour and carrier. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble or dispersible in water; fruit solids can haze a clear beverage. Stable in dry form; colour and taste should be tested after heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Monk fruit powder 10%, Monk fruit powder 20%, Organic monk fruit powder. The primary specification is ≥10.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble or dispersible in water; fruit solids can haze a clear beverage. 0.05–0.5% in beverages and foods, depending on the sweetness and body target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use the powder when the product can carry colour and fruit solids and needs body. Use the 50% extract for a clear beverage or a high-intensity sweetening job. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Monk Fruit Powder 10% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit Powder 10%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit Powder 10%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Sucralose: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sucralose/coa/ Reviewed: 2026-11-20 Sucralose (CAS 56038-13-2) is a high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineSucralose is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with refractive index or UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Sucralose | | Parameter | Specification | Assay (dried basis) | 98.0–102.0% (HPLC) | Related substances | ≤2.0% (HPLC) | Appearance | White to off-white crystalline powder | Moisture | ≤1.0% | pH (10% solution) | 5.0–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh; micronized on request | Bulk density | 0.50–0.80 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Sucralose the identity evidence used for release is: - HPLC retention time against a sucralose reference standard - Related-substance profile by the same method - IR spectrum and optical rotation - Chloride and hydrolysis products where relevant HPLC retention time against a sucralose reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with refractive index or UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Sucralose the moisture limit is ≤1.0%. The particle size is ≥95% through 80 mesh; micronized on request. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Sucralose can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Sucralose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Sucralose grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sucralose/grades/ Reviewed: 2026-11-20 Sucralose is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Sucralose is no exception: Sucralose 99% powder and Micronized sucralose can share an assay and still behave differently in the line. ## The grade map Sucralose grades | | Grade | Best fit | What changes | Sucralose 99% powder | Beverages, dairy, tabletop | Standard grade | Micronized sucralose | Dry mixes and suspensions | Finer particle, faster dispersion | Granular sucralose | Tabletop and sachets | Better flow, lower dust | Liquid sucralose | Syrup and beverage lines | Active content and preservation must be specified ## Sweetness and taste The indicative sweetness is 400–600 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, sucrose-like onset with a slight lingering sweetness; the tail is shorter than saccharin but longer than aspartame. The use level is 0.005–0.05% in beverages, depending on the target sucrose equivalence. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; clear solutions at use levels. Low hygroscopicity; store sealed and dry. ## The grade decision The level-four page for this product compares Powder with Liquid. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Sucralose powder vs liquid: choosing the form for the line A 25% liquid sucralose is not a cheaper powder. It is a solution with water, a preservative challenge and a different dosing system. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Sucralose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Sucralose stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sucralose/stability/ Reviewed: 2026-11-20 Sucralose is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low hygroscopicity; store sealed and dry. The specification limits moisture to ≤1.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through typical beverage pasteurisation; avoid prolonged high-temperature hold at low pH. Stable across pH 3–7; hydrolysis increases at very low pH and high temperature. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Sucralose is added at 0.005–0.05% in beverages, depending on the target sucrose equivalence. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; clear solutions at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Sucralose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Sucralose: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sucralose/moq/ Reviewed: 2026-11-20 Sucralose is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Sucralose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Sucralose is what the specification says URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sucralose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Sucralose can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Sucralose needs both. ## Why identity is a separate test The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC retention time against a sucralose reference standard - Related-substance profile by the same method - IR spectrum and optical rotation - Chloride and hydrolysis products where relevant For this grade, the primary assay is HPLC with refractive index or UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin or dextrose bulking not declared - A lower-purity sucralose sold as 99% - Sucralose blended with another high-intensity sweetener - Liquid sucralose with undeclared preservative or carrier None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Sucralose, the relevant identity format is Sucralose 98.0–102.0%, related substances ≤2.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Sucralose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Sucralose powder vs liquid: choosing the form for the line URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sucralose/grades/sucralose-powder-vs-liquid/ Reviewed: 2026-11-20 The molecule is the same; the handling is not is a formulation question, not a catalogue question. A 25% liquid sucralose is not a cheaper powder. It is a solution with water, a preservative challenge and a different dosing system. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 25% liquid sucralose is not a cheaper powder. It is a solution with water, a preservative challenge and a different dosing system. ## The two options Sucralose powder vs liquid: choosing the form for the line | | Option | What it is | Option A | Powder: 98–102% active, easy to store, no water activity penalty, but dust and dissolution time. | Option B | Liquid: fast dispersion, no dust, lower active content, preservation and cold-chain requirements. ## Taste and sweetness The published sweetness for Sucralose is 400–600 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, sucrose-like onset with a slight lingering sweetness; the tail is shorter than saccharin but longer than aspartame. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Powder: 98–102% active, easy to store, no water activity penalty, but dust and dissolution time. Liquid: fast dispersion, no dust, lower active content, preservation and cold-chain requirements. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; clear solutions at use levels. Stable in dry form and through typical beverage pasteurisation; avoid prolonged high-temperature hold at low pH. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Sucralose 99% powder, Micronized sucralose, Granular sucralose, Liquid sucralose. The primary specification is 98.0–102.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; clear solutions at use levels. 0.005–0.05% in beverages, depending on the target sucrose equivalence is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose powder for dry blends and processes where water control matters. Choose liquid when the line already doses liquid sweeteners, the preservative system is validated and the lower active content is built into the batch sheet. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Sucralose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Acesulfame Potassium: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/acesulfame-potassium/coa/ Reviewed: 2026-11-20 Acesulfame Potassium (CAS 55589-62-3) is a high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineAcesulfame Potassium is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Acesulfame Potassium | | Parameter | Specification | Assay (dried basis) | 99.0–101.0% (HPLC) | Potassium (K) | 17.0–19.0% (titration) | Appearance | White crystalline powder | Moisture | ≤1.0% | pH (1% solution) | 5.5–7.5 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.60–0.90 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Acesulfame Potassium the identity evidence used for release is: - HPLC retention time against an Ace-K reference standard - Potassium content by titration or ICP - IR spectrum - Sulfate and fluoride where the specification requires them HPLC retention time against an Ace-K reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Acesulfame Potassium the moisture limit is ≤1.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Acesulfame Potassium can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Acesulfame Potassium specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acesulfame Potassium. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acesulfame Potassium: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Acesulfame Potassium grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/acesulfame-potassium/grades/ Reviewed: 2026-11-20 Acesulfame Potassium is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Acesulfame Potassium is no exception: Ace-K 99% powder and Ace-K granular can share an assay and still behave differently in the line. ## The grade map Acesulfame Potassium grades | | Grade | Best fit | What changes | Ace-K 99% powder | Beverages and tabletop | Standard grade | Ace-K granular | Dry blends and sachets | Better flow, lower dust | Ace-K micronized | Suspensions | Finer particle | Ace-K blend | Sweetener systems | Blend ratio and carrier must be declared ## Sweetness and taste The indicative sweetness is 180–200 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Fast onset with a bitter, metallic linger at higher doses; rarely used alone in a clean-finish beverage. The use level is 0.005–0.05% in beverages, depending on the blend. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; solutions are neutral to slightly alkaline. Low to moderate; store sealed and dry. ## The grade decision The level-four page for this product compares Ace-K alone with Ace-K with aspartame or sucralose. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Ace-K alone vs in a blend: why the aftertaste changes Ace-K's bitter linger can be reduced by blending, not by buying a different white powder with the same assay. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Acesulfame Potassium specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acesulfame Potassium. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acesulfame Potassium: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Acesulfame Potassium stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/acesulfame-potassium/stability/ Reviewed: 2026-11-20 Acesulfame Potassium is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low to moderate; store sealed and dry. The specification limits moisture to ≤1.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal pasteurisation; no meaningful loss at typical beverage process temperatures. Stable across pH 3–7; the potassium salt remains ionised in solution. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Acesulfame Potassium is added at 0.005–0.05% in beverages, depending on the blend. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; solutions are neutral to slightly alkaline. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Acesulfame Potassium specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acesulfame Potassium. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acesulfame Potassium: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Acesulfame Potassium: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/acesulfame-potassium/moq/ Reviewed: 2026-11-20 Acesulfame Potassium is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Acesulfame Potassium specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acesulfame Potassium. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acesulfame Potassium: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Acesulfame Potassium is what the specification says URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/acesulfame-potassium/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Acesulfame Potassium can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Acesulfame Potassium needs both. ## Why identity is a separate test The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC retention time against an Ace-K reference standard - Potassium content by titration or ICP - IR spectrum - Sulfate and fluoride where the specification requires them For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Sodium saccharin or another white powder blended in - A lower-assay grade sold as 99% - Carrier not declared - Potassium content outside the specification None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Acesulfame Potassium, the relevant identity format is Ace-K 99.0–101.0%, potassium 17.0–19.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Acesulfame Potassium specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acesulfame Potassium. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acesulfame Potassium: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Ace-K alone vs in a blend: why the aftertaste changes URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/acesulfame-potassium/grades/ace-k-alone-vs-blends/ Reviewed: 2026-11-20 Synergy is a formulation tool is a formulation question, not a catalogue question. Ace-K's bitter linger can be reduced by blending, not by buying a different white powder with the same assay. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineAce-K's bitter linger can be reduced by blending, not by buying a different white powder with the same assay. ## The two options Ace-K alone vs in a blend: why the aftertaste changes | | Option | What it is | Option A | Ace-K alone: low cost, fast onset, but a metallic linger that becomes obvious at higher doses. | Option B | Ace-K with aspartame or sucralose: a rounder onset and a shorter tail, at the cost of a second ingredient and a blend specification. ## Taste and sweetness The published sweetness for Acesulfame Potassium is 180–200 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Fast onset with a bitter, metallic linger at higher doses; rarely used alone in a clean-finish beverage. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Ace-K alone: low cost, fast onset, but a metallic linger that becomes obvious at higher doses. Ace-K with aspartame or sucralose: a rounder onset and a shorter tail, at the cost of a second ingredient and a blend specification. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; solutions are neutral to slightly alkaline. Stable in dry form and through normal pasteurisation; no meaningful loss at typical beverage process temperatures. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Ace-K 99% powder, Ace-K granular, Ace-K micronized, Ace-K blend. The primary specification is 99.0–101.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; solutions are neutral to slightly alkaline. 0.005–0.05% in beverages, depending on the blend is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision If the brief is a cost-sensitive beverage and the sweetness level is moderate, Ace-K alone may pass. If the tail is objectionable, design a blend and test it at the final pH; changing the supplier will not fix a molecule-level taste. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Acesulfame Potassium specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acesulfame Potassium. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acesulfame Potassium: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Aspartame: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame/coa/ Reviewed: 2026-11-20 Aspartame (CAS 22839-47-0) is a high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineAspartame is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Aspartame | | Parameter | Specification | Assay (dried basis) | 98.0–102.0% (HPLC) | L-Phenylalanine | 47.0–52.0% (HPLC) | Related substances | ≤2.0% (HPLC) | Appearance | White crystalline powder | Moisture | ≤4.5% | pH (1% solution) | 4.5–6.0 | Solubility | Sparingly soluble in water; more soluble at lower pH | Particle size | ≥95% through 80 mesh | Bulk density | 0.30–0.60 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Aspartame the identity evidence used for release is: - HPLC retention time against an aspartame reference standard - Phenylalanine content and the related-substance profile - IR spectrum and optical rotation - Diketopiperazine by HPLC where the specification requires it HPLC retention time against an aspartame reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Aspartame the moisture limit is ≤4.5%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Aspartame can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Aspartame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Aspartame grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame/grades/ Reviewed: 2026-11-20 Aspartame is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Aspartame is no exception: Aspartame 99% powder and Aspartame granular can share an assay and still behave differently in the line. ## The grade map Aspartame grades | | Grade | Best fit | What changes | Aspartame 99% powder | Beverages and tabletop | Standard grade | Aspartame granular | Dry blends and sachets | Better flow, lower dust | Encapsulated aspartame | Baked and high-heat systems | Protects the molecule through the process | Aspartame blend | Sweetener systems | Blend ratio and carrier must be declared ## Sweetness and taste The indicative sweetness is 180–220 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, sucrose-like sweetness with a slower onset than Ace-K and a shorter tail than saccharin. The use level is 0.01–0.06% in beverages, depending on the target sucrose equivalence. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Sparingly soluble in water; solubility increases at lower pH, and dissolution time matters in a beverage line. Moderate; store sealed below 25 °C. ## The grade decision The level-four page for this product compares Aspartame 99% powder with Ace-K. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Aspartame vs Ace-K: which one carries the tail Aspartame gives a sucrose-like sweetness that arrives late; Ace-K arrives fast and lingers bitter. The blend is often better than either. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Aspartame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Aspartame stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame/stability/ Reviewed: 2026-11-20 Aspartame is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderate; store sealed below 25 °C. The specification limits moisture to ≤4.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Not suited to high-heat, long-hold processes; hydrolysis and diketopiperazine formation increase with temperature and time. Most stable at pH 3–5; stability falls at neutral pH and high temperature. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Aspartame is added at 0.01–0.06% in beverages, depending on the target sucrose equivalence. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Sparingly soluble in water; solubility increases at lower pH, and dissolution time matters in a beverage line. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Aspartame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Aspartame: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame/moq/ Reviewed: 2026-11-20 Aspartame is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Aspartame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Aspartame is what the specification says URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Aspartame can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Aspartame needs both. ## Why identity is a separate test The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC retention time against an aspartame reference standard - Phenylalanine content and the related-substance profile - IR spectrum and optical rotation - Diketopiperazine by HPLC where the specification requires it For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-assay grade sold as 99% - Aspartame blended with another sweetener without declaration - Carrier not declared - A degraded lot with an elevated diketopiperazine figure None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Aspartame, the relevant identity format is Aspartame 98.0–102.0%, phenylalanine 47–52%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Aspartame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Aspartame vs Ace-K: which one carries the tail URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame/grades/aspartame-vs-ace-k/ Reviewed: 2026-11-20 Two intense sweeteners, two different curves is a formulation question, not a catalogue question. Aspartame gives a sucrose-like sweetness that arrives late; Ace-K arrives fast and lingers bitter. The blend is often better than either. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineAspartame gives a sucrose-like sweetness that arrives late; Ace-K arrives fast and lingers bitter. The blend is often better than either. ## The two options Aspartame vs Ace-K: which one carries the tail | | Option | What it is | Option A | Aspartame 99% powder: the standard catalog grade. | Option B | Ace-K: heat-stable and cheap, with a fast onset and a metallic linger at higher doses. ## Taste and sweetness The published sweetness for Aspartame is 180–220 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, sucrose-like sweetness with a slower onset than Ace-K and a shorter tail than saccharin. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Aspartame 99% powder: the standard catalog grade. Ace-K: heat-stable and cheap, with a fast onset and a metallic linger at higher doses. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Sparingly soluble in water; solubility increases at lower pH, and dissolution time matters in a beverage line. Not suited to high-heat, long-hold processes; hydrolysis and diketopiperazine formation increase with temperature and time. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Aspartame 99% powder, Aspartame granular, Encapsulated aspartame, Aspartame blend. The primary specification is 98.0–102.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Sparingly soluble in water; solubility increases at lower pH, and dissolution time matters in a beverage line. 0.01–0.06% in beverages, depending on the target sucrose equivalence is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Design the blend against the process first. If the product is pasteurised or baked, aspartame may lose too much; if it is a cold-fill beverage and the tail is the issue, a small aspartame fraction can soften the Ace-K. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Aspartame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Saccharin Sodium (Dihydrate): what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/saccharin-sodium/coa/ Reviewed: 2026-11-20 Saccharin Sodium (Dihydrate) (CAS 6155-57-3) is a high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineSaccharin Sodium (Dihydrate) is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Saccharin Sodium (Dihydrate) | | Parameter | Specification | Assay (dried basis) | 99.0–101.0% (HPLC) | Appearance | White crystalline powder or granules | Moisture | 13.5–15.0% (dihydrate) | pH (10% solution) | 5.0–8.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh; granular on request | Bulk density | 0.60–0.90 g/mL | Benzoate and salicylate | Absent by the specified test | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Saccharin Sodium (Dihydrate) the identity evidence used for release is: - HPLC retention time against a sodium saccharin standard - Assay on the dried basis, with the moisture measured separately - IR spectrum - Benzoate and salicylate limit tests HPLC retention time against a sodium saccharin standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Saccharin Sodium (Dihydrate) the moisture limit is 13.5–15.0% (dihydrate). The particle size is ≥95% through 80 mesh; granular on request. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Saccharin Sodium (Dihydrate) can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Saccharin Sodium (Dihydrate) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Saccharin Sodium (Dihydrate). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Saccharin Sodium (Dihydrate): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Saccharin Sodium (Dihydrate) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/saccharin-sodium/grades/ Reviewed: 2026-11-20 Saccharin Sodium (Dihydrate) is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Saccharin Sodium (Dihydrate) is no exception: Sodium saccharin dihydrate and Sodium saccharin anhydrous can share an assay and still behave differently in the line. ## The grade map Saccharin Sodium (Dihydrate) grades | | Grade | Best fit | What changes | Sodium saccharin dihydrate | Tabletop and general food use | Standard grade | Sodium saccharin anhydrous | Low-moisture dry blends | Different moisture and label identity | Saccharin acid | Specialty food systems | Different solubility and salt form | Granular sodium saccharin | Tabletop and sachets | Better flow, lower dust ## Sweetness and taste The indicative sweetness is 300–500 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Fast, intense sweetness with a metallic and bitter linger; rarely used alone in a premium-taste application. The use level is 0.005–0.05% in beverages, depending on the blend. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; the dihydrate loses water on heating and should not be dried before use. Low; store sealed and dry. ## The grade decision The level-four page for this product compares Sodium saccharin dihydrate with Sodium saccharin anhydrous. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Sodium saccharin vs saccharin acid: the salt and the moisture matter Sodium saccharin dihydrate carries two water molecules and a sodium ion; saccharin acid does not. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Saccharin Sodium (Dihydrate) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Saccharin Sodium (Dihydrate). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Saccharin Sodium (Dihydrate): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Saccharin Sodium (Dihydrate) stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/saccharin-sodium/stability/ Reviewed: 2026-11-20 Saccharin Sodium (Dihydrate) is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low; store sealed and dry. The specification limits moisture to 13.5–15.0% (dihydrate). Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal food processing. Stable across normal food pH; no significant hydrolysis at typical use conditions. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Saccharin Sodium (Dihydrate) is added at 0.005–0.05% in beverages, depending on the blend. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; the dihydrate loses water on heating and should not be dried before use. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Saccharin Sodium (Dihydrate) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Saccharin Sodium (Dihydrate). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Saccharin Sodium (Dihydrate): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Saccharin Sodium (Dihydrate): MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/saccharin-sodium/moq/ Reviewed: 2026-11-20 Saccharin Sodium (Dihydrate) is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Saccharin Sodium (Dihydrate) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Saccharin Sodium (Dihydrate). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Saccharin Sodium (Dihydrate): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Saccharin Sodium (Dihydrate) is what the specification says URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/saccharin-sodium/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Saccharin Sodium (Dihydrate) can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Saccharin Sodium (Dihydrate) needs both. ## Why identity is a separate test The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC retention time against a sodium saccharin standard - Assay on the dried basis, with the moisture measured separately - IR spectrum - Benzoate and salicylate limit tests For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Anhydrous saccharin sold as dihydrate without a label change - A lower-assay grade or a blended powder sold as 99% - Saccharin acid sold as the sodium salt - Carrier not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Saccharin Sodium (Dihydrate), the relevant identity format is Sodium saccharin 99.0–101.0% (dried basis), dihydrate. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Saccharin Sodium (Dihydrate) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Saccharin Sodium (Dihydrate). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Saccharin Sodium (Dihydrate): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Sodium saccharin vs saccharin acid: the salt and the moisture matter URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/saccharin-sodium/grades/saccharin-sodium-vs-acid/ Reviewed: 2026-11-20 Two grades, one application decision is a formulation question, not a catalogue question. Sodium saccharin dihydrate carries two water molecules and a sodium ion; saccharin acid does not. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineSodium saccharin dihydrate carries two water molecules and a sodium ion; saccharin acid does not. ## The two options Sodium saccharin vs saccharin acid: the salt and the moisture matter | | Option | What it is | Option A | Sodium saccharin dihydrate: freely soluble, 13.5–15% water, the common tabletop and beverage form. | Option B | Sodium saccharin anhydrous: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Saccharin Sodium (Dihydrate) is 300–500 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Fast, intense sweetness with a metallic and bitter linger; rarely used alone in a premium-taste application. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Sodium saccharin dihydrate: freely soluble, 13.5–15% water, the common tabletop and beverage form. Sodium saccharin anhydrous: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; the dihydrate loses water on heating and should not be dried before use. Stable in dry form and through normal food processing. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Sodium saccharin dihydrate, Sodium saccharin anhydrous, Saccharin acid, Granular sodium saccharin. The primary specification is 99.0–101.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; the dihydrate loses water on heating and should not be dried before use. 0.005–0.05% in beverages, depending on the blend is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision If the formula needs a freely soluble powder, the sodium salt is the practical choice; if the sodium contribution or the moisture matters, look at the anhydrous salt or the acid and re-validate the taste and solubility. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Saccharin Sodium (Dihydrate) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Saccharin Sodium (Dihydrate). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Saccharin Sodium (Dihydrate): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Neotame: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/neotame/coa/ Reviewed: 2026-11-20 Neotame (CAS 165450-17-9) is a high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineNeotame is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Neotame | | Parameter | Specification | Assay (dried basis) | 97.0–102.0% (HPLC) | Related substances | ≤2.0% (HPLC) | Appearance | White to off-white powder | Moisture | ≤5.0% | pH (0.5% solution) | 5.0–7.0 | Solubility | Sparingly soluble in water | Particle size | ≥95% through 100 mesh | Bulk density | 0.30–0.60 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Neotame the identity evidence used for release is: - HPLC retention time against a neotame reference standard - Related-substance profile - IR spectrum - Assay on the dried basis HPLC retention time against a neotame reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Neotame the moisture limit is ≤5.0%. The particle size is ≥95% through 100 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Neotame can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Neotame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neotame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neotame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Neotame grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/neotame/grades/ Reviewed: 2026-11-20 Neotame is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Neotame is no exception: Neotame 99% powder and Neotame 1% premix can share an assay and still behave differently in the line. ## The grade map Neotame grades | | Grade | Best fit | What changes | Neotame 99% powder | Beverages and food | Standard high-purity grade | Neotame 1% premix | Accurate low-dose weighing | Carrier and homogeneity must be specified | Neotame granular | Dry blends | Better flow | Neotame blend | Sweetener systems | Blend ratio and carrier must be declared ## Sweetness and taste The indicative sweetness is 7,000–13,000 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean sweetness with a slower onset and a slight linger; at very low use levels the aftertaste is less pronounced than saccharin. The use level is 0.0002–0.005% in food, depending on the category. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Sparingly soluble in water; a pre-diluted premix is usually needed at food use levels. Moderate; store sealed and dry. ## The grade decision The level-four page for this product compares Neotame 99% powder with Neotame 1% premix. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Neotame vs aspartame: potency is not the only difference Neotame is roughly 30–60 times sweeter than aspartame, so the dose is measured in parts per million and the premix becomes part of the specification. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Neotame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neotame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neotame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Neotame stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/neotame/stability/ Reviewed: 2026-11-20 Neotame is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderate; store sealed and dry. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; heat and moisture can hydrolyse the ester over time. Most stable at mildly acidic pH; high temperature and neutral pH reduce stability. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Neotame is added at 0.0002–0.005% in food, depending on the category. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Sparingly soluble in water; a pre-diluted premix is usually needed at food use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Neotame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neotame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neotame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Neotame: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/neotame/moq/ Reviewed: 2026-11-20 Neotame is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Neotame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neotame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neotame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Neotame is what the specification says URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/neotame/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Neotame can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Neotame needs both. ## Why identity is a separate test The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC retention time against a neotame reference standard - Related-substance profile - IR spectrum - Assay on the dried basis For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-assay grade or a blend sold as 99% - Aspartame substituted without declaration - Carrier not declared - A degraded lot with elevated hydrolysis products None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Neotame, the relevant identity format is Neotame 97.0–102.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Neotame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neotame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neotame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Neotame vs aspartame: potency is not the only difference URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/neotame/grades/neotame-vs-aspartame/ Reviewed: 2026-11-20 A trace-use sweetener needs a different plan is a formulation question, not a catalogue question. Neotame is roughly 30–60 times sweeter than aspartame, so the dose is measured in parts per million and the premix becomes part of the specification. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineNeotame is roughly 30–60 times sweeter than aspartame, so the dose is measured in parts per million and the premix becomes part of the specification. ## The two options Neotame vs aspartame: potency is not the only difference | | Option | What it is | Option A | Neotame 99% powder: the standard catalog grade. | Option B | Neotame 1% premix: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Neotame is 7,000–13,000 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean sweetness with a slower onset and a slight linger; at very low use levels the aftertaste is less pronounced than saccharin. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Neotame 99% powder: the standard catalog grade. Neotame 1% premix: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Sparingly soluble in water; a pre-diluted premix is usually needed at food use levels. Stable in dry form; heat and moisture can hydrolyse the ester over time. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Neotame 99% powder, Neotame 1% premix, Neotame granular, Neotame blend. The primary specification is 97.0–102.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Sparingly soluble in water; a pre-diluted premix is usually needed at food use levels. 0.0002–0.005% in food, depending on the category is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose neotame when the use rate or the cost per sweetness unit is the driver and the line can handle a micro-dose premix. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Neotame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Neotame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Neotame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Advantame: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/advantame/coa/ Reviewed: 2026-11-20 Advantame (CAS 714229-20-6) is a high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineAdvantame is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC with UV detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Advantame | | Parameter | Specification | Assay (dried basis) | 97.0–102.0% (HPLC) | Related substances | ≤2.0% (HPLC) | Appearance | White to off-white powder | Moisture | ≤5.0% | pH (0.5% solution) | 5.0–7.0 | Solubility | Sparingly soluble in water | Particle size | ≥95% through 100 mesh | Bulk density | 0.30–0.60 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Advantame the identity evidence used for release is: - HPLC retention time against an advantame reference standard - Related-substance profile - IR spectrum - Assay on the dried basis HPLC retention time against an advantame reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC with UV detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Advantame the moisture limit is ≤5.0%. The particle size is ≥95% through 100 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Advantame can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Advantame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Advantame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Advantame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Advantame grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/advantame/grades/ Reviewed: 2026-11-20 Advantame is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Advantame is no exception: Advantame 99% powder and Advantame 1% premix can share an assay and still behave differently in the line. ## The grade map Advantame grades | | Grade | Best fit | What changes | Advantame 99% powder | Beverages and food | Standard high-purity grade | Advantame 1% premix | Accurate low-dose weighing | Carrier and homogeneity must be specified | Advantame blend | Sweetener systems | Blend ratio and carrier must be declared ## Sweetness and taste The indicative sweetness is 20,000 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean sweetness with a slower onset and a long tail; use level is so low that carrier and homogeneity dominate the taste result. The use level is 0.0001–0.002% in food, depending on the category. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Sparingly soluble in water; a pre-diluted premix is needed at food use levels. Moderate; store sealed and dry. ## The grade decision The level-four page for this product compares Pure advantame with Advantame 1% premix. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Advantame at trace use levels: why the premix is the product At 20,000 times sucrose, the active is a few grams per tonne of finished food; the premix and its homogeneity decide the result. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Advantame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Advantame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Advantame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Advantame stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/advantame/stability/ Reviewed: 2026-11-20 Advantame is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderate; store sealed and dry. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; heat and moisture can hydrolyse the ester over time. Most stable at mildly acidic pH; neutral pH and high heat reduce stability. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Advantame is added at 0.0001–0.002% in food, depending on the category. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Sparingly soluble in water; a pre-diluted premix is needed at food use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Advantame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Advantame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Advantame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Advantame: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/advantame/moq/ Reviewed: 2026-11-20 Advantame is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Advantame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Advantame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Advantame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Advantame is what the specification says URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/advantame/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Advantame can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Advantame needs both. ## Why identity is a separate test The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC retention time against an advantame reference standard - Related-substance profile - IR spectrum - Assay on the dried basis For this grade, the primary assay is HPLC with UV detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-assay grade or a blend sold as 99% - Neotame or aspartame substituted without declaration - Carrier not declared - A degraded lot with elevated hydrolysis products None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Advantame, the relevant identity format is Advantame 97.0–102.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Advantame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Advantame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Advantame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Advantame at trace use levels: why the premix is the product URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/advantame/grades/advantame-use-levels/ Reviewed: 2026-11-20 A dose too small to weigh is a formulation question, not a catalogue question. At 20,000 times sucrose, the active is a few grams per tonne of finished food; the premix and its homogeneity decide the result. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineAt 20,000 times sucrose, the active is a few grams per tonne of finished food; the premix and its homogeneity decide the result. ## The two options Advantame at trace use levels: why the premix is the product | | Option | What it is | Option A | Pure advantame: highest flexibility, but a milligram-scale dose that most lines cannot weigh reproducibly. | Option B | Advantame 1% premix: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Advantame is 20,000 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean sweetness with a slower onset and a long tail; use level is so low that carrier and homogeneity dominate the taste result. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Pure advantame: highest flexibility, but a milligram-scale dose that most lines cannot weigh reproducibly. Advantame 1% premix: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Sparingly soluble in water; a pre-diluted premix is needed at food use levels. Stable in dry form; heat and moisture can hydrolyse the ester over time. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Advantame 99% powder, Advantame 1% premix, Advantame blend. The primary specification is 97.0–102.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Sparingly soluble in water; a pre-diluted premix is needed at food use levels. 0.0001–0.002% in food, depending on the category is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the batch size and the smallest accurate weighment on the line. If the active dose falls below the balance's reliable range, specify a premix and validate its homogeneity rather than asking the operator to weigh a speck of powder. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Advantame specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Advantame. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Advantame: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Sodium Cyclamate: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sodium-cyclamate/coa/ Reviewed: 2026-11-20 Sodium Cyclamate (CAS 139-05-9) is a high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineSodium Cyclamate is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC or titration. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Sodium Cyclamate | | Parameter | Specification | Assay (dried basis) | 98.0–101.0% | Cyclohexyl sulfamate | ≥98.0% | Appearance | White crystalline powder | Moisture | ≤1.0% | pH (10% solution) | 5.5–8.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.55–0.85 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Sodium Cyclamate the identity evidence used for release is: - HPLC retention time against a Sodium Cyclamate reference standard - Related-substance profile by the same method - IR spectrum and optical rotation where applicable - Ion or salt-form check where the specification names a salt HPLC retention time against a Sodium Cyclamate reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC or titration reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Sodium Cyclamate the moisture limit is ≤1.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Sodium Cyclamate can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Sodium Cyclamate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sodium Cyclamate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sodium Cyclamate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Sodium Cyclamate grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sodium-cyclamate/grades/ Reviewed: 2026-11-20 Sodium Cyclamate is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Sodium Cyclamate is no exception: Sodium cyclamate powder and Sodium cyclamate granular can share an assay and still behave differently in the line. ## The grade map Sodium Cyclamate grades | | Grade | Best fit | What changes | Sodium cyclamate powder | Beverages and tabletop | Standard grade | Sodium cyclamate granular | Dry blends and sachets | Better flow, lower dust | Calcium cyclamate | Low-sodium formulations | Different salt and label ## Sweetness and taste The indicative sweetness is 30–50 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Sweet with a slower onset and a slight bitter note; usually blended with another high-intensity sweetener. The use level is 0.02–0.15% in beverages, depending on the market and the blend. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; clear solutions at use levels. Low; store sealed and dry. ## The grade decision The level-four page for this product compares Sodium cyclamate with Sodium cyclamate granular. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Sodium vs calcium cyclamate: the salt and the sodium load The two options are different specifications, not two names for the same drum. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Sodium Cyclamate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sodium Cyclamate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sodium Cyclamate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Sodium Cyclamate stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sodium-cyclamate/stability/ Reviewed: 2026-11-20 Sodium Cyclamate is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low; store sealed and dry. The specification limits moisture to ≤1.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal food processing. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Sodium Cyclamate is added at 0.02–0.15% in beverages, depending on the market and the blend. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; clear solutions at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Sodium Cyclamate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sodium Cyclamate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sodium Cyclamate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Sodium Cyclamate: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sodium-cyclamate/moq/ Reviewed: 2026-11-20 Sodium Cyclamate is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Sodium Cyclamate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sodium Cyclamate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sodium Cyclamate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Sodium Cyclamate is what the specification says URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sodium-cyclamate/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Sodium Cyclamate can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Sodium Cyclamate needs both. ## Why identity is a separate test The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC retention time against a Sodium Cyclamate reference standard - Related-substance profile by the same method - IR spectrum and optical rotation where applicable - Ion or salt-form check where the specification names a salt For this grade, the primary assay is HPLC or titration. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-assay grade sold as Sodium Cyclamate - A different salt or sweetener blended into the lot - Carrier or bulking agent not declared - A degraded lot with an elevated related-substance figure None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Sodium Cyclamate, the relevant identity format is Sodium cyclamate 98.0–101.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Sodium Cyclamate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sodium Cyclamate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sodium Cyclamate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Sodium vs calcium cyclamate: the salt and the sodium load URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/sodium-cyclamate/grades/sodium-vs-calcium-cyclamate/ Reviewed: 2026-11-20 Same sweetener, different cation is a formulation question, not a catalogue question. The two options are different specifications, not two names for the same drum. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe two options are different specifications, not two names for the same drum. ## The two options Sodium vs calcium cyclamate: the salt and the sodium load | | Option | What it is | Option A | Sodium cyclamate: the common salt, freely soluble, adds sodium to the formula. | Option B | Sodium cyclamate granular: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Sodium Cyclamate is 30–50 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Sweet with a slower onset and a slight bitter note; usually blended with another high-intensity sweetener. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Sodium cyclamate: the common salt, freely soluble, adds sodium to the formula. Sodium cyclamate granular: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; clear solutions at use levels. Stable in dry form and through normal food processing. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Sodium cyclamate powder, Sodium cyclamate granular, Calcium cyclamate. The primary specification is 98.0–101.0%. The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; clear solutions at use levels. 0.02–0.15% in beverages, depending on the market and the blend is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the application and the process, then confirm the particle size, carrier and use level in a matrix trial. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Sodium Cyclamate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sodium Cyclamate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sodium Cyclamate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Aspartame-Acesulfame Salt (E962): what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame-acesulfame-salt/coa/ Reviewed: 2026-11-20 Aspartame-Acesulfame Salt (E962) (CAS 106372-55-8) is a high-intensity sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineAspartame-Acesulfame Salt (E962) is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC for each active. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Aspartame-Acesulfame Salt (E962) | | Parameter | Specification | Aspartame | 53.0–57.0% (HPLC) | Acesulfame | 38.0–42.0% (HPLC) | Appearance | White crystalline powder | Moisture | ≤2.0% | pH (1% solution) | 3.0–5.0 | Solubility | Sparingly soluble in water; solubility increases at lower pH | Particle size | ≥95% through 80 mesh | Bulk density | 0.30–0.60 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Aspartame-Acesulfame Salt (E962) the identity evidence used for release is: - HPLC retention time against a Aspartame-Acesulfame Salt (E962) reference standard - Related-substance profile by the same method - IR spectrum and optical rotation where applicable - Ion or salt-form check where the specification names a salt HPLC retention time against a Aspartame-Acesulfame Salt (E962) reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC for each active reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Aspartame-Acesulfame Salt (E962) the moisture limit is ≤2.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Aspartame-Acesulfame Salt (E962) can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Aspartame-Acesulfame Salt (E962) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame-Acesulfame Salt (E962). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame-Acesulfame Salt (E962): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Aspartame-Acesulfame Salt (E962) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame-acesulfame-salt/grades/ Reviewed: 2026-11-20 Aspartame-Acesulfame Salt (E962) is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Aspartame-Acesulfame Salt (E962) is no exception: E962 1:1 salt and E962 granular can share an assay and still behave differently in the line. ## The grade map Aspartame-Acesulfame Salt (E962) grades | | Grade | Best fit | What changes | E962 1:1 salt | Beverages and tabletop | Rounded sweetness | E962 granular | Dry blends and sachets | Better flow | Physical blend | Custom ratios | A different label and a different specification ## Sweetness and taste The indicative sweetness is 300–350 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Rounded sweetness with a faster onset than aspartame alone and a shorter tail than Ace-K alone. The use level is 0.01–0.03% in beverages, depending on the target sucrose equivalence. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Sparingly soluble in water; more soluble at lower pH. Moderate; store sealed below 25 °C. ## The grade decision The level-four page for this product compares E962 1 with E962 granular. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Which Aspartame-Acesulfame Salt (E962) grade fits the brief? The two options are different specifications, not two names for the same drum. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Aspartame-Acesulfame Salt (E962) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame-Acesulfame Salt (E962). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame-Acesulfame Salt (E962): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Aspartame-Acesulfame Salt (E962) stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame-acesulfame-salt/stability/ Reviewed: 2026-11-20 Aspartame-Acesulfame Salt (E962) is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderate; store sealed below 25 °C. The specification limits moisture to ≤2.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Contains aspartame; high heat and long hold can hydrolyse it. Validate the process. Most stable at mildly acidic pH; neutral pH and high heat reduce stability. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Aspartame-Acesulfame Salt (E962) is added at 0.01–0.03% in beverages, depending on the target sucrose equivalence. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Sparingly soluble in water; more soluble at lower pH. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Aspartame-Acesulfame Salt (E962) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame-Acesulfame Salt (E962). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame-Acesulfame Salt (E962): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Aspartame-Acesulfame Salt (E962): MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame-acesulfame-salt/moq/ Reviewed: 2026-11-20 Aspartame-Acesulfame Salt (E962) is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Aspartame-Acesulfame Salt (E962) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame-Acesulfame Salt (E962). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame-Acesulfame Salt (E962): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Aspartame-Acesulfame Salt (E962) is what the specification says URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame-acesulfame-salt/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Aspartame-Acesulfame Salt (E962) can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Aspartame-Acesulfame Salt (E962) needs both. ## Why identity is a separate test The active is a small, well-defined molecule, so the assay can be tight and the related-substance profile becomes the useful quality signal. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC retention time against a Aspartame-Acesulfame Salt (E962) reference standard - Related-substance profile by the same method - IR spectrum and optical rotation where applicable - Ion or salt-form check where the specification names a salt For this grade, the primary assay is HPLC for each active. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A lower-assay grade sold as Aspartame-Acesulfame Salt (E962) - A different salt or sweetener blended into the lot - Carrier or bulking agent not declared - A degraded lot with an elevated related-substance figure None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Aspartame-Acesulfame Salt (E962), the relevant identity format is Aspartame and acesulfame in a 1:1 salt. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Aspartame-Acesulfame Salt (E962) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame-Acesulfame Salt (E962). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame-Acesulfame Salt (E962): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Which Aspartame-Acesulfame Salt (E962) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/high-intensity-sweeteners/aspartame-acesulfame-salt/grades/e962-vs-separate-blend/ Reviewed: 2026-11-20 A salt is not a blend is a formulation question, not a catalogue question. The two options are different specifications, not two names for the same drum. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe two options are different specifications, not two names for the same drum. ## The two options Which Aspartame-Acesulfame Salt (E962) grade fits the brief? | | Option | What it is | Option A | E962 1:1 salt: the standard catalog grade. | Option B | E962 granular: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Aspartame-Acesulfame Salt (E962) is 300–350 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Rounded sweetness with a faster onset than aspartame alone and a shorter tail than Ace-K alone. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process E962 1:1 salt: the standard catalog grade. E962 granular: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Sparingly soluble in water; more soluble at lower pH. Contains aspartame; high heat and long hold can hydrolyse it. Validate the process. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are E962 1:1 salt, E962 granular, Physical blend. The primary specification is 53.0–57.0% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Sparingly soluble in water; more soluble at lower pH. 0.01–0.03% in beverages, depending on the target sucrose equivalence is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose a physical blend when the ratio must be customised or the market requires the two components to be declared separately. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Aspartame-Acesulfame Salt (E962) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Aspartame-Acesulfame Salt (E962). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Aspartame-Acesulfame Salt (E962): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Erythritol: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/polyols/erythritol/coa/ Reviewed: 2026-11-20 Erythritol (CAS 149-32-6) is a polyol bulk sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineErythritol is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Erythritol | | Parameter | Specification | Assay (dried basis) | 99.0–100.5% (HPLC-RI) | Appearance | White crystalline granules or powder | Moisture | ≤0.2% | pH (5% solution) | 5.0–7.0 | Solubility | Soluble in water; endothermic dissolution produces a cooling effect | Particle size | 20–60 mesh or 80 mesh powder | Bulk density | 0.60–0.90 g/mL | Reducing sugars | ≤0.3% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Erythritol the identity evidence used for release is: - HPLC-RI retention time against an erythritol reference standard - Assay and moisture on the same lot - IR spectrum - Reducing sugars and related polyols by HPLC HPLC-RI retention time against an erythritol reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Erythritol the moisture limit is ≤0.2%. The particle size is 20–60 mesh or 80 mesh powder. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Erythritol can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Erythritol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Erythritol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Erythritol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Erythritol grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/polyols/erythritol/grades/ Reviewed: 2026-11-20 Erythritol is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Erythritol is no exception: Erythritol 20–60 mesh and Erythritol 80 mesh can share an assay and still behave differently in the line. ## The grade map Erythritol grades | | Grade | Best fit | What changes | Erythritol 20–60 mesh | Beverages and tabletop | Dissolves cleanly, good flow | Erythritol 80 mesh | Dry mixes and fine powders | Faster dispersion, more dust | Erythritol granular | Confectionery and chocolate | Larger crystal, different mouthfeel | Organic erythritol | Organic-certified products | Certificate and traceability required ## Sweetness and taste The indicative sweetness is 60–70% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean sweetness with a pronounced cooling effect; the cooling is desirable in mint and beverage applications and a problem in some baked goods. The use level is 2–10% in beverages and confectionery, depending on the solids and the sweetness target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; dissolution is endothermic, which produces the characteristic cooling effect. Very low; one of the least hygroscopic polyols, which helps with caking and shelf life. ## The grade decision The level-four page for this product compares Fine powder with Granular. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Erythritol powder vs granular: the crystal decides the mouthfeel Particle size changes dissolution speed, dust, flow and the cooling sensation; the assay is the same on both. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Erythritol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Erythritol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Erythritol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Erythritol stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/polyols/erythritol/stability/ Reviewed: 2026-11-20 Erythritol is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Very low; one of the least hygroscopic polyols, which helps with caking and shelf life. The specification limits moisture to ≤0.2%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal food processing; it does not brown like a reducing sugar. Stable across normal food pH; no meaningful hydrolysis. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Erythritol is added at 2–10% in beverages and confectionery, depending on the solids and the sweetness target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; dissolution is endothermic, which produces the characteristic cooling effect. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Erythritol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Erythritol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Erythritol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Erythritol: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/polyols/erythritol/moq/ Reviewed: 2026-11-20 Erythritol is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Erythritol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Erythritol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Erythritol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Erythritol is what the specification says URL: https://sweeteners.rainwoodbio.com/products/polyols/erythritol/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Erythritol can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Erythritol needs both. ## Why identity is a separate test The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against an erythritol reference standard - Assay and moisture on the same lot - IR spectrum - Reducing sugars and related polyols by HPLC For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltitol or sorbitol blended into erythritol - A lower-assay grade with higher moisture - Sucrose or dextrose used as a bulking agent without declaration - A coarse grade sold as a fine powder None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Erythritol, the relevant identity format is Erythritol 99.0–100.5%, moisture ≤0.2%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Erythritol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Erythritol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Erythritol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Erythritol powder vs granular: the crystal decides the mouthfeel URL: https://sweeteners.rainwoodbio.com/products/polyols/erythritol/grades/erythritol-powder-vs-granular/ Reviewed: 2026-11-20 Same polyol, different crystal is a formulation question, not a catalogue question. Particle size changes dissolution speed, dust, flow and the cooling sensation; the assay is the same on both. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineParticle size changes dissolution speed, dust, flow and the cooling sensation; the assay is the same on both. ## The two options Erythritol powder vs granular: the crystal decides the mouthfeel | | Option | What it is | Option A | Fine powder: disperses quickly in a cold beverage, but dusts, cakes more easily and can feel chalky in the mouth. | Option B | Granular: free-flowing, lower dust, slower dissolution, a different cooling release in confectionery. ## Taste and sweetness The published sweetness for Erythritol is 60–70% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean sweetness with a pronounced cooling effect; the cooling is desirable in mint and beverage applications and a problem in some baked goods. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Fine powder: disperses quickly in a cold beverage, but dusts, cakes more easily and can feel chalky in the mouth. Granular: free-flowing, lower dust, slower dissolution, a different cooling release in confectionery. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; dissolution is endothermic, which produces the characteristic cooling effect. Stable in dry form and through normal food processing; it does not brown like a reducing sugar. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Erythritol 20–60 mesh, Erythritol 80 mesh, Erythritol granular, Organic erythritol. The primary specification is 99.0–100.5% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; dissolution is endothermic, which produces the characteristic cooling effect. 2–10% in beverages and confectionery, depending on the solids and the sweetness target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the fine grade for a dry beverage mix or a smooth filling; choose the granular grade for tabletop, chocolate and a process that needs flow. Taste both in the final matrix, because the cooling effect is a particle-size experience as much as a chemistry one. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Erythritol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Erythritol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Erythritol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Xylitol: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/polyols/xylitol/coa/ Reviewed: 2026-11-20 Xylitol (CAS 87-99-0) is a polyol bulk sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineXylitol is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Xylitol | | Parameter | Specification | Assay (dried basis) | 98.5–101.0% (HPLC-RI) | Appearance | White crystalline powder or granules | Moisture | ≤0.5% | pH (5% solution) | 5.0–7.0 | Solubility | Freely soluble in water; endothermic dissolution | Particle size | ≥95% through 60 mesh; 80 mesh on request | Bulk density | 0.55–0.85 g/mL | Other polyols | ≤0.5% (HPLC) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Xylitol the identity evidence used for release is: - HPLC-RI retention time against a xylitol standard - Other polyols by HPLC - IR spectrum - Moisture and assay on the same lot HPLC-RI retention time against a xylitol standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Xylitol the moisture limit is ≤0.5%. The particle size is ≥95% through 60 mesh; 80 mesh on request. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Xylitol can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Xylitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Xylitol grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/polyols/xylitol/grades/ Reviewed: 2026-11-20 Xylitol is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Xylitol is no exception: Xylitol 30–60 mesh and Xylitol 80 mesh can share an assay and still behave differently in the line. ## The grade map Xylitol grades | | Grade | Best fit | What changes | Xylitol 30–60 mesh | Confectionery and tabletop | Standard crystal | Xylitol 80 mesh | Chewing gum and fine blends | Finer particle, faster dissolution | Xylitol granular | Tabletop and sachets | Free-flowing | Liquid xylitol | Syrup lines | Solids and preservation must be specified ## Sweetness and taste The indicative sweetness is 90–100% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Sweetness close to sucrose with a strong cooling effect and a clean finish; the cooling can dominate at high dose. The use level is 2–10% in confectionery, oral care and tabletop, depending on the sweetness target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; strongly endothermic, with a cooling effect that is more pronounced than erythritol's. Hygroscopic; absorbs moisture if left exposed, so the pack and the storage matter. ## The grade decision The level-four page for this product compares Xylitol with Erythritol. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Xylitol vs erythritol: cooling, hygroscopicity and the sweet tooth Xylitol is closer to sucrose in sweetness and strongly cooling; erythritol is less sweet, less hygroscopic and also cooling. The choice is a texture decision. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Xylitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Xylitol stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/polyols/xylitol/stability/ Reviewed: 2026-11-20 Xylitol is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; absorbs moisture if left exposed, so the pack and the storage matter. The specification limits moisture to ≤0.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; it can caramelise at high temperature in the presence of moisture and heat. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Xylitol is added at 2–10% in confectionery, oral care and tabletop, depending on the sweetness target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; strongly endothermic, with a cooling effect that is more pronounced than erythritol's. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Xylitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Xylitol: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/polyols/xylitol/moq/ Reviewed: 2026-11-20 Xylitol is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Xylitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Xylitol is what the specification says URL: https://sweeteners.rainwoodbio.com/products/polyols/xylitol/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Xylitol can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Xylitol needs both. ## Why identity is a separate test The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against a xylitol standard - Other polyols by HPLC - IR spectrum - Moisture and assay on the same lot For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Sorbitol or maltitol blended into xylitol - A lower-assay grade - Sucrose or dextrose used as a bulking agent - A coarse grade sold as 80 mesh None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Xylitol, the relevant identity format is Xylitol 98.5–101.0%, other polyols ≤0.5%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Xylitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Xylitol vs erythritol: cooling, hygroscopicity and the sweet tooth URL: https://sweeteners.rainwoodbio.com/products/polyols/xylitol/grades/xylitol-vs-erythritol/ Reviewed: 2026-11-20 Two polyols, two mouthfeels is a formulation question, not a catalogue question. Xylitol is closer to sucrose in sweetness and strongly cooling; erythritol is less sweet, less hygroscopic and also cooling. The choice is a texture decision. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineXylitol is closer to sucrose in sweetness and strongly cooling; erythritol is less sweet, less hygroscopic and also cooling. The choice is a texture decision. ## The two options Xylitol vs erythritol: cooling, hygroscopicity and the sweet tooth | | Option | What it is | Option A | Xylitol: ~90–100% of sucrose sweetness, hygroscopic, strong cooling, good for gum and oral care. | Option B | Erythritol: ~60–70% of sucrose, non-hygroscopic, mild-to-strong cooling, good for a dry, stable system. ## Taste and sweetness The published sweetness for Xylitol is 90–100% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Sweetness close to sucrose with a strong cooling effect and a clean finish; the cooling can dominate at high dose. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Xylitol: ~90–100% of sucrose sweetness, hygroscopic, strong cooling, good for gum and oral care. Erythritol: ~60–70% of sucrose, non-hygroscopic, mild-to-strong cooling, good for a dry, stable system. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; strongly endothermic, with a cooling effect that is more pronounced than erythritol's. Stable in dry form; it can caramelise at high temperature in the presence of moisture and heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Xylitol 30–60 mesh, Xylitol 80 mesh, Xylitol granular, Liquid xylitol. The primary specification is 98.5–101.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; strongly endothermic, with a cooling effect that is more pronounced than erythritol's. 2–10% in confectionery, oral care and tabletop, depending on the sweetness target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the moisture and the mouthfeel. If the product needs a sucrose-like sweetness and can handle a hygroscopic powder, xylitol is the closer match. If the pack must stay dry and the sweetness can be topped up with a high-intensity sweetener, erythritol is easier. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Xylitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Sorbitol: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/polyols/sorbitol/coa/ Reviewed: 2026-11-20 Sorbitol (CAS 50-70-4) is a polyol bulk sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineSorbitol is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Sorbitol | | Parameter | Specification | Assay (dried basis) | 97.0–101.0% (HPLC-RI) | Appearance | White crystalline powder or granules | Moisture | ≤1.0% (powder) | pH (5% solution) | 4.5–7.0 | Solubility | Freely soluble in water; hygroscopic | Particle size | ≥95% through 60 mesh; granular on request | Bulk density | 0.55–0.85 g/mL | Reducing sugars | ≤0.2% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Sorbitol the identity evidence used for release is: - HPLC-RI retention time against a sorbitol standard - Assay and moisture on the same lot - Reducing sugars - IR spectrum HPLC-RI retention time against a sorbitol standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Sorbitol the moisture limit is ≤1.0% (powder). The particle size is ≥95% through 60 mesh; granular on request. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Sorbitol can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Sorbitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sorbitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sorbitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Sorbitol grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/polyols/sorbitol/grades/ Reviewed: 2026-11-20 Sorbitol is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Sorbitol is no exception: Sorbitol powder and Sorbitol granular can share an assay and still behave differently in the line. ## The grade map Sorbitol grades | | Grade | Best fit | What changes | Sorbitol powder | Tabletting and dry blends | Standard grade | Sorbitol granular | Confectionery and bakery | Better flow | Sorbitol 70% solution | Humectancy and syrup lines | Water already in the system | Sorbitol special grade | Tablet and candy | Particle and crystallinity must be specified ## Sweetness and taste The indicative sweetness is 50–60% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with a slight cooling effect and a soft mouthfeel; less sweet than xylitol. The use level is 2–15% in confectionery, bakery and oral care, depending on the function. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; strongly hygroscopic and used as a humectant as well as a sweetener. Highly hygroscopic; the powder picks up water quickly and the 70% solution is easier to handle in some lines. ## The grade decision The level-four page for this product compares Powder with 70% solution. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Sorbitol powder vs 70% solution: the water is part of the formula A 70% sorbitol solution contributes water to the batch, changes the solids and needs a preservation and storage plan. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Sorbitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sorbitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sorbitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Sorbitol stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/polyols/sorbitol/stability/ Reviewed: 2026-11-20 Sorbitol is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Highly hygroscopic; the powder picks up water quickly and the 70% solution is easier to handle in some lines. The specification limits moisture to ≤1.0% (powder). Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal processing; browning can occur at high temperature. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Sorbitol is added at 2–15% in confectionery, bakery and oral care, depending on the function. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; strongly hygroscopic and used as a humectant as well as a sweetener. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum and 250 kg drum for solution are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Sorbitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sorbitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sorbitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Sorbitol: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/polyols/sorbitol/moq/ Reviewed: 2026-11-20 Sorbitol is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum or 250 kg drum for solution, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Sorbitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sorbitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sorbitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Sorbitol is what the specification says URL: https://sweeteners.rainwoodbio.com/products/polyols/sorbitol/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Sorbitol can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Sorbitol needs both. ## Why identity is a separate test The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against a sorbitol standard - Assay and moisture on the same lot - Reducing sugars - IR spectrum For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltitol or xylitol blended into sorbitol - A lower-assay grade - Water added to a 70% solution without declaration - A powder sold as 99% with a high moisture figure None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Sorbitol, the relevant identity format is Sorbitol 97.0–101.0%, reducing sugars ≤0.2%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Sorbitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sorbitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sorbitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Sorbitol powder vs 70% solution: the water is part of the formula URL: https://sweeteners.rainwoodbio.com/products/polyols/sorbitol/grades/sorbitol-powder-vs-liquid/ Reviewed: 2026-11-20 A solution is not a powder with water added is a formulation question, not a catalogue question. A 70% sorbitol solution contributes water to the batch, changes the solids and needs a preservation and storage plan. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 70% sorbitol solution contributes water to the batch, changes the solids and needs a preservation and storage plan. ## The two options Sorbitol powder vs 70% solution: the water is part of the formula | | Option | What it is | Option A | Powder: 97–101% solids, easy to weigh, but hygroscopic and prone to caking. | Option B | 70% solution: easier to handle and disperse, lower solids per kilogram, water activity and preservation implications. ## Taste and sweetness The published sweetness for Sorbitol is 50–60% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with a slight cooling effect and a soft mouthfeel; less sweet than xylitol. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Powder: 97–101% solids, easy to weigh, but hygroscopic and prone to caking. 70% solution: easier to handle and disperse, lower solids per kilogram, water activity and preservation implications. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; strongly hygroscopic and used as a humectant as well as a sweetener. Stable in dry form and through normal processing; browning can occur at high temperature. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Sorbitol powder, Sorbitol granular, Sorbitol 70% solution, Sorbitol special grade. The primary specification is 97.0–101.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; strongly hygroscopic and used as a humectant as well as a sweetener. 2–15% in confectionery, bakery and oral care, depending on the function is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use powder when the formula needs the solids and the line can control moisture. Use the solution for humectancy in a syrup or a bakery system where the water is already part of the process, and update the solids and preservation calculations accordingly. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Sorbitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sorbitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sorbitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Maltitol: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/polyols/maltitol/coa/ Reviewed: 2026-11-20 Maltitol (CAS 585-88-6) is a polyol bulk sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineMaltitol is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Maltitol | | Parameter | Specification | Assay (dried basis) | 98.0–101.0% (HPLC-RI) | Appearance | White crystalline powder or granules | Moisture | ≤1.0% | pH (5% solution) | 4.5–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 60 mesh; granular on request | Bulk density | 0.55–0.85 g/mL | Other polyols | ≤1.0% (HPLC) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Maltitol the identity evidence used for release is: - HPLC-RI retention time against a maltitol standard - Other polyols by HPLC - Assay and moisture on the same lot - IR spectrum HPLC-RI retention time against a maltitol standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Maltitol the moisture limit is ≤1.0%. The particle size is ≥95% through 60 mesh; granular on request. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Maltitol can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Maltitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Maltitol grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/polyols/maltitol/grades/ Reviewed: 2026-11-20 Maltitol is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Maltitol is no exception: Maltitol crystal and Maltitol granular can share an assay and still behave differently in the line. ## The grade map Maltitol grades | | Grade | Best fit | What changes | Maltitol crystal | Chocolate and confectionery | Standard crystalline grade | Maltitol granular | Tabletop and dry blends | Better flow | Maltitol syrup 75% | Bakery and confectionery | Water and solids must be specified | Maltitol powder | Fine dry blends | Finer particle ## Sweetness and taste The indicative sweetness is 90% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Close to sucrose with a soft mouthfeel and little cooling; the sweetness can carry a slight malt note. The use level is 5–30% in chocolate and confectionery, depending on the sugar replacement. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; less cooling than erythritol or xylitol. Moderate; less hygroscopic than sorbitol, more than erythritol. ## The grade decision The level-four page for this product compares Maltitol with Sorbitol. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Maltitol vs sorbitol: which polyol carries the chocolate Maltitol is closer to sucrose in sweetness and mouthfeel; sorbitol is more hygroscopic and less sweet. In chocolate, that difference is the recipe. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Maltitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Maltitol stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/polyols/maltitol/stability/ Reviewed: 2026-11-20 Maltitol is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderate; less hygroscopic than sorbitol, more than erythritol. The specification limits moisture to ≤1.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; can brown at high temperature, especially in the presence of amino acids. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Maltitol is added at 5–30% in chocolate and confectionery, depending on the sugar replacement. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; less cooling than erythritol or xylitol. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Maltitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Maltitol: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/polyols/maltitol/moq/ Reviewed: 2026-11-20 Maltitol is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Maltitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Maltitol is what the specification says URL: https://sweeteners.rainwoodbio.com/products/polyols/maltitol/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Maltitol can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Maltitol needs both. ## Why identity is a separate test The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against a maltitol standard - Other polyols by HPLC - Assay and moisture on the same lot - IR spectrum For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Sorbitol or maltodextrin blended into maltitol - A lower-assay syrup solid sold as crystalline - A coarse grade sold as fine powder - Water or carrier not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Maltitol, the relevant identity format is Maltitol 98.0–101.0%, other polyols ≤1.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Maltitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Maltitol vs sorbitol: which polyol carries the chocolate URL: https://sweeteners.rainwoodbio.com/products/polyols/maltitol/grades/maltitol-vs-sorbitol/ Reviewed: 2026-11-20 Sweetness and browning are the trade is a formulation question, not a catalogue question. Maltitol is closer to sucrose in sweetness and mouthfeel; sorbitol is more hygroscopic and less sweet. In chocolate, that difference is the recipe. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineMaltitol is closer to sucrose in sweetness and mouthfeel; sorbitol is more hygroscopic and less sweet. In chocolate, that difference is the recipe. ## The two options Maltitol vs sorbitol: which polyol carries the chocolate | | Option | What it is | Option A | Maltitol: ~90% of sucrose sweetness, low cooling, good body, some browning at high heat. | Option B | Sorbitol: ~50–60% sweetness, strongly hygroscopic, useful for humectancy, less suited to a chocolate body. ## Taste and sweetness The published sweetness for Maltitol is 90% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Close to sucrose with a soft mouthfeel and little cooling; the sweetness can carry a slight malt note. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Maltitol: ~90% of sucrose sweetness, low cooling, good body, some browning at high heat. Sorbitol: ~50–60% sweetness, strongly hygroscopic, useful for humectancy, less suited to a chocolate body. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; less cooling than erythritol or xylitol. Stable in dry form; can brown at high temperature, especially in the presence of amino acids. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Maltitol crystal, Maltitol granular, Maltitol syrup 75%, Maltitol powder. The primary specification is 98.0–101.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; less cooling than erythritol or xylitol. 5–30% in chocolate and confectionery, depending on the sugar replacement is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision For a sugar-free chocolate or a baked item where sucrose-like body matters, maltitol is the usual starting point. For a humectant function in a bakery or oral-care system, sorbitol may do the job at a lower sweetness. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Maltitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Isomalt: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/polyols/isomalt/coa/ Reviewed: 2026-11-20 Isomalt (CAS 64519-82-0) is a polyol bulk sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineIsomalt is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI with the GPS/GPM ratio. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Isomalt | | Parameter | Specification | Isomalt content | ≥98.0% (HPLC-RI) | 1,6-GPS : 1,1-GPM | 43–57 : 43–57 (HPLC) | Appearance | White crystalline granules or powder | Moisture | ≤0.5% | pH (10% solution) | 4.5–7.0 | Solubility | Soluble in water; low hygroscopicity | Particle size | ≥95% through 40 mesh; powder on request | Bulk density | 0.60–0.90 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Isomalt the identity evidence used for release is: - HPLC-RI isomalt content and the GPS/GPM ratio - Moisture by Karl Fischer - IR spectrum - Particle size and bulk density HPLC-RI isomalt content and the GPS/GPM ratio is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI with the GPS/GPM ratio reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Isomalt the moisture limit is ≤0.5%. The particle size is ≥95% through 40 mesh; powder on request. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Isomalt can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Isomalt specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomalt. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomalt: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Isomalt grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/polyols/isomalt/grades/ Reviewed: 2026-11-20 Isomalt is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Isomalt is no exception: Isomalt granules and Isomalt powder can share an assay and still behave differently in the line. ## The grade map Isomalt grades | | Grade | Best fit | What changes | Isomalt granules | Hard candy and tabletop | Standard crystal | Isomalt powder | Dry blends and fillings | Finer particle | Isomalt milled | Conching and fine fillings | Specified particle distribution | Isomalt ST | Sugar-free hard candy | Specific GPS/GPM ratio ## Sweetness and taste The indicative sweetness is 45–60% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with little cooling and a clean finish; the sweetness is lower than maltitol or xylitol. The use level is 10–50% in sugar-free hard candy, depending on the recipe. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; low hygroscopicity makes it useful in hard candy and dusty environments. Low; one of the reasons it is used in hard candy and in humid climates. ## The grade decision The level-four page for this product compares Granules with Powder. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Isomalt granules vs powder: the crystal decides the candy The same isomalt at a different particle size dissolves, melts and moulds differently; the GPS/GPM ratio is the second lever. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Isomalt specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomalt. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomalt: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Isomalt stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/polyols/isomalt/stability/ Reviewed: 2026-11-20 Isomalt is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low; one of the reasons it is used in hard candy and in humid climates. The specification limits moisture to ≤0.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable at hard-candy temperatures; it does not brown like a reducing sugar. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Isomalt is added at 10–50% in sugar-free hard candy, depending on the recipe. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; low hygroscopicity makes it useful in hard candy and dusty environments. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Isomalt specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomalt. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomalt: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Isomalt: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/polyols/isomalt/moq/ Reviewed: 2026-11-20 Isomalt is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Isomalt specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomalt. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomalt: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Isomalt is what the specification says URL: https://sweeteners.rainwoodbio.com/products/polyols/isomalt/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Isomalt can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Isomalt needs both. ## Why identity is a separate test The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI isomalt content and the GPS/GPM ratio - Moisture by Karl Fischer - IR spectrum - Particle size and bulk density For this grade, the primary assay is HPLC-RI with the GPS/GPM ratio. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltitol or sorbitol blended into isomalt - A lower-isomalt grade sold as 98% - A coarse grade sold as powder - Carrier not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Isomalt, the relevant identity format is Isomalt ≥98%, GPS/GPM ratio 43–57 : 43–57. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Isomalt specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomalt. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomalt: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Isomalt granules vs powder: the crystal decides the candy URL: https://sweeteners.rainwoodbio.com/products/polyols/isomalt/grades/isomalt-granules-vs-powder/ Reviewed: 2026-11-20 Particle size is a process parameter is a formulation question, not a catalogue question. The same isomalt at a different particle size dissolves, melts and moulds differently; the GPS/GPM ratio is the second lever. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe same isomalt at a different particle size dissolves, melts and moulds differently; the GPS/GPM ratio is the second lever. ## The two options Isomalt granules vs powder: the crystal decides the candy | | Option | What it is | Option A | Granules: free-flowing, slower dissolution, good for a hard-candy cook and for tabletop. | Option B | Powder: faster dissolution, more dust, better for a fine filling or a dry blend. ## Taste and sweetness The published sweetness for Isomalt is 45–60% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with little cooling and a clean finish; the sweetness is lower than maltitol or xylitol. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Granules: free-flowing, slower dissolution, good for a hard-candy cook and for tabletop. Powder: faster dissolution, more dust, better for a fine filling or a dry blend. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; low hygroscopicity makes it useful in hard candy and dusty environments. Stable at hard-candy temperatures; it does not brown like a reducing sugar. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Isomalt granules, Isomalt powder, Isomalt milled, Isomalt ST. The primary specification is ≥98.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; low hygroscopicity makes it useful in hard candy and dusty environments. 10–50% in sugar-free hard candy, depending on the recipe is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Match the particle to the process, then lock the GPS/GPM ratio. If the candy is hazy or the batch cooks unevenly, the particle distribution and the ratio are the first two things to check, not the sweetener supplier. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Isomalt specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomalt. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomalt: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Mannitol: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/polyols/mannitol/coa/ Reviewed: 2026-11-20 Mannitol (CAS 69-65-8) is a polyol bulk sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineMannitol is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Mannitol | | Parameter | Specification | Assay (dried basis) | 98.0–101.0% (HPLC-RI) | Appearance | White crystalline powder or granules | Moisture | ≤0.5% | pH (5% solution) | 5.0–7.5 | Solubility | Soluble in water; less hygroscopic than sorbitol | Particle size | ≥95% through 60 mesh; spray-dried on request | Bulk density | 0.50–0.80 g/mL | Reducing sugars | ≤0.1% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Mannitol the identity evidence used for release is: - HPLC-RI retention time against a mannitol standard - Assay and moisture on the same lot - Reducing sugars - IR spectrum and optical rotation HPLC-RI retention time against a mannitol standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Mannitol the moisture limit is ≤0.5%. The particle size is ≥95% through 60 mesh; spray-dried on request. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Mannitol can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Mannitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Mannitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Mannitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Mannitol grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/polyols/mannitol/grades/ Reviewed: 2026-11-20 Mannitol is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Mannitol is no exception: Mannitol crystal and Mannitol powder can share an assay and still behave differently in the line. ## The grade map Mannitol grades | | Grade | Best fit | What changes | Mannitol crystal | Chewing gum and dry blends | Standard crystalline | Mannitol powder | Tabletting | Finer particle | Spray-dried mannitol | Direct compression | Better compactibility, higher cost | Granular mannitol | Chewing gum | Free-flowing ## Sweetness and taste The indicative sweetness is 50–70% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with a cooling effect and a slightly dry mouthfeel; the tablet mouthfeel is grade-dependent. The use level is 5–30% in tabletting and chewing gum, depending on the function. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; low hygroscopicity and a cooling effect, with good tablet compaction in the right grade. Low; easier to store than sorbitol or xylitol. ## The grade decision The level-four page for this product compares Mannitol with Sorbitol. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Mannitol vs sorbitol: the tablet is the difference Mannitol and sorbitol are stereoisomers, but mannitol is less hygroscopic and can be spray-dried for direct compression; sorbitol is more hygroscopic and used for humectancy. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Mannitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Mannitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Mannitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Mannitol stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/polyols/mannitol/stability/ Reviewed: 2026-11-20 Mannitol is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low; easier to store than sorbitol or xylitol. The specification limits moisture to ≤0.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal processing. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Mannitol is added at 5–30% in tabletting and chewing gum, depending on the function. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; low hygroscopicity and a cooling effect, with good tablet compaction in the right grade. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Mannitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Mannitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Mannitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Mannitol: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/polyols/mannitol/moq/ Reviewed: 2026-11-20 Mannitol is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Mannitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Mannitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Mannitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Mannitol is what the specification says URL: https://sweeteners.rainwoodbio.com/products/polyols/mannitol/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Mannitol can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Mannitol needs both. ## Why identity is a separate test The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against a mannitol standard - Assay and moisture on the same lot - Reducing sugars - IR spectrum and optical rotation For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Sorbitol or maltitol blended into mannitol - A lower-assay grade - A crystalline grade sold as spray-dried without a process change - Carrier not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Mannitol, the relevant identity format is Mannitol 98.0–101.0%, reducing sugars ≤0.1%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Mannitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Mannitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Mannitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Mannitol vs sorbitol: the tablet is the difference URL: https://sweeteners.rainwoodbio.com/products/polyols/mannitol/grades/mannitol-vs-sorbitol/ Reviewed: 2026-11-20 Two isomers, two compaction behaviours is a formulation question, not a catalogue question. Mannitol and sorbitol are stereoisomers, but mannitol is less hygroscopic and can be spray-dried for direct compression; sorbitol is more hygroscopic and used for humectancy. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineMannitol and sorbitol are stereoisomers, but mannitol is less hygroscopic and can be spray-dried for direct compression; sorbitol is more hygroscopic and used for humectancy. ## The two options Mannitol vs sorbitol: the tablet is the difference | | Option | What it is | Option A | Mannitol: low hygroscopicity, good tablet feel, spray-dried grades for direct compression. | Option B | Sorbitol: more hygroscopic, useful humectancy, lower sweetness, different compaction behaviour. ## Taste and sweetness The published sweetness for Mannitol is 50–70% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with a cooling effect and a slightly dry mouthfeel; the tablet mouthfeel is grade-dependent. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Mannitol: low hygroscopicity, good tablet feel, spray-dried grades for direct compression. Sorbitol: more hygroscopic, useful humectancy, lower sweetness, different compaction behaviour. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; low hygroscopicity and a cooling effect, with good tablet compaction in the right grade. Stable in dry form and through normal processing. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Mannitol crystal, Mannitol powder, Spray-dried mannitol, Granular mannitol. The primary specification is 98.0–101.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; low hygroscopicity and a cooling effect, with good tablet compaction in the right grade. 5–30% in tabletting and chewing gum, depending on the function is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision If the application is a tablet and the process is direct compression, start with spray-dried mannitol and validate the hardness. If the function is humectancy in a soft chew or a bakery item, sorbitol is usually the better fit. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Mannitol specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Mannitol. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Mannitol: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Lactitol Monohydrate: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/polyols/lactitol/coa/ Reviewed: 2026-11-20 Lactitol Monohydrate (CAS 81025-04-9) is a polyol bulk sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineLactitol Monohydrate is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Lactitol Monohydrate | | Parameter | Specification | Lactitol (dry basis) | ≥98.0% (HPLC-RI) | Appearance | White crystalline powder | Moisture | ≤0.5% (monohydrate basis) | pH (10% solution) | 4.5–7.0 | Solubility | Soluble in water; low hygroscopicity | Particle size | ≥95% through 60 mesh | Bulk density | 0.55–0.85 g/mL | Other polyols | ≤1.0% (HPLC-RI) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Lactitol Monohydrate the identity evidence used for release is: - HPLC-RI assay against a Lactitol Monohydrate reference standard - Other-polyol profile by the same method - Moisture by Karl Fischer or loss on drying, as specified - IR spectrum and particle-size distribution HPLC-RI assay against a Lactitol Monohydrate reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Lactitol Monohydrate the moisture limit is ≤0.5% (monohydrate basis). The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Lactitol Monohydrate can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Lactitol Monohydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactitol Monohydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactitol Monohydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Lactitol Monohydrate grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/polyols/lactitol/grades/ Reviewed: 2026-11-20 Lactitol Monohydrate is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Lactitol Monohydrate is no exception: Lactitol monohydrate and Lactitol anhydrous can share an assay and still behave differently in the line. ## The grade map Lactitol Monohydrate grades | | Grade | Best fit | What changes | Lactitol monohydrate | Chocolate and bakery | Standard crystalline grade | Lactitol anhydrous | Low-moisture dry blends | Different moisture and usable solids | Lactitol granular | Tabletop and dry mixes | Better flow ## Sweetness and taste The indicative sweetness is 30–40% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild, clean sweetness with little cooling; useful where a sugar-like body is wanted without the sweetness of maltitol. The use level is 5–30% in chocolate, bakery and confectionery, depending on the sugar replacement. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; low hygroscopicity and a clean, mild sweetness. Low; easier to store than sorbitol or xylitol. ## The grade decision The level-four page for this product compares Lactitol monohydrate with Lactitol anhydrous. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Lactitol monohydrate vs anhydrous: the water is part of the specification The monohydrate carries water of crystallisation; the anhydrous grade does not. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Lactitol Monohydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactitol Monohydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactitol Monohydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Lactitol Monohydrate stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/polyols/lactitol/stability/ Reviewed: 2026-11-20 Lactitol Monohydrate is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low; easier to store than sorbitol or xylitol. The specification limits moisture to ≤0.5% (monohydrate basis). Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal processing; it does not brown like a reducing sugar. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Lactitol Monohydrate is added at 5–30% in chocolate, bakery and confectionery, depending on the sugar replacement. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; low hygroscopicity and a clean, mild sweetness. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Lactitol Monohydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactitol Monohydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactitol Monohydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Lactitol Monohydrate: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/polyols/lactitol/moq/ Reviewed: 2026-11-20 Lactitol Monohydrate is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Lactitol Monohydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactitol Monohydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactitol Monohydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Lactitol Monohydrate is what the specification says URL: https://sweeteners.rainwoodbio.com/products/polyols/lactitol/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Lactitol Monohydrate can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Lactitol Monohydrate needs both. ## Why identity is a separate test The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI assay against a Lactitol Monohydrate reference standard - Other-polyol profile by the same method - Moisture by Karl Fischer or loss on drying, as specified - IR spectrum and particle-size distribution For this grade, the primary assay is HPLC-RI. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A different polyol blended into Lactitol Monohydrate - A lower-assay grade or a higher-moisture lot - Sucrose or dextrose used as a bulking agent without declaration - A coarse grade sold as a fine powder None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Lactitol Monohydrate, the relevant identity format is Lactitol ≥98%, monohydrate. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Lactitol Monohydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactitol Monohydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactitol Monohydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Lactitol monohydrate vs anhydrous: the water is part of the specification URL: https://sweeteners.rainwoodbio.com/products/polyols/lactitol/grades/lactitol-anhydrous-vs-monohydrate/ Reviewed: 2026-11-20 Same polyol, different water is a formulation question, not a catalogue question. The monohydrate carries water of crystallisation; the anhydrous grade does not. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe monohydrate carries water of crystallisation; the anhydrous grade does not. ## The two options Lactitol monohydrate vs anhydrous: the water is part of the specification | | Option | What it is | Option A | Lactitol monohydrate: stable crystal, easier to handle, lower usable solids per kilogram. | Option B | Lactitol anhydrous: higher usable solids, more hygroscopic, better for a low-moisture blend. ## Taste and sweetness The published sweetness for Lactitol Monohydrate is 30–40% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild, clean sweetness with little cooling; useful where a sugar-like body is wanted without the sweetness of maltitol. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Lactitol monohydrate: stable crystal, easier to handle, lower usable solids per kilogram. Lactitol anhydrous: higher usable solids, more hygroscopic, better for a low-moisture blend. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; low hygroscopicity and a clean, mild sweetness. Stable in dry form and through normal processing; it does not brown like a reducing sugar. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Lactitol monohydrate, Lactitol anhydrous, Lactitol granular. The primary specification is ≥98.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; low hygroscopicity and a clean, mild sweetness. 5–30% in chocolate, bakery and confectionery, depending on the sugar replacement is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the monohydrate for general food use. Choose the anhydrous grade when the formula has a strict moisture limit and the solids matter. Do not substitute one for the other without recalculating the water and the sweetness. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Lactitol Monohydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactitol Monohydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactitol Monohydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Hydrogenated Starch Hydrolysates (HSH): what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/polyols/hydrogenated-starch-hydrolysate/coa/ Reviewed: 2026-11-20 Hydrogenated Starch Hydrolysates (HSH) (CAS —) is a polyol bulk sweetener. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineHydrogenated Starch Hydrolysates (HSH) is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI for the polyol distribution. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Hydrogenated Starch Hydrolysates (HSH) | | Parameter | Specification | Total polyols (dry basis) | ≥95.0% (HPLC-RI) | Solids | 74.0–76.0% (refractometer) | Sorbitol | 10.0–20.0% (HPLC-RI) | Maltitol | 30.0–50.0% (HPLC-RI) | Appearance | Colourless to light yellow syrup | pH (10% solution) | 4.5–7.0 | Ash | ≤0.1% | Viscosity | Specified at 25 °C for the grade | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Hydrogenated Starch Hydrolysates (HSH) the identity evidence used for release is: - HPLC-RI assay against a Hydrogenated Starch Hydrolysates (HSH) reference standard - Other-polyol profile by the same method - Moisture by Karl Fischer or loss on drying, as specified - IR spectrum and particle-size distribution HPLC-RI assay against a Hydrogenated Starch Hydrolysates (HSH) reference standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI for the polyol distribution reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Hydrogenated Starch Hydrolysates (HSH) the moisture limit is stated on the specification. The particle size is stated on the specification. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Hydrogenated Starch Hydrolysates (HSH) can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Hydrogenated Starch Hydrolysates (HSH) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Hydrogenated Starch Hydrolysates (HSH). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Hydrogenated Starch Hydrolysates (HSH): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Hydrogenated Starch Hydrolysates (HSH) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/polyols/hydrogenated-starch-hydrolysate/grades/ Reviewed: 2026-11-20 Hydrogenated Starch Hydrolysates (HSH) is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Hydrogenated Starch Hydrolysates (HSH) is no exception: HSH syrup 75% and HSH powder can share an assay and still behave differently in the line. ## The grade map Hydrogenated Starch Hydrolysates (HSH) grades | | Grade | Best fit | What changes | HSH syrup 75% | Candy, bakery and ice cream | Water and solids in the syrup | HSH powder | Dry blends | Hygroscopic; confirm flow | Custom HSH | Ratio-specific systems | Polyol distribution must be specified ## Sweetness and taste The indicative sweetness is 30–50% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with body and humectancy; less cooling than erythritol or xylitol. The use level is 5–40% in sugar-free candy, bakery and ice cream, depending on the solids target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Fully soluble in water; supplied as a syrup. The syrup contains water; the bulk powder is hygroscopic. Store sealed. ## The grade decision The level-four page for this product compares Syrup with Powder. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. HSH syrup vs powder: the water and the solids A 75% HSH syrup contributes water and a different solids figure per kilogram than a powder; the batch sheet must use the form supplied. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Hydrogenated Starch Hydrolysates (HSH) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Hydrogenated Starch Hydrolysates (HSH). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Hydrogenated Starch Hydrolysates (HSH): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Hydrogenated Starch Hydrolysates (HSH) stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/polyols/hydrogenated-starch-hydrolysate/stability/ Reviewed: 2026-11-20 Hydrogenated Starch Hydrolysates (HSH) is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability The syrup contains water; the bulk powder is hygroscopic. Store sealed. The specification limits moisture to the stated limit. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in normal processing; colour should be checked after high heat. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Hydrogenated Starch Hydrolysates (HSH) is added at 5–40% in sugar-free candy, bakery and ice cream, depending on the solids target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Fully soluble in water; supplied as a syrup. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Hydrogenated Starch Hydrolysates (HSH) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Hydrogenated Starch Hydrolysates (HSH). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Hydrogenated Starch Hydrolysates (HSH): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Hydrogenated Starch Hydrolysates (HSH): MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/polyols/hydrogenated-starch-hydrolysate/moq/ Reviewed: 2026-11-20 Hydrogenated Starch Hydrolysates (HSH) is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Hydrogenated Starch Hydrolysates (HSH) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Hydrogenated Starch Hydrolysates (HSH). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Hydrogenated Starch Hydrolysates (HSH): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Hydrogenated Starch Hydrolysates (HSH) is what the specification says URL: https://sweeteners.rainwoodbio.com/products/polyols/hydrogenated-starch-hydrolysate/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Hydrogenated Starch Hydrolysates (HSH) can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Hydrogenated Starch Hydrolysates (HSH) needs both. ## Why identity is a separate test The active is a hydrogenated sugar, so assay, moisture and the other-polyol profile belong together; the crystal form is part of the specification, not a packing detail. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI assay against a Hydrogenated Starch Hydrolysates (HSH) reference standard - Other-polyol profile by the same method - Moisture by Karl Fischer or loss on drying, as specified - IR spectrum and particle-size distribution For this grade, the primary assay is HPLC-RI for the polyol distribution. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - A different polyol blended into Hydrogenated Starch Hydrolysates (HSH) - A lower-assay grade or a higher-moisture lot - Sucrose or dextrose used as a bulking agent without declaration - A coarse grade sold as a fine powder None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Hydrogenated Starch Hydrolysates (HSH), the relevant identity format is Total polyols ≥95%, solids 74–76%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Hydrogenated Starch Hydrolysates (HSH) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Hydrogenated Starch Hydrolysates (HSH). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Hydrogenated Starch Hydrolysates (HSH): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 HSH syrup vs powder: the water and the solids URL: https://sweeteners.rainwoodbio.com/products/polyols/hydrogenated-starch-hydrolysate/grades/hsh-syrup-vs-powder/ Reviewed: 2026-11-20 A syrup is part of the formula is a formulation question, not a catalogue question. A 75% HSH syrup contributes water and a different solids figure per kilogram than a powder; the batch sheet must use the form supplied. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 75% HSH syrup contributes water and a different solids figure per kilogram than a powder; the batch sheet must use the form supplied. ## The two options HSH syrup vs powder: the water and the solids | | Option | What it is | Option A | Syrup: easier to pump and disperse, water already in the process, preservation and storage implications. | Option B | Powder: higher solids per kilogram, easier for a dry blend, but hygroscopic and prone to caking. ## Taste and sweetness The published sweetness for Hydrogenated Starch Hydrolysates (HSH) is 30–50% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with body and humectancy; less cooling than erythritol or xylitol. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Syrup: easier to pump and disperse, water already in the process, preservation and storage implications. Powder: higher solids per kilogram, easier for a dry blend, but hygroscopic and prone to caking. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Fully soluble in water; supplied as a syrup. Stable in normal processing; colour should be checked after high heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are HSH syrup 75%, HSH powder, Custom HSH. The primary specification is ≥95.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Fully soluble in water; supplied as a syrup. 5–40% in sugar-free candy, bakery and ice cream, depending on the solids target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use the syrup in a candy, bakery or ice-cream process where the water is part of the recipe. Use the powder for a dry blend where the moisture is controlled, and recalculate the polyol dose on a solids basis. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Hydrogenated Starch Hydrolysates (HSH) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Hydrogenated Starch Hydrolysates (HSH). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Hydrogenated Starch Hydrolysates (HSH): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Allulose: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/allulose/coa/ Reviewed: 2026-11-20 Allulose (CAS 551-68-8) is a rare sugar. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineAllulose is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Allulose | | Parameter | Specification | Assay (dried basis) | 98.0–102.0% (HPLC-RI) | Appearance | White crystalline powder | Moisture | ≤1.0% | pH (10% solution) | 4.0–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 60 mesh | Bulk density | 0.50–0.80 g/mL | Other sugars | ≤1.0% (HPLC) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Allulose the identity evidence used for release is: - HPLC-RI retention time against an allulose standard - Other sugars by HPLC - Optical rotation and IR - Moisture and assay on the same lot HPLC-RI retention time against an allulose standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Allulose the moisture limit is ≤1.0%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Allulose can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Allulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Allulose grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/allulose/grades/ Reviewed: 2026-11-20 Allulose is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Allulose is no exception: Allulose crystalline and Allulose powder, fine can share an assay and still behave differently in the line. ## The grade map Allulose grades | | Grade | Best fit | What changes | Allulose crystalline | Bakery, frozen dessert, tabletop | Browning and bulk | Allulose powder, fine | Dry blends | Faster dispersion | Allulose liquid 70% | Beverage and syrup lines | Solids and preservation must be specified | Organic allulose | Organic-certified products | Certificate and traceability required ## Sweetness and taste The indicative sweetness is 60–70% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean sweetness close to sucrose with a slightly slower onset and a clean finish; it browns and bulks like a sugar. The use level is 2–10% in beverages and bakery, depending on the sugar replacement. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; solutions are clean and compatible with beverage processing. Low; the crystalline grade is easy to store compared with fructose or sorbitol. ## The grade decision The level-four page for this product compares Crystalline with Liquid 70%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Allulose crystalline vs liquid: browning, solids and the line A 70% allulose syrup is not 70% of the sweetness of the crystal per kilogram; it carries water that changes solids, preservation and browning. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Allulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Allulose stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/allulose/stability/ Reviewed: 2026-11-20 Allulose is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low; the crystalline grade is easy to store compared with fructose or sorbitol. The specification limits moisture to ≤1.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Participates in browning and caramelisation, which is useful in bakery and a consideration in clear beverages. Stable across normal food pH; colour development should be checked at high heat. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Allulose is added at 2–10% in beverages and bakery, depending on the sugar replacement. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; solutions are clean and compatible with beverage processing. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Allulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Allulose: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/allulose/moq/ Reviewed: 2026-11-20 Allulose is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Allulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Allulose is what the specification says URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/allulose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Allulose can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Allulose needs both. ## Why identity is a separate test The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against an allulose standard - Other sugars by HPLC - Optical rotation and IR - Moisture and assay on the same lot For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Fructose, dextrose or sucrose blended into allulose - A lower-assay liquid sold as crystalline solids - A rare-sugar blend presented as pure allulose - Carrier not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Allulose, the relevant identity format is Allulose 98.0–102.0%, other sugars ≤1.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Allulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Allulose crystalline vs liquid: browning, solids and the line URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/allulose/grades/allulose-crystalline-vs-liquid/ Reviewed: 2026-11-20 The water changes the calculation is a formulation question, not a catalogue question. A 70% allulose syrup is not 70% of the sweetness of the crystal per kilogram; it carries water that changes solids, preservation and browning. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 70% allulose syrup is not 70% of the sweetness of the crystal per kilogram; it carries water that changes solids, preservation and browning. ## The two options Allulose crystalline vs liquid: browning, solids and the line | | Option | What it is | Option A | Crystalline: 98–102% solids, easy to weigh, best for dry blends and bakery. | Option B | Liquid 70%: easier to pump, lower solids, water activity and preservation implications. ## Taste and sweetness The published sweetness for Allulose is 60–70% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean sweetness close to sucrose with a slightly slower onset and a clean finish; it browns and bulks like a sugar. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Crystalline: 98–102% solids, easy to weigh, best for dry blends and bakery. Liquid 70%: easier to pump, lower solids, water activity and preservation implications. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; solutions are clean and compatible with beverage processing. Participates in browning and caramelisation, which is useful in bakery and a consideration in clear beverages. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Allulose crystalline, Allulose powder, fine, Allulose liquid 70%, Organic allulose. The primary specification is 98.0–102.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; solutions are clean and compatible with beverage processing. 2–10% in beverages and bakery, depending on the sugar replacement is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use crystalline allulose when the formula needs the solids and the browning is part of the bake. Use the liquid when the line is already liquid and the water is accounted for in the batch sheet, then re-check the colour and the preservation. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Allulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Tagatose: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/tagatose/coa/ Reviewed: 2026-11-20 Tagatose (CAS 87-81-0) is a rare sugar. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineTagatose is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Tagatose | | Parameter | Specification | Assay (dried basis) | 98.0–102.0% (HPLC-RI) | Appearance | White crystalline powder | Moisture | ≤1.0% | pH (10% solution) | 4.0–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 60 mesh | Bulk density | 0.50–0.80 g/mL | Other sugars | ≤1.0% (HPLC) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Tagatose the identity evidence used for release is: - HPLC-RI retention time against a tagatose standard - Other sugars by HPLC - Optical rotation and IR - Moisture and assay on the same lot HPLC-RI retention time against a tagatose standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Tagatose the moisture limit is ≤1.0%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Tagatose can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Tagatose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Tagatose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Tagatose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Tagatose grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/tagatose/grades/ Reviewed: 2026-11-20 Tagatose is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Tagatose is no exception: Tagatose crystalline and Tagatose fine powder can share an assay and still behave differently in the line. ## The grade map Tagatose grades | | Grade | Best fit | What changes | Tagatose crystalline | Beverages, confectionery, tabletop | Standard grade | Tagatose fine powder | Dry blends | Faster dispersion | Tagatose granular | Tabletop and sachets | Better flow ## Sweetness and taste The indicative sweetness is 90% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Sucrose-like sweetness with a slight cooling effect and a clean finish; at high dose a subtle fruit note can appear. The use level is 2–10% in beverages and confectionery, depending on the sugar replacement. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; clean solutions at use levels. Low to moderate; store sealed. ## The grade decision The level-four page for this product compares Tagatose with Allulose. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Tagatose vs allulose: two rare sugars, two formulation profiles Tagatose is closer to sucrose in sweetness; allulose is less sweet and browns more readily. Both need a market-status check before launch. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Tagatose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Tagatose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Tagatose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Tagatose stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/tagatose/stability/ Reviewed: 2026-11-20 Tagatose is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low to moderate; store sealed. The specification limits moisture to ≤1.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Participates in browning and caramelisation, useful in bakery and confectionery. Stable across normal food pH; browning should be checked at high heat. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Tagatose is added at 2–10% in beverages and confectionery, depending on the sugar replacement. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; clean solutions at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Tagatose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Tagatose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Tagatose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Tagatose: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/tagatose/moq/ Reviewed: 2026-11-20 Tagatose is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Tagatose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Tagatose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Tagatose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Tagatose is what the specification says URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/tagatose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Tagatose can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Tagatose needs both. ## Why identity is a separate test The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against a tagatose standard - Other sugars by HPLC - Optical rotation and IR - Moisture and assay on the same lot For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Fructose, dextrose or sucrose blended into tagatose - A lower-assay grade sold as 99% - A rare-sugar blend presented as pure tagatose - Carrier not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Tagatose, the relevant identity format is Tagatose 98.0–102.0%, other sugars ≤1.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Tagatose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Tagatose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Tagatose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Tagatose vs allulose: two rare sugars, two formulation profiles URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/tagatose/grades/tagatose-vs-allulose/ Reviewed: 2026-11-20 Similar bulk, different sweetness and browning is a formulation question, not a catalogue question. Tagatose is closer to sucrose in sweetness; allulose is less sweet and browns more readily. Both need a market-status check before launch. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineTagatose is closer to sucrose in sweetness; allulose is less sweet and browns more readily. Both need a market-status check before launch. ## The two options Tagatose vs allulose: two rare sugars, two formulation profiles | | Option | What it is | Option A | Tagatose: ~90% of sucrose sweetness, clean, some cooling, useful where a sucrose-like taste is the target. | Option B | Allulose: ~60–70% of sucrose, stronger browning, useful in bakery and frozen desserts where colour and body matter. ## Taste and sweetness The published sweetness for Tagatose is 90% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Sucrose-like sweetness with a slight cooling effect and a clean finish; at high dose a subtle fruit note can appear. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Tagatose: ~90% of sucrose sweetness, clean, some cooling, useful where a sucrose-like taste is the target. Allulose: ~60–70% of sucrose, stronger browning, useful in bakery and frozen desserts where colour and body matter. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; clean solutions at use levels. Participates in browning and caramelisation, useful in bakery and confectionery. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Tagatose crystalline, Tagatose fine powder, Tagatose granular. The primary specification is 98.0–102.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; clean solutions at use levels. 2–10% in beverages and confectionery, depending on the sugar replacement is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Match the sugar to the function. If sweetness is the main job, tagatose is closer to sucrose; if browning and bulk are the main job, allulose is the stronger tool. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Tagatose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Tagatose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Tagatose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Trehalose Dihydrate: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/trehalose/coa/ Reviewed: 2026-11-20 Trehalose Dihydrate (CAS 6138-23-4) is a rare sugar. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineTrehalose Dihydrate is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Trehalose Dihydrate | | Parameter | Specification | Assay (dried basis) | 98.0–101.0% (HPLC-RI) | Appearance | White crystalline powder | Moisture | 9.0–11.0% (dihydrate) | pH (10% solution) | 4.5–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 60 mesh | Bulk density | 0.55–0.85 g/mL | Other sugars | ≤1.0% (HPLC) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Trehalose Dihydrate the identity evidence used for release is: - HPLC-RI retention time against a trehalose standard - Moisture by Karl Fischer, to confirm the dihydrate - Other sugars by HPLC - Optical rotation and IR HPLC-RI retention time against a trehalose standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Trehalose Dihydrate the moisture limit is 9.0–11.0% (dihydrate). The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Trehalose Dihydrate can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Trehalose Dihydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Trehalose Dihydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Trehalose Dihydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Trehalose Dihydrate grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/trehalose/grades/ Reviewed: 2026-11-20 Trehalose Dihydrate is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Trehalose Dihydrate is no exception: Trehalose dihydrate and Trehalose anhydrous can share an assay and still behave differently in the line. ## The grade map Trehalose Dihydrate grades | | Grade | Best fit | What changes | Trehalose dihydrate | Bakery, beverage, protein systems | Standard crystalline | Trehalose anhydrous | Low-moisture dry blends | Different moisture and usable solids | Trehalose fine powder | Dry blends | Faster dispersion | Trehalose liquid | Syrup lines | Solids and preservation must be specified ## Sweetness and taste The indicative sweetness is 45% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild, clean sweetness with no strong cooling; at high dose it can add body rather than sweetness. The use level is 2–10% in beverages, bakery and protein systems, depending on the function. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; low hygroscopicity and a clean, mild sweetness. Low; the dihydrate is easier to handle than fructose or sorbitol. ## The grade decision The level-four page for this product compares Dihydrate with Anhydrous. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Trehalose dihydrate vs anhydrous: the water is in the specification Trehalose dihydrate carries about 9–11% water of crystallisation. An anhydrous grade does not. The batch calculation must use the form supplied. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Trehalose Dihydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Trehalose Dihydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Trehalose Dihydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Trehalose Dihydrate stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/trehalose/stability/ Reviewed: 2026-11-20 Trehalose Dihydrate is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low; the dihydrate is easier to handle than fructose or sorbitol. The specification limits moisture to 9.0–11.0% (dihydrate). Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal food processing; the dihydrate releases water at elevated temperature. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Trehalose Dihydrate is added at 2–10% in beverages, bakery and protein systems, depending on the function. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; low hygroscopicity and a clean, mild sweetness. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Trehalose Dihydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Trehalose Dihydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Trehalose Dihydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Trehalose Dihydrate: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/trehalose/moq/ Reviewed: 2026-11-20 Trehalose Dihydrate is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Trehalose Dihydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Trehalose Dihydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Trehalose Dihydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Trehalose Dihydrate is what the specification says URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/trehalose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Trehalose Dihydrate can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Trehalose Dihydrate needs both. ## Why identity is a separate test The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against a trehalose standard - Moisture by Karl Fischer, to confirm the dihydrate - Other sugars by HPLC - Optical rotation and IR For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Anhydrous trehalose sold as dihydrate without declaration - Maltodextrin, dextrose or sucrose used as a bulking agent - A lower-assay grade - A trehalose blend presented as pure None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Trehalose Dihydrate, the relevant identity format is Trehalose 98.0–101.0%, dihydrate moisture 9–11%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Trehalose Dihydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Trehalose Dihydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Trehalose Dihydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Trehalose dihydrate vs anhydrous: the water is in the specification URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/trehalose/grades/trehalose-dihydrate-vs-anhydrous/ Reviewed: 2026-11-20 Two forms, two usable solids figures is a formulation question, not a catalogue question. Trehalose dihydrate carries about 9–11% water of crystallisation. An anhydrous grade does not. The batch calculation must use the form supplied. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineTrehalose dihydrate carries about 9–11% water of crystallisation. An anhydrous grade does not. The batch calculation must use the form supplied. ## The two options Trehalose dihydrate vs anhydrous: the water is in the specification | | Option | What it is | Option A | Dihydrate: stable crystal, 9–11% moisture, easier to handle in ambient conditions, lower usable solids per kilogram. | Option B | Anhydrous: higher usable solids, more hygroscopic, better for a low-moisture dry blend. ## Taste and sweetness The published sweetness for Trehalose Dihydrate is 45% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild, clean sweetness with no strong cooling; at high dose it can add body rather than sweetness. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Dihydrate: stable crystal, 9–11% moisture, easier to handle in ambient conditions, lower usable solids per kilogram. Anhydrous: higher usable solids, more hygroscopic, better for a low-moisture dry blend. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; low hygroscopicity and a clean, mild sweetness. Stable in dry form and through normal food processing; the dihydrate releases water at elevated temperature. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Trehalose dihydrate, Trehalose anhydrous, Trehalose fine powder, Trehalose liquid. The primary specification is 98.0–101.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; low hygroscopicity and a clean, mild sweetness. 2–10% in beverages, bakery and protein systems, depending on the function is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the dihydrate for general food use and a stable crystal. Choose the anhydrous grade when the formula has a strict moisture limit and the solids matter. Do not substitute one for the other without recalculating the water and the sweetness. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Trehalose Dihydrate specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Trehalose Dihydrate. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Trehalose Dihydrate: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 L-Arabinose: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/l-arabinose/coa/ Reviewed: 2026-11-20 L-Arabinose (CAS 5328-37-0) is a rare sugar. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineL-Arabinose is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · L-Arabinose | | Parameter | Specification | Assay (dried basis) | 98.0–101.0% (HPLC-RI) | Appearance | White crystalline powder | Moisture | ≤0.5% | pH (5% solution) | 4.0–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 60 mesh | Bulk density | 0.50–0.80 g/mL | Other sugars | ≤1.0% (HPLC) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For L-Arabinose the identity evidence used for release is: - HPLC-RI retention time against an L-arabinose standard - Other sugars by HPLC - Optical rotation - IR spectrum HPLC-RI retention time against an L-arabinose standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For L-Arabinose the moisture limit is ≤0.5%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. L-Arabinose can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: L-Arabinose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for L-Arabinose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is L-Arabinose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which L-Arabinose grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/l-arabinose/grades/ Reviewed: 2026-11-20 L-Arabinose is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. L-Arabinose is no exception: L-Arabinose 99% and L-Arabinose fine powder can share an assay and still behave differently in the line. ## The grade map L-Arabinose grades | | Grade | Best fit | What changes | L-Arabinose 99% | Sweetness modification and food use | Standard grade | L-Arabinose fine powder | Dry blends | Faster dispersion | L-Arabinose granular | Tabletop and sachets | Better flow ## Sweetness and taste The indicative sweetness is 40–50% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild, clean sweetness with a slight cooling effect; used at low levels as a sweetness modifier rather than a bulk sweetener. The use level is 0.5–5% in beverages and food, depending on the function. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; clean solutions at use levels. Moderate; store sealed and dry. ## The grade decision The level-four page for this product compares L-Arabinose as a modifier with L-Arabinose as a bulk sugar. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. L-Arabinose as a sweetness modifier: dose before bulk L-Arabinose is only about half as sweet as sucrose. It is used at low levels to change the sweetness profile, not as a kilogram-for-kilogram sugar replacement. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: L-Arabinose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for L-Arabinose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is L-Arabinose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 L-Arabinose stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/l-arabinose/stability/ Reviewed: 2026-11-20 L-Arabinose is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderate; store sealed and dry. The specification limits moisture to ≤0.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal food processing. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does L-Arabinose is added at 0.5–5% in beverages and food, depending on the function. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; clean solutions at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: L-Arabinose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for L-Arabinose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is L-Arabinose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 L-Arabinose: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/l-arabinose/moq/ Reviewed: 2026-11-20 L-Arabinose is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: L-Arabinose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for L-Arabinose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is L-Arabinose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove L-Arabinose is what the specification says URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/l-arabinose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. L-Arabinose can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. L-Arabinose needs both. ## Why identity is a separate test The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against an L-arabinose standard - Other sugars by HPLC - Optical rotation - IR spectrum For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - D-Xylose or D-glucose blended into L-arabinose - A lower-assay grade - Carrier not declared - A racemic arabinose presented as the L enantiomer None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For L-Arabinose, the relevant identity format is L-Arabinose 98.0–101.0%, other sugars ≤1.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: L-Arabinose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for L-Arabinose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is L-Arabinose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 L-Arabinose as a sweetness modifier: dose before bulk URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/l-arabinose/grades/l-arabinose-sweetness-modifier/ Reviewed: 2026-11-20 A low-sweetness sugar used for what it changes is a formulation question, not a catalogue question. L-Arabinose is only about half as sweet as sucrose. It is used at low levels to change the sweetness profile, not as a kilogram-for-kilogram sugar replacement. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineL-Arabinose is only about half as sweet as sucrose. It is used at low levels to change the sweetness profile, not as a kilogram-for-kilogram sugar replacement. ## The two options L-Arabinose as a sweetness modifier: dose before bulk | | Option | What it is | Option A | L-Arabinose as a modifier: 0.5–5% in the formula, changing the onset and the tail of the sweetness. | Option B | L-Arabinose as a bulk sugar: a larger dose, a lower sweetness and a different cost per sweetness unit. ## Taste and sweetness The published sweetness for L-Arabinose is 40–50% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild, clean sweetness with a slight cooling effect; used at low levels as a sweetness modifier rather than a bulk sweetener. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process L-Arabinose as a modifier: 0.5–5% in the formula, changing the onset and the tail of the sweetness. L-Arabinose as a bulk sugar: a larger dose, a lower sweetness and a different cost per sweetness unit. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; clean solutions at use levels. Stable in dry form and through normal food processing. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are L-Arabinose 99%, L-Arabinose fine powder, L-Arabinose granular. The primary specification is 98.0–101.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; clean solutions at use levels. 0.5–5% in beverages and food, depending on the function is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the function. If the brief is a reduced-sugar beverage with a clean sweetness, test L-arabinose at 0.5–2% alongside the main sweetener. If the brief is bulk replacement, calculate the cost per sweetness unit before scaling, because the low sweetness makes it an expensive bulk option. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: L-Arabinose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for L-Arabinose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is L-Arabinose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 D-Xylose: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/d-xylose/coa/ Reviewed: 2026-11-20 D-Xylose (CAS 58-86-6) is a rare sugar. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineD-Xylose is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI or HPLC with refractive index detection. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · D-Xylose | | Parameter | Specification | Assay (dried basis) | 98.0–101.0% (HPLC-RI) | Appearance | White crystalline powder | Moisture | ≤0.5% | pH (5% solution) | 4.0–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 60 mesh | Bulk density | 0.50–0.80 g/mL | Other sugars | ≤1.0% (HPLC) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For D-Xylose the identity evidence used for release is: - HPLC-RI retention time against a D-xylose standard - Other sugars by HPLC - Optical rotation - IR spectrum HPLC-RI retention time against a D-xylose standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI or HPLC with refractive index detection reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For D-Xylose the moisture limit is ≤0.5%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. D-Xylose can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: D-Xylose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for D-Xylose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is D-Xylose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which D-Xylose grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/d-xylose/grades/ Reviewed: 2026-11-20 D-Xylose is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. D-Xylose is no exception: D-Xylose 99% and D-Xylose fine powder can share an assay and still behave differently in the line. ## The grade map D-Xylose grades | | Grade | Best fit | What changes | D-Xylose 99% | Flavour and food systems | Standard grade | D-Xylose fine powder | Dry blends | Faster dispersion | D-Xylose granular | Tabletop and sachets | Better flow ## Sweetness and taste The indicative sweetness is 40–50% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with a slight woody or cereal note at higher doses; used as a flavour precursor as well as a sweetener. The use level is 0.5–5% in flavour and food systems, depending on the function. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; clean solutions at use levels. Moderate; store sealed and dry. ## The grade decision The level-four page for this product compares D-Xylose with Xylitol. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. D-Xylose vs xylitol: a sugar and a polyol are not interchangeable D-Xylose is a reducing sugar used for flavour and browning; xylitol is a polyol used as a bulk sweetener. They share a name root, not a function. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: D-Xylose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for D-Xylose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is D-Xylose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 D-Xylose stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/d-xylose/stability/ Reviewed: 2026-11-20 D-Xylose is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderate; store sealed and dry. The specification limits moisture to ≤0.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Participates in browning and flavour generation at high heat. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does D-Xylose is added at 0.5–5% in flavour and food systems, depending on the function. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; clean solutions at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: D-Xylose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for D-Xylose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is D-Xylose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 D-Xylose: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/d-xylose/moq/ Reviewed: 2026-11-20 D-Xylose is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: D-Xylose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for D-Xylose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is D-Xylose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove D-Xylose is what the specification says URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/d-xylose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. D-Xylose can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. D-Xylose needs both. ## Why identity is a separate test The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI retention time against a D-xylose standard - Other sugars by HPLC - Optical rotation - IR spectrum For this grade, the primary assay is HPLC-RI or HPLC with refractive index detection. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - D-Glucose or D-xylose syrup solids blended into the crystal - A lower-assay grade - Carrier not declared - L-Arabinose substituted without a label change None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For D-Xylose, the relevant identity format is D-Xylose 98.0–101.0%, other sugars ≤1.0%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: D-Xylose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for D-Xylose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is D-Xylose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 D-Xylose vs xylitol: a sugar and a polyol are not interchangeable URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/d-xylose/grades/d-xylose-vs-xylitol/ Reviewed: 2026-11-20 Two grades, one application decision is a formulation question, not a catalogue question. D-Xylose is a reducing sugar used for flavour and browning; xylitol is a polyol used as a bulk sweetener. They share a name root, not a function. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineD-Xylose is a reducing sugar used for flavour and browning; xylitol is a polyol used as a bulk sweetener. They share a name root, not a function. ## The two options D-Xylose vs xylitol: a sugar and a polyol are not interchangeable | | Option | What it is | Option A | D-Xylose: a reducing pentose, ~40–50% sweetness, participates in browning and flavour generation. | Option B | Xylitol: a pentitol, ~90–100% sweetness, strong cooling, used as a sugar-free bulk sweetener. ## Taste and sweetness The published sweetness for D-Xylose is 40–50% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with a slight woody or cereal note at higher doses; used as a flavour precursor as well as a sweetener. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process D-Xylose: a reducing pentose, ~40–50% sweetness, participates in browning and flavour generation. Xylitol: a pentitol, ~90–100% sweetness, strong cooling, used as a sugar-free bulk sweetener. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; clean solutions at use levels. Participates in browning and flavour generation at high heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are D-Xylose 99%, D-Xylose fine powder, D-Xylose granular. The primary specification is 98.0–101.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; clean solutions at use levels. 0.5–5% in flavour and food systems, depending on the function is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose xylitol when the job is sugar-free sweetness and bulk. Choose D-xylose when the job is a flavour precursor, a browning reaction or a specialty food system. Do not swap one for the other on price; the finished product will change. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: D-Xylose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for D-Xylose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is D-Xylose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Isomaltulose: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/isomaltulose/coa/ Reviewed: 2026-11-20 Isomaltulose (CAS 13718-94-0) is a rare sugar. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineIsomaltulose is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Isomaltulose | | Parameter | Specification | Isomaltulose (dry basis) | ≥98.0% (HPLC-RI) | Appearance | White crystalline powder | Moisture | ≤0.5% | pH (10% solution) | 4.5–7.0 | Solubility | Soluble in water; low hygroscopicity | Particle size | ≥95% through 60 mesh | Bulk density | 0.55–0.85 g/mL | Other sugars | ≤1.0% (HPLC-RI) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Isomaltulose the identity evidence used for release is: - HPLC-RI assay against a Isomaltulose standard - Other-sugar profile by the same method - Optical rotation and IR spectrum - Moisture and hydrate or anomer form HPLC-RI assay against a Isomaltulose standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Isomaltulose the moisture limit is ≤0.5%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Isomaltulose can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Isomaltulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Isomaltulose grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/isomaltulose/grades/ Reviewed: 2026-11-20 Isomaltulose is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Isomaltulose is no exception: Isomaltulose crystalline and Isomaltulose granular can share an assay and still behave differently in the line. ## The grade map Isomaltulose grades | | Grade | Best fit | What changes | Isomaltulose crystalline | Beverages and bakery | Standard grade | Isomaltulose granular | Tabletop and dry mixes | Better flow | Isomaltulose fine powder | Dry blends | Faster dispersion ## Sweetness and taste The indicative sweetness is 40–50% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, sucrose-like sweetness with no strong cooling; the body is closer to sugar than a high-intensity sweetener. The use level is 5–30% in beverages, bakery and confectionery, depending on the sugar replacement. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; low hygroscopicity and a clean solution. Low; easier to store than fructose or sorbitol. ## The grade decision The level-four page for this product compares Isomaltulose with Isomaltulose granular. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Isomaltulose vs sucrose: bulk and sweetness are different Isomaltulose is about half as sweet as sucrose, so replacing sucrose one-for-one changes both the sweetness and the bulk. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Isomaltulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Isomaltulose stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/isomaltulose/stability/ Reviewed: 2026-11-20 Isomaltulose is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low; easier to store than fructose or sorbitol. The specification limits moisture to ≤0.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; it can participate in browning at high heat. Stable across normal food pH; acidic hydrolysis should be checked. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Isomaltulose is added at 5–30% in beverages, bakery and confectionery, depending on the sugar replacement. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; low hygroscopicity and a clean solution. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Isomaltulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Isomaltulose: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/isomaltulose/moq/ Reviewed: 2026-11-20 Isomaltulose is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Isomaltulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Isomaltulose is what the specification says URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/isomaltulose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Isomaltulose can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Isomaltulose needs both. ## Why identity is a separate test The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI assay against a Isomaltulose standard - Other-sugar profile by the same method - Optical rotation and IR spectrum - Moisture and hydrate or anomer form For this grade, the primary assay is HPLC-RI. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Sucrose, dextrose or fructose blended into Isomaltulose - A lower-assay grade or a different hydrate - A rare-sugar blend presented as a single sugar - Carrier or bulking agent not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Isomaltulose, the relevant identity format is Isomaltulose ≥98%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Isomaltulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Isomaltulose vs sucrose: bulk and sweetness are different URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/isomaltulose/grades/isomaltulose-vs-sucrose/ Reviewed: 2026-11-20 A functional sugar, not a high-intensity sweetener is a formulation question, not a catalogue question. Isomaltulose is about half as sweet as sucrose, so replacing sucrose one-for-one changes both the sweetness and the bulk. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineIsomaltulose is about half as sweet as sucrose, so replacing sucrose one-for-one changes both the sweetness and the bulk. ## The two options Isomaltulose vs sucrose: bulk and sweetness are different | | Option | What it is | Option A | Isomaltulose: sucrose-like body, lower sweetness, low hygroscopicity, a different metabolic profile. | Option B | Isomaltulose granular: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Isomaltulose is 40–50% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, sucrose-like sweetness with no strong cooling; the body is closer to sugar than a high-intensity sweetener. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Isomaltulose: sucrose-like body, lower sweetness, low hygroscopicity, a different metabolic profile. Isomaltulose granular: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; low hygroscopicity and a clean solution. Stable in dry form; it can participate in browning at high heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Isomaltulose crystalline, Isomaltulose granular, Isomaltulose fine powder. The primary specification is ≥98.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; low hygroscopicity and a clean solution. 5–30% in beverages, bakery and confectionery, depending on the sugar replacement is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use isomaltulose when the product needs sugar-like bulk and a lower sweetness, and the market accepts the ingredient. Top up the sweetness with a high-intensity sweetener if needed, and test the browning in the real bake. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Isomaltulose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltulose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltulose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Crystalline Fructose: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/crystalline-fructose/coa/ Reviewed: 2026-11-20 Crystalline Fructose (CAS 57-48-7) is a rare sugar. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineCrystalline Fructose is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Crystalline Fructose | | Parameter | Specification | Fructose (dry basis) | ≥99.5% (HPLC-RI) | Appearance | White crystalline powder | Moisture | ≤0.5% | pH (10% solution) | 4.0–6.5 | Solubility | Freely soluble in water | Particle size | ≥95% through 60 mesh | Bulk density | 0.55–0.85 g/mL | Other sugars | ≤0.5% (HPLC-RI) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Crystalline Fructose the identity evidence used for release is: - HPLC-RI assay against a Crystalline Fructose standard - Other-sugar profile by the same method - Optical rotation and IR spectrum - Moisture and hydrate or anomer form HPLC-RI assay against a Crystalline Fructose standard is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Crystalline Fructose the moisture limit is ≤0.5%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Crystalline Fructose can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Crystalline Fructose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Crystalline Fructose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Crystalline Fructose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Crystalline Fructose grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/crystalline-fructose/grades/ Reviewed: 2026-11-20 Crystalline Fructose is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Crystalline Fructose is no exception: Crystalline fructose and Fructose fine powder can share an assay and still behave differently in the line. ## The grade map Crystalline Fructose grades | | Grade | Best fit | What changes | Crystalline fructose | Beverages and bakery | Standard grade | Fructose fine powder | Dry blends | Faster dispersion | Fructose granular | Tabletop and dry mixes | Better flow ## Sweetness and taste The indicative sweetness is 130–180% of sucrose at equal solids, depending on the matrix. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, fast-onset sweetness with a strong body; at high dose it can taste syrupy. The use level is 2–15% in beverages, bakery and confectionery, depending on the sugar replacement. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; hygroscopic and humectant. Hygroscopic; store sealed below 25 °C and 60% RH. ## The grade decision The level-four page for this product compares Crystalline fructose with Fructose fine powder. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Which Crystalline Fructose grade fits the brief? Fructose is sweeter than sucrose and browns more readily, but it is still a sugar. It is not a zero-calorie or sugar-free ingredient. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Crystalline Fructose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Crystalline Fructose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Crystalline Fructose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Crystalline Fructose stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/crystalline-fructose/stability/ Reviewed: 2026-11-20 Crystalline Fructose is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C and 60% RH. The specification limits moisture to ≤0.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Browns readily at high heat; useful in bakery and a consideration in clear beverages. Stable across normal food pH; colour should be checked at high heat. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Crystalline Fructose is added at 2–15% in beverages, bakery and confectionery, depending on the sugar replacement. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; hygroscopic and humectant. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Crystalline Fructose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Crystalline Fructose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Crystalline Fructose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Crystalline Fructose: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/crystalline-fructose/moq/ Reviewed: 2026-11-20 Crystalline Fructose is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Crystalline Fructose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Crystalline Fructose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Crystalline Fructose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Crystalline Fructose is what the specification says URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/crystalline-fructose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Crystalline Fructose can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Crystalline Fructose needs both. ## Why identity is a separate test The active is a specific sugar isomer, so the assay and the other-sugar profile are the identity test as much as the purity test. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI assay against a Crystalline Fructose standard - Other-sugar profile by the same method - Optical rotation and IR spectrum - Moisture and hydrate or anomer form For this grade, the primary assay is HPLC-RI. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Sucrose, dextrose or fructose blended into Crystalline Fructose - A lower-assay grade or a different hydrate - A rare-sugar blend presented as a single sugar - Carrier or bulking agent not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Crystalline Fructose, the relevant identity format is Fructose ≥99.5%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Crystalline Fructose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Crystalline Fructose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Crystalline Fructose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Which Crystalline Fructose grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/rare-sugars/crystalline-fructose/grades/crystalline-fructose-vs-sucrose/ Reviewed: 2026-11-20 A different sugar, not a low-calorie swap is a formulation question, not a catalogue question. Fructose is sweeter than sucrose and browns more readily, but it is still a sugar. It is not a zero-calorie or sugar-free ingredient. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineFructose is sweeter than sucrose and browns more readily, but it is still a sugar. It is not a zero-calorie or sugar-free ingredient. ## The two options Which Crystalline Fructose grade fits the brief? | | Option | What it is | Option A | Crystalline fructose: the standard catalog grade. | Option B | Fructose fine powder: the alternative grade for a different process. ## Taste and sweetness The published sweetness for Crystalline Fructose is 130–180% of sucrose at equal solids, depending on the matrix. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, fast-onset sweetness with a strong body; at high dose it can taste syrupy. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Crystalline fructose: the standard catalog grade. Fructose fine powder: the alternative grade for a different process. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; hygroscopic and humectant. Browns readily at high heat; useful in bakery and a consideration in clear beverages. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Crystalline fructose, Fructose fine powder, Fructose granular. The primary specification is ≥99.5% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; hygroscopic and humectant. 2–15% in beverages, bakery and confectionery, depending on the sugar replacement is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use fructose where its sweetness, humectancy or browning is the technical reason, and declare it as a sugar. Do not present it as a sugar-free or low-calorie sweetener. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Crystalline Fructose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Crystalline Fructose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Crystalline Fructose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Inulin: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/inulin/coa/ Reviewed: 2026-11-20 Inulin (CAS 9005-80-5) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineInulin is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI and AOAC enzymatic fibre method. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Inulin | | Parameter | Specification | Inulin (dry basis) | ≥90.0% (HPLC-RI) | Dietary fibre | ≥90.0% (AOAC 997.08 or equivalent) | Degree of polymerisation | DP 2–60, average 10–12 | Appearance | White to off-white powder | Moisture | ≤5.0% | pH (10% solution) | 4.5–7.0 | Solubility | Soluble in water; viscosity depends on chain length | Particle size | ≥95% through 80 mesh | Bulk density | 0.40–0.70 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Inulin the identity evidence used for release is: - HPLC-RI sugar and fructan profile - Dietary fibre by an AOAC enzymatic method - Degree of polymerisation - Moisture and ash HPLC-RI sugar and fructan profile is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI and AOAC enzymatic fibre method reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Inulin the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Inulin can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Inulin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Inulin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Inulin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Inulin grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/inulin/grades/ Reviewed: 2026-11-20 Inulin is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Inulin is no exception: Inulin powder and Inulin granulated can share an assay and still behave differently in the line. ## The grade map Inulin grades | | Grade | Best fit | What changes | Inulin powder | Beverages, dairy, bakery | Standard chain length | Inulin granulated | Dry blends and tabletop | Better flow | Inulin high-DP | Viscosity and body | Longer chains, different texture | Organic inulin | Organic-certified products | Certificate and traceability required ## Sweetness and taste The indicative sweetness is 10% of sucrose, indicative for standard inulin; higher for oligofructose. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with a clean, slightly creamy body; at high dose it can add a faint vegetal note. The use level is 2–10% in beverages, dairy and bakery, depending on the fibre target and the texture. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; longer-chain inulin builds viscosity and shorter chains are more soluble and sweeter. Moderately hygroscopic; store sealed below 25 °C and 65% RH. ## The grade decision The level-four page for this product compares Inulin with Oligofructose. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Inulin vs oligofructose: chain length changes the job Inulin is a longer-chain fructan used for body and fibre; oligofructose is the shorter-chain fraction, sweeter and more soluble. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Inulin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Inulin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Inulin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Inulin stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/inulin/stability/ Reviewed: 2026-11-20 Inulin is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Moderately hygroscopic; store sealed below 25 °C and 65% RH. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; in acidic solution, hydrolysis increases with heat and time. Most stable at pH 5–7; at pH below 4 and high temperature, chain length falls. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Inulin is added at 2–10% in beverages, dairy and bakery, depending on the fibre target and the texture. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; longer-chain inulin builds viscosity and shorter chains are more soluble and sweeter. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Inulin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Inulin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Inulin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Inulin: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/inulin/moq/ Reviewed: 2026-11-20 Inulin is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Inulin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Inulin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Inulin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Inulin is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/inulin/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Inulin can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Inulin needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and fructan profile - Dietary fibre by an AOAC enzymatic method - Degree of polymerisation - Moisture and ash For this grade, the primary assay is HPLC-RI and AOAC enzymatic fibre method. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, dextrose or sucrose blended into inulin - A lower-fibre grade sold as 90% - Oligofructose presented as standard inulin - A different botanical source not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Inulin, the relevant identity format is Inulin ≥90%, fibre ≥90%, DP 2–60. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Inulin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Inulin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Inulin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Inulin vs oligofructose: chain length changes the job URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/inulin/grades/inulin-powder-vs-oligofructose/ Reviewed: 2026-11-20 One fibre family, two textures is a formulation question, not a catalogue question. Inulin is a longer-chain fructan used for body and fibre; oligofructose is the shorter-chain fraction, sweeter and more soluble. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineInulin is a longer-chain fructan used for body and fibre; oligofructose is the shorter-chain fraction, sweeter and more soluble. ## The two options Inulin vs oligofructose: chain length changes the job | | Option | What it is | Option A | Inulin: DP 2–60, viscosity and body, mild sweetness, useful in dairy and bakery. | Option B | Oligofructose: DP 2–8, more soluble, sweeter, less viscosity, useful in beverages and sugar replacement. ## Taste and sweetness The published sweetness for Inulin is 10% of sucrose, indicative for standard inulin; higher for oligofructose. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with a clean, slightly creamy body; at high dose it can add a faint vegetal note. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Inulin: DP 2–60, viscosity and body, mild sweetness, useful in dairy and bakery. Oligofructose: DP 2–8, more soluble, sweeter, less viscosity, useful in beverages and sugar replacement. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; longer-chain inulin builds viscosity and shorter chains are more soluble and sweeter. Stable in dry form; in acidic solution, hydrolysis increases with heat and time. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Inulin powder, Inulin granulated, Inulin high-DP, Organic inulin. The primary specification is ≥90.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; longer-chain inulin builds viscosity and shorter chains are more soluble and sweeter. 2–10% in beverages, dairy and bakery, depending on the fibre target and the texture is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose inulin when the formula needs body and fibre without much sweetness. Choose oligofructose when the formula needs a clean, sweet, soluble fibre and the viscosity must stay low. Check the fibre method on both grades. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Inulin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Inulin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Inulin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Fructooligosaccharides (FOS): what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/fructooligosaccharides/coa/ Reviewed: 2026-11-20 Fructooligosaccharides (FOS) (CAS 308066-66-2) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineFructooligosaccharides (FOS) is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI and AOAC enzymatic fibre method. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Fructooligosaccharides (FOS) | | Parameter | Specification | FOS (dry basis) | ≥95.0% (HPLC-RI) | Dietary fibre | ≥95.0% (AOAC 997.08 or equivalent) | Degree of polymerisation | DP 2–8 | Appearance | White to off-white powder | Moisture | ≤5.0% | pH (10% solution) | 4.5–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Bulk density | 0.40–0.70 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Fructooligosaccharides (FOS) the identity evidence used for release is: - HPLC-RI FOS and sugar profile - Dietary fibre by an AOAC enzymatic method - Degree of polymerisation - Moisture and ash HPLC-RI FOS and sugar profile is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI and AOAC enzymatic fibre method reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Fructooligosaccharides (FOS) the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Fructooligosaccharides (FOS) can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Fructooligosaccharides (FOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Fructooligosaccharides (FOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Fructooligosaccharides (FOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Fructooligosaccharides (FOS) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/fructooligosaccharides/grades/ Reviewed: 2026-11-20 Fructooligosaccharides (FOS) is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Fructooligosaccharides (FOS) is no exception: FOS powder 95% and FOS liquid 75% can share an assay and still behave differently in the line. ## The grade map Fructooligosaccharides (FOS) grades | | Grade | Best fit | What changes | FOS powder 95% | Beverages, dairy, supplements | Standard grade | FOS liquid 75% | Syrup and beverage lines | Water and solids must be specified | FOS 90% | Cost-sensitive food use | Higher sugar fraction | Organic FOS | Organic-certified products | Certificate and traceability required ## Sweetness and taste The indicative sweetness is 30–50% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, mild sweetness with a slight fruity note; less body than inulin and easier in a clear beverage. The use level is 2–8% in beverages and dairy, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; low viscosity at use levels. Hygroscopic; store sealed below 25 °C. ## The grade decision The level-four page for this product compares Powder with 75% syrup. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. FOS powder vs 75% syrup: water, sweetness and handling A 75% FOS syrup contributes 25% water and a different sweetness per kilogram; the powder is the dry-blend form. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Fructooligosaccharides (FOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Fructooligosaccharides (FOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Fructooligosaccharides (FOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Fructooligosaccharides (FOS) stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/fructooligosaccharides/stability/ Reviewed: 2026-11-20 Fructooligosaccharides (FOS) is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; hydrolysis increases at low pH and high temperature. Most stable at pH 5–7; acidic beverages need a shelf-life check. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Fructooligosaccharides (FOS) is added at 2–8% in beverages and dairy, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; low viscosity at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Fructooligosaccharides (FOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Fructooligosaccharides (FOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Fructooligosaccharides (FOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Fructooligosaccharides (FOS): MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/fructooligosaccharides/moq/ Reviewed: 2026-11-20 Fructooligosaccharides (FOS) is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Fructooligosaccharides (FOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Fructooligosaccharides (FOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Fructooligosaccharides (FOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Fructooligosaccharides (FOS) is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/fructooligosaccharides/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Fructooligosaccharides (FOS) can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Fructooligosaccharides (FOS) needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI FOS and sugar profile - Dietary fibre by an AOAC enzymatic method - Degree of polymerisation - Moisture and ash For this grade, the primary assay is HPLC-RI and AOAC enzymatic fibre method. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Sucrose, dextrose or maltodextrin used as a bulking agent - A lower-FOS grade sold as 95% - Inulin presented as FOS - A different botanical or enzymatic source not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Fructooligosaccharides (FOS), the relevant identity format is FOS ≥95%, DP 2–8, fibre ≥95%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Fructooligosaccharides (FOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Fructooligosaccharides (FOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Fructooligosaccharides (FOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 FOS powder vs 75% syrup: water, sweetness and handling URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/fructooligosaccharides/grades/fos-powder-vs-liquid/ Reviewed: 2026-11-20 Two forms, two solids calculations is a formulation question, not a catalogue question. A 75% FOS syrup contributes 25% water and a different sweetness per kilogram; the powder is the dry-blend form. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 75% FOS syrup contributes 25% water and a different sweetness per kilogram; the powder is the dry-blend form. ## The two options FOS powder vs 75% syrup: water, sweetness and handling | | Option | What it is | Option A | Powder: 95% FOS, easy to weigh, hygroscopic, good for dry blends and supplements. | Option B | 75% syrup: easier to pump and disperse, lower solids, water activity and preservation implications. ## Taste and sweetness The published sweetness for Fructooligosaccharides (FOS) is 30–50% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, mild sweetness with a slight fruity note; less body than inulin and easier in a clear beverage. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Powder: 95% FOS, easy to weigh, hygroscopic, good for dry blends and supplements. 75% syrup: easier to pump and disperse, lower solids, water activity and preservation implications. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; low viscosity at use levels. Stable in dry form; hydrolysis increases at low pH and high temperature. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are FOS powder 95%, FOS liquid 75%, FOS 90%, Organic FOS. The primary specification is ≥95.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; low viscosity at use levels. 2–8% in beverages and dairy, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use powder for a dry blend, a capsule or a supplement where moisture is critical. Use the syrup when the line is liquid and the water is already in the batch sheet; re-check the solids and the preservation. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Fructooligosaccharides (FOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Fructooligosaccharides (FOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Fructooligosaccharides (FOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Galactooligosaccharides (GOS): what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/galactooligosaccharides/coa/ Reviewed: 2026-11-20 Galactooligosaccharides (GOS) (CAS 6587-31-1) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineGalactooligosaccharides (GOS) is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI and AOAC enzymatic fibre method. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Galactooligosaccharides (GOS) | | Parameter | Specification | GOS (dry basis) | ≥70.0% (HPLC-RI) | Dietary fibre | ≥70.0% (AOAC 2009.01 or equivalent) | Degree of polymerisation | DP 2–8 | Lactose | ≤10.0% (HPLC-RI) | Appearance | Colourless to light yellow syrup or white powder | Moisture | ≤5.0% (powder); 25% solids in syrup | pH (10% solution) | 4.0–7.0 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh (powder) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Galactooligosaccharides (GOS) the identity evidence used for release is: - HPLC-RI GOS and lactose profile - Dietary fibre by an AOAC enzymatic method - Degree of polymerisation - Moisture and ash HPLC-RI GOS and lactose profile is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI and AOAC enzymatic fibre method reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Galactooligosaccharides (GOS) the moisture limit is ≤5.0% (powder); 25% solids in syrup. The particle size is ≥95% through 80 mesh (powder). Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Galactooligosaccharides (GOS) can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Galactooligosaccharides (GOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Galactooligosaccharides (GOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Galactooligosaccharides (GOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Galactooligosaccharides (GOS) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/galactooligosaccharides/grades/ Reviewed: 2026-11-20 Galactooligosaccharides (GOS) is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Galactooligosaccharides (GOS) is no exception: GOS syrup 75% and GOS powder 70% can share an assay and still behave differently in the line. ## The grade map Galactooligosaccharides (GOS) grades | | Grade | Best fit | What changes | GOS syrup 75% | Beverages and dairy | Low viscosity, clean taste | GOS powder 70% | Dry blends and supplements | Higher solids, hygroscopic | GOS 90% powder | High-fibre concentrates | Lower lactose, higher cost | Organic GOS | Organic-certified products | Certificate and traceability required ## Sweetness and taste The indicative sweetness is 20–30% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild, clean sweetness with a slightly milky note; useful in dairy and beverage systems. The use level is 2–8% in beverages and dairy, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; low viscosity and a clean solution at use levels. Hygroscopic; store sealed and cool. ## The grade decision The level-four page for this product compares Syrup 75% with Powder 70%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. GOS syrup vs powder: the water and the lactose GOS syrup carries water and residual lactose; the powder is easier in a dry blend but more hygroscopic. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Galactooligosaccharides (GOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Galactooligosaccharides (GOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Galactooligosaccharides (GOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Galactooligosaccharides (GOS) stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/galactooligosaccharides/stability/ Reviewed: 2026-11-20 Galactooligosaccharides (GOS) is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed and cool. The specification limits moisture to ≤5.0% (powder); 25% solids in syrup. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal beverage processing; acidic hydrolysis should be checked. Most stable at pH 4–7; very low pH and high heat increase hydrolysis. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Galactooligosaccharides (GOS) is added at 2–8% in beverages and dairy, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; low viscosity and a clean solution at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum and 250 kg drum for syrup are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Galactooligosaccharides (GOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Galactooligosaccharides (GOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Galactooligosaccharides (GOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Galactooligosaccharides (GOS): MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/galactooligosaccharides/moq/ Reviewed: 2026-11-20 Galactooligosaccharides (GOS) is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum or 250 kg drum for syrup, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Galactooligosaccharides (GOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Galactooligosaccharides (GOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Galactooligosaccharides (GOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Galactooligosaccharides (GOS) is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/galactooligosaccharides/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Galactooligosaccharides (GOS) can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Galactooligosaccharides (GOS) needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI GOS and lactose profile - Dietary fibre by an AOAC enzymatic method - Degree of polymerisation - Moisture and ash For this grade, the primary assay is HPLC-RI and AOAC enzymatic fibre method. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Lactose, dextrose or maltodextrin used as a bulking agent - A lower-GOS syrup sold as 70% - FOS presented as GOS - A non-dairy GOS not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Galactooligosaccharides (GOS), the relevant identity format is GOS ≥70%, DP 2–8, lactose ≤10%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Galactooligosaccharides (GOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Galactooligosaccharides (GOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Galactooligosaccharides (GOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 GOS syrup vs powder: the water and the lactose URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/galactooligosaccharides/grades/gos-syrup-vs-powder/ Reviewed: 2026-11-20 A dairy-derived fibre needs a declaration check is a formulation question, not a catalogue question. GOS syrup carries water and residual lactose; the powder is easier in a dry blend but more hygroscopic. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineGOS syrup carries water and residual lactose; the powder is easier in a dry blend but more hygroscopic. ## The two options GOS syrup vs powder: the water and the lactose | | Option | What it is | Option A | Syrup 75%: low viscosity, easy to pump, water and lactose already in the batch. | Option B | Powder 70%: easier for a dry blend and a capsule, but hygroscopic and higher cost per kilogram of solids. ## Taste and sweetness The published sweetness for Galactooligosaccharides (GOS) is 20–30% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild, clean sweetness with a slightly milky note; useful in dairy and beverage systems. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Syrup 75%: low viscosity, easy to pump, water and lactose already in the batch. Powder 70%: easier for a dry blend and a capsule, but hygroscopic and higher cost per kilogram of solids. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; low viscosity and a clean solution at use levels. Stable in dry form and through normal beverage processing; acidic hydrolysis should be checked. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are GOS syrup 75%, GOS powder 70%, GOS 90% powder, Organic GOS. The primary specification is ≥70.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; low viscosity and a clean solution at use levels. 2–8% in beverages and dairy, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the syrup for a beverage or dairy line where the water is accounted for and the lactose declaration is already understood. Choose the powder for a supplement or dry mix where the moisture is critical. Check the lactose figure in both cases. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Galactooligosaccharides (GOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Galactooligosaccharides (GOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Galactooligosaccharides (GOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Xylooligosaccharides (XOS): what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/xylooligosaccharides/coa/ Reviewed: 2026-11-20 Xylooligosaccharides (XOS) (CAS —) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineXylooligosaccharides (XOS) is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI and AOAC enzymatic fibre method. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Xylooligosaccharides (XOS) | | Parameter | Specification | XOS (dry basis) | ≥95.0% (HPLC-RI) | Dietary fibre | ≥85.0% (AOAC 2009.01 or equivalent) | Degree of polymerisation | DP 2–7 | Appearance | White to light yellow powder | Moisture | ≤5.0% | pH (10% solution) | 3.5–6.5 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Ash | ≤0.5% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Xylooligosaccharides (XOS) the identity evidence used for release is: - HPLC-RI XOS and sugar profile - Dietary fibre by an AOAC enzymatic method - Degree of polymerisation - Ash and moisture HPLC-RI XOS and sugar profile is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI and AOAC enzymatic fibre method reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Xylooligosaccharides (XOS) the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Xylooligosaccharides (XOS) can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Xylooligosaccharides (XOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylooligosaccharides (XOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylooligosaccharides (XOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Xylooligosaccharides (XOS) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/xylooligosaccharides/grades/ Reviewed: 2026-11-20 Xylooligosaccharides (XOS) is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Xylooligosaccharides (XOS) is no exception: XOS powder 95% and XOS liquid 70% can share an assay and still behave differently in the line. ## The grade map Xylooligosaccharides (XOS) grades | | Grade | Best fit | What changes | XOS powder 95% | Beverages and supplements | Standard grade | XOS liquid 70% | Syrup lines | Water and solids must be specified | XOS 90% | Cost-sensitive food use | Higher sugar fraction | XOS 99% | High-purity supplements | Lower ash and sugar, higher cost ## Sweetness and taste The indicative sweetness is 20–30% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild, clean sweetness with a slight woody note at high dose; low viscosity makes it easy in beverages. The use level is 1–5% in beverages and supplements, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; low viscosity and a clean solution. Hygroscopic; store sealed below 25 °C. ## The grade decision The level-four page for this product compares Powder with Liquid 70%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. XOS powder vs liquid: low viscosity in two forms XOS is soluble and low-viscosity in both forms. The difference is the water, the solids and the preservation. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Xylooligosaccharides (XOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylooligosaccharides (XOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylooligosaccharides (XOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Xylooligosaccharides (XOS) stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/xylooligosaccharides/stability/ Reviewed: 2026-11-20 Xylooligosaccharides (XOS) is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; acidic hydrolysis should be checked at low pH and high heat. Most stable at pH 4–7; very low pH increases hydrolysis. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Xylooligosaccharides (XOS) is added at 1–5% in beverages and supplements, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; low viscosity and a clean solution. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Xylooligosaccharides (XOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylooligosaccharides (XOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylooligosaccharides (XOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Xylooligosaccharides (XOS): MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/xylooligosaccharides/moq/ Reviewed: 2026-11-20 Xylooligosaccharides (XOS) is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Xylooligosaccharides (XOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylooligosaccharides (XOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylooligosaccharides (XOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Xylooligosaccharides (XOS) is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/xylooligosaccharides/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Xylooligosaccharides (XOS) can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Xylooligosaccharides (XOS) needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI XOS and sugar profile - Dietary fibre by an AOAC enzymatic method - Degree of polymerisation - Ash and moisture For this grade, the primary assay is HPLC-RI and AOAC enzymatic fibre method. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Xylose, dextrose or maltodextrin used as a bulking agent - A lower-XOS grade sold as 95% - FOS presented as XOS - A different hemicellulose source not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Xylooligosaccharides (XOS), the relevant identity format is XOS ≥95%, DP 2–7, fibre ≥85%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Xylooligosaccharides (XOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylooligosaccharides (XOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylooligosaccharides (XOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 XOS powder vs liquid: low viscosity in two forms URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/xylooligosaccharides/grades/xos-powder-vs-liquid/ Reviewed: 2026-11-20 The fibre is easy either way; the water is not is a formulation question, not a catalogue question. XOS is soluble and low-viscosity in both forms. The difference is the water, the solids and the preservation. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineXOS is soluble and low-viscosity in both forms. The difference is the water, the solids and the preservation. ## The two options XOS powder vs liquid: low viscosity in two forms | | Option | What it is | Option A | Powder: 95% XOS, easy to weigh, hygroscopic, good for a dry blend or a capsule. | Option B | Liquid 70%: easy to pump, lower solids, water activity and preservation implications. ## Taste and sweetness The published sweetness for Xylooligosaccharides (XOS) is 20–30% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild, clean sweetness with a slight woody note at high dose; low viscosity makes it easy in beverages. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Powder: 95% XOS, easy to weigh, hygroscopic, good for a dry blend or a capsule. Liquid 70%: easy to pump, lower solids, water activity and preservation implications. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; low viscosity and a clean solution. Stable in dry form; acidic hydrolysis should be checked at low pH and high heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are XOS powder 95%, XOS liquid 70%, XOS 90%, XOS 99%. The primary specification is ≥95.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; low viscosity and a clean solution. 1–5% in beverages and supplements, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the powder when the formula is dry and the moisture is controlled. Choose the liquid when the line is already liquid and the water is in the batch sheet. Recalculate the fibre dose per kilogram of the form supplied. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Xylooligosaccharides (XOS) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Xylooligosaccharides (XOS). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Xylooligosaccharides (XOS): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Polydextrose: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/polydextrose/coa/ Reviewed: 2026-11-20 Polydextrose (CAS 68424-04-4) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one linePolydextrose is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI and AOAC enzymatic fibre method. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Polydextrose | | Parameter | Specification | Polydextrose (dry basis) | ≥90.0% (HPLC-RI) | Dietary fibre | ≥90.0% (AOAC 2009.01 or equivalent) | Appearance | White to cream-coloured powder | Moisture | ≤3.0% | pH (10% solution) | 3.0–6.0 | Solubility | Freely soluble in water; low viscosity | Particle size | ≥95% through 80 mesh | Bulk density | 0.40–0.70 g/mL | Glucose | ≤4.0% (HPLC-RI) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Polydextrose the identity evidence used for release is: - HPLC-RI polydextrose and glucose content - Dietary fibre by an AOAC enzymatic method - Moisture and ash - Solution clarity and colour HPLC-RI polydextrose and glucose content is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI and AOAC enzymatic fibre method reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Polydextrose the moisture limit is ≤3.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Polydextrose can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Polydextrose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Polydextrose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Polydextrose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Polydextrose grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/polydextrose/grades/ Reviewed: 2026-11-20 Polydextrose is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Polydextrose is no exception: Polydextrose powder and Polydextrose granular can share an assay and still behave differently in the line. ## The grade map Polydextrose grades | | Grade | Best fit | What changes | Polydextrose powder | Bakery, confectionery, beverages | Standard grade | Polydextrose granular | Dry blends | Better flow | Polydextrose syrup 70% | Beverage and syrup lines | Water and solids must be specified | Polydextrose fine powder | Fine dry blends | Faster dispersion ## Sweetness and taste The indicative sweetness is Very low, essentially non-sweet; used for bulk and body. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Almost no sweetness, with a clean, slightly tart note; it adds body and humectancy rather than sweetness. The use level is 2–10% in bakery, confectionery and beverages, depending on the function. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; low viscosity and a clean, slightly tart taste. Hygroscopic; store sealed and dry. ## The grade decision The level-four page for this product compares Powder with 70% syrup. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Polydextrose powder vs syrup: bulk without sweetness Polydextrose is almost non-sweet. It is chosen to replace the bulk and humectancy of sugar, not its taste. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Polydextrose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Polydextrose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Polydextrose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Polydextrose stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/polydextrose/stability/ Reviewed: 2026-11-20 Polydextrose is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed and dry. The specification limits moisture to ≤3.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal baking; browning is limited. Stable across normal food pH; the solution is mildly acidic. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Polydextrose is added at 2–10% in bakery, confectionery and beverages, depending on the function. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; low viscosity and a clean, slightly tart taste. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Polydextrose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Polydextrose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Polydextrose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Polydextrose: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/polydextrose/moq/ Reviewed: 2026-11-20 Polydextrose is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Polydextrose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Polydextrose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Polydextrose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Polydextrose is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/polydextrose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Polydextrose can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Polydextrose needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI polydextrose and glucose content - Dietary fibre by an AOAC enzymatic method - Moisture and ash - Solution clarity and colour For this grade, the primary assay is HPLC-RI and AOAC enzymatic fibre method. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-polydextrose grade sold as 90% - A syrup solid sold as powder - Carrier not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Polydextrose, the relevant identity format is Polydextrose ≥90%, fibre ≥90%, glucose ≤4%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Polydextrose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Polydextrose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Polydextrose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Polydextrose powder vs syrup: bulk without sweetness URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/polydextrose/grades/polydextrose-powder-vs-liquid/ Reviewed: 2026-11-20 The job is body, not sugar is a formulation question, not a catalogue question. Polydextrose is almost non-sweet. It is chosen to replace the bulk and humectancy of sugar, not its taste. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one linePolydextrose is almost non-sweet. It is chosen to replace the bulk and humectancy of sugar, not its taste. ## The two options Polydextrose powder vs syrup: bulk without sweetness | | Option | What it is | Option A | Powder: 90% polydextrose, easy to weigh, hygroscopic, good for bakery and dry blends. | Option B | 70% syrup: easy to pump, lower solids, water and preservation implications. ## Taste and sweetness The published sweetness for Polydextrose is Very low, essentially non-sweet; used for bulk and body. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Almost no sweetness, with a clean, slightly tart note; it adds body and humectancy rather than sweetness. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Powder: 90% polydextrose, easy to weigh, hygroscopic, good for bakery and dry blends. 70% syrup: easy to pump, lower solids, water and preservation implications. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; low viscosity and a clean, slightly tart taste. Stable in dry form and through normal baking; browning is limited. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Polydextrose powder, Polydextrose granular, Polydextrose syrup 70%, Polydextrose fine powder. The primary specification is ≥90.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; low viscosity and a clean, slightly tart taste. 2–10% in bakery, confectionery and beverages, depending on the function is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use powder when the formula needs dry bulk and the moisture is controlled. Use the syrup in a liquid system where the water is already part of the recipe. In both cases, add the sweetness separately with a polyol or a high-intensity sweetener. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Polydextrose specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Polydextrose. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Polydextrose: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Resistant Dextrin: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/resistant-dextrin/coa/ Reviewed: 2026-11-20 Resistant Dextrin (CAS —) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineResistant Dextrin is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is AOAC 2009.01 dietary fibre and HPLC-RI sugar profile. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Resistant Dextrin | | Parameter | Specification | Dietary fibre | ≥85.0% (AOAC 2009.01) | Resistant dextrin | ≥85.0% (HPLC-RI) | Appearance | White to light yellow powder | Moisture | ≤5.0% | pH (10% solution) | 3.0–6.0 | Solubility | Freely soluble in water; low viscosity | Particle size | ≥95% through 80 mesh | Bulk density | 0.40–0.70 g/mL | Glucose | ≤5.0% (HPLC-RI) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Resistant Dextrin the identity evidence used for release is: - Dietary fibre by AOAC 2009.01 - HPLC-RI sugar and dextrin profile - Moisture and ash - Solution clarity Dietary fibre by AOAC 2009.01 is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not AOAC 2009.01 dietary fibre and HPLC-RI sugar profile reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Resistant Dextrin the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Resistant Dextrin can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Resistant Dextrin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Resistant Dextrin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Resistant Dextrin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Resistant Dextrin grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/resistant-dextrin/grades/ Reviewed: 2026-11-20 Resistant Dextrin is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Resistant Dextrin is no exception: Resistant dextrin powder and Resistant dextrin syrup 70% can share an assay and still behave differently in the line. ## The grade map Resistant Dextrin grades | | Grade | Best fit | What changes | Resistant dextrin powder | Beverages, supplements, bakery | Standard grade | Resistant dextrin syrup 70% | Beverage lines | Water and solids must be specified | Resistant dextrin fine powder | Dry blends | Faster dispersion | Organic resistant dextrin | Organic-certified products | Certificate and traceability required ## Sweetness and taste The indicative sweetness is 10% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, almost neutral with a very mild sweetness; useful where the fibre should not change the flavour. The use level is 2–10% in beverages and supplements, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; low viscosity, clean solution. Hygroscopic; store sealed below 25 °C. ## The grade decision The level-four page for this product compares AOAC 2009.01 with AOAC 2011.25. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Resistant dextrin and the fibre method: why two numbers disagree AOAC 2009.01 and AOAC 2011.25 can return different fibre figures for the same resistant dextrin. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Resistant Dextrin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Resistant Dextrin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Resistant Dextrin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Resistant Dextrin stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/resistant-dextrin/stability/ Reviewed: 2026-11-20 Resistant Dextrin is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form and through normal beverage processing. Stable across normal food pH; acid hydrolysis is limited. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Resistant Dextrin is added at 2–10% in beverages and supplements, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; low viscosity, clean solution. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Resistant Dextrin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Resistant Dextrin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Resistant Dextrin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Resistant Dextrin: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/resistant-dextrin/moq/ Reviewed: 2026-11-20 Resistant Dextrin is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 1–7 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Resistant Dextrin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Resistant Dextrin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Resistant Dextrin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Resistant Dextrin is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/resistant-dextrin/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Resistant Dextrin can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Resistant Dextrin needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - Dietary fibre by AOAC 2009.01 - HPLC-RI sugar and dextrin profile - Moisture and ash - Solution clarity For this grade, the primary assay is AOAC 2009.01 dietary fibre and HPLC-RI sugar profile. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as 85% - A fibre method that overstates the result - Carrier not declared None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Resistant Dextrin, the relevant identity format is Dietary fibre ≥85%, resistant dextrin ≥85%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Resistant Dextrin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Resistant Dextrin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Resistant Dextrin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Resistant dextrin and the fibre method: why two numbers disagree URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/resistant-dextrin/grades/resistant-dextrin-fibre-methods/ Reviewed: 2026-11-20 The method is part of the specification is a formulation question, not a catalogue question. AOAC 2009.01 and AOAC 2011.25 can return different fibre figures for the same resistant dextrin. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineAOAC 2009.01 and AOAC 2011.25 can return different fibre figures for the same resistant dextrin. ## The two options Resistant dextrin and the fibre method: why two numbers disagree | | Option | What it is | Option A | AOAC 2009.01: the enzymatic-gravimetric method used for many resistant dextrins; the figure is method-specific. | Option B | AOAC 2011.25: a different enzymatic-LC method that can include or exclude different fractions. ## Taste and sweetness The published sweetness for Resistant Dextrin is 10% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, almost neutral with a very mild sweetness; useful where the fibre should not change the flavour. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process AOAC 2009.01: the enzymatic-gravimetric method used for many resistant dextrins; the figure is method-specific. AOAC 2011.25: a different enzymatic-LC method that can include or exclude different fractions. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; low viscosity, clean solution. Stable in dry form and through normal beverage processing. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Resistant dextrin powder, Resistant dextrin syrup 70%, Resistant dextrin fine powder, Organic resistant dextrin. The primary specification is ≥85.0% (AOAC 2009.01). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; low viscosity, clean solution. 2–10% in beverages and supplements, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Do not compare an 85% figure from one method with a 90% figure from another as if they were the same measurement. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Resistant Dextrin specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Resistant Dextrin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Resistant Dextrin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Isomaltooligosaccharide (IMO) 90%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/isomaltooligosaccharide/coa/ Reviewed: 2026-11-20 Isomaltooligosaccharide (IMO) 90% (CAS —) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineIsomaltooligosaccharide (IMO) 90% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI and AOAC 2009.01. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Isomaltooligosaccharide (IMO) 90% | | Parameter | Specification | IMO (dry basis) | ≥90.0% (HPLC-RI) | Dietary fibre | ≥85.0% (AOAC 2009.01) | Appearance | White to light yellow powder or syrup | Moisture | ≤5.0% (powder) | pH (10% solution) | 4.0–6.5 | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Ash | ≤0.5% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Isomaltooligosaccharide (IMO) 90% the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Isomaltooligosaccharide (IMO) 90% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Isomaltooligosaccharide (IMO) 90% is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI and AOAC 2009.01 reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Isomaltooligosaccharide (IMO) 90% the moisture limit is ≤5.0% (powder). The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Isomaltooligosaccharide (IMO) 90% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Isomaltooligosaccharide (IMO) 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltooligosaccharide (IMO) 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltooligosaccharide (IMO) 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Isomaltooligosaccharide (IMO) 90% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/isomaltooligosaccharide/grades/ Reviewed: 2026-11-20 Isomaltooligosaccharide (IMO) 90% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Isomaltooligosaccharide (IMO) 90% is no exception: IMO 90% powder and IMO 90% syrup can share an assay and still behave differently in the line. ## The grade map Isomaltooligosaccharide (IMO) 90% grades | | Grade | Best fit | What changes | IMO 90% powder | Beverages and supplements | Standard powder | IMO 90% syrup | Beverage and syrup lines | Water and solids must be specified | IMO 50% syrup | Cost-sensitive food use | Lower active load ## Sweetness and taste The indicative sweetness is 40–60% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild, clean sweetness with a slight body; less sweet than sucrose. The use level is 3–10% in beverages and foods, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; low viscosity at use levels. Hygroscopic; store sealed below 25 °C. ## The grade decision The level-four page for this product compares Powder with Syrup. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. IMO powder vs syrup: the water and the fibre dose A 75% IMO syrup contributes water and a different fibre dose per kilogram than the powder; the batch sheet must use the form supplied. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Isomaltooligosaccharide (IMO) 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltooligosaccharide (IMO) 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltooligosaccharide (IMO) 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Isomaltooligosaccharide (IMO) 90% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/isomaltooligosaccharide/stability/ Reviewed: 2026-11-20 Isomaltooligosaccharide (IMO) 90% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C. The specification limits moisture to ≤5.0% (powder). Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; hydrolysis should be checked at low pH and high heat. Stable across normal food pH; acidic beverages need a shelf-life check. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Isomaltooligosaccharide (IMO) 90% is added at 3–10% in beverages and foods, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; low viscosity at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Isomaltooligosaccharide (IMO) 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltooligosaccharide (IMO) 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltooligosaccharide (IMO) 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Isomaltooligosaccharide (IMO) 90%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/isomaltooligosaccharide/moq/ Reviewed: 2026-11-20 Isomaltooligosaccharide (IMO) 90% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Isomaltooligosaccharide (IMO) 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltooligosaccharide (IMO) 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltooligosaccharide (IMO) 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Isomaltooligosaccharide (IMO) 90% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/isomaltooligosaccharide/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Isomaltooligosaccharide (IMO) 90% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Isomaltooligosaccharide (IMO) 90% needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Isomaltooligosaccharide (IMO) 90% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is HPLC-RI and AOAC 2009.01. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Isomaltooligosaccharide (IMO) 90% - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Isomaltooligosaccharide (IMO) 90%, the relevant identity format is IMO ≥90%, fibre ≥85% (AOAC 2009.01). The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Isomaltooligosaccharide (IMO) 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltooligosaccharide (IMO) 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltooligosaccharide (IMO) 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 IMO powder vs syrup: the water and the fibre dose URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/isomaltooligosaccharide/grades/imo-powder-vs-syrup/ Reviewed: 2026-11-20 Two forms, two solids figures is a formulation question, not a catalogue question. A 75% IMO syrup contributes water and a different fibre dose per kilogram than the powder; the batch sheet must use the form supplied. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 75% IMO syrup contributes water and a different fibre dose per kilogram than the powder; the batch sheet must use the form supplied. ## The two options IMO powder vs syrup: the water and the fibre dose | | Option | What it is | Option A | Powder: 90% IMO, easy to weigh, hygroscopic, good for dry blends and supplements. | Option B | Syrup: easier to pump and disperse, lower solids, water activity and preservation implications. ## Taste and sweetness The published sweetness for Isomaltooligosaccharide (IMO) 90% is 40–60% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild, clean sweetness with a slight body; less sweet than sucrose. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Powder: 90% IMO, easy to weigh, hygroscopic, good for dry blends and supplements. Syrup: easier to pump and disperse, lower solids, water activity and preservation implications. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; low viscosity at use levels. Stable in dry form; hydrolysis should be checked at low pH and high heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are IMO 90% powder, IMO 90% syrup, IMO 50% syrup. The primary specification is ≥90.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; low viscosity at use levels. 3–10% in beverages and foods, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use powder for a dry blend or a capsule. Use the syrup in a liquid line where the water is already in the batch sheet, and recalculate the fibre dose on a solids basis. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Isomaltooligosaccharide (IMO) 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Isomaltooligosaccharide (IMO) 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Isomaltooligosaccharide (IMO) 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Stachyose 98%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/stachyose/coa/ Reviewed: 2026-11-20 Stachyose 98% (CAS 470-55-3) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineStachyose 98% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Stachyose 98% | | Parameter | Specification | Stachyose (dry basis) | ≥98.0% (HPLC-RI) | Appearance | White crystalline powder | Moisture | ≤5.0% | pH (10% solution) | 4.5–7.0 | Solubility | Soluble in water | Particle size | ≥95% through 80 mesh | Ash | ≤0.3% | Other sugars | ≤1.0% (HPLC-RI) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Stachyose 98% the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Stachyose 98% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Stachyose 98% is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Stachyose 98% the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Stachyose 98% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Stachyose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stachyose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stachyose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Stachyose 98% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/stachyose/grades/ Reviewed: 2026-11-20 Stachyose 98% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Stachyose 98% is no exception: Stachyose 98% and Stachyose 90% can share an assay and still behave differently in the line. ## The grade map Stachyose 98% grades | | Grade | Best fit | What changes | Stachyose 98% | Supplements and beverages | High-purity crystal | Stachyose 90% | Cost-sensitive food use | Higher other-sugar fraction | Soybean oligosaccharide blend | Mixed oligosaccharide use | Different profile and label ## Sweetness and taste The indicative sweetness is 20–30% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with a clean finish; at high dose a slight beany note can appear. The use level is 0.5–5% in beverages and supplements, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; low viscosity at use levels. Hygroscopic; store sealed. ## The grade decision The level-four page for this product compares Stachyose with Raffinose. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Stachyose vs raffinose: two soybean oligosaccharides Stachyose and raffinose are different oligosaccharides with different molecular weights, sweetness and analytical profiles. They are not interchangeable. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Stachyose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stachyose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stachyose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Stachyose 98% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/stachyose/stability/ Reviewed: 2026-11-20 Stachyose 98% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; hydrolysis should be checked at low pH and high heat. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Stachyose 98% is added at 0.5–5% in beverages and supplements, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; low viscosity at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Stachyose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stachyose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stachyose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Stachyose 98%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/stachyose/moq/ Reviewed: 2026-11-20 Stachyose 98% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Stachyose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stachyose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stachyose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Stachyose 98% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/stachyose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Stachyose 98% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Stachyose 98% needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Stachyose 98% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is HPLC-RI. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Stachyose 98% - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Stachyose 98%, the relevant identity format is Stachyose ≥98%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Stachyose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stachyose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stachyose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Stachyose vs raffinose: two soybean oligosaccharides URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/stachyose/grades/stachyose-vs-raffinose/ Reviewed: 2026-11-20 Different sugars, different profiles is a formulation question, not a catalogue question. Stachyose and raffinose are different oligosaccharides with different molecular weights, sweetness and analytical profiles. They are not interchangeable. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineStachyose and raffinose are different oligosaccharides with different molecular weights, sweetness and analytical profiles. They are not interchangeable. ## The two options Stachyose vs raffinose: two soybean oligosaccharides | | Option | What it is | Option A | Stachyose: a tetrasaccharide, ≥98% grade, mild sweetness and a clean profile. | Option B | Raffinose: a trisaccharide, ≥98% grade, a different molecular weight and a different blend behaviour. ## Taste and sweetness The published sweetness for Stachyose 98% is 20–30% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with a clean finish; at high dose a slight beany note can appear. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Stachyose: a tetrasaccharide, ≥98% grade, mild sweetness and a clean profile. Raffinose: a trisaccharide, ≥98% grade, a different molecular weight and a different blend behaviour. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; low viscosity at use levels. Stable in dry form; hydrolysis should be checked at low pH and high heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Stachyose 98%, Stachyose 90%, Soybean oligosaccharide blend. The primary specification is ≥98.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; low viscosity at use levels. 0.5–5% in beverages and supplements, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision If the application is a soybean oligosaccharide blend, specify the full profile rather than one component. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Stachyose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stachyose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stachyose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Maltooligosaccharide 90%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/maltooligosaccharide/coa/ Reviewed: 2026-11-20 Maltooligosaccharide 90% (CAS —) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineMaltooligosaccharide 90% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI and AOAC 2009.01. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Maltooligosaccharide 90% | | Parameter | Specification | Maltooligosaccharide (dry basis) | ≥90.0% (HPLC-RI) | Degree of polymerisation | DP 2–7 | Dietary fibre | ≥80.0% (AOAC 2009.01) | Appearance | White to light yellow powder or syrup | Moisture | ≤5.0% (powder) | pH (10% solution) | 4.0–6.5 | Solubility | Freely soluble in water | Ash | ≤0.5% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Maltooligosaccharide 90% the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Maltooligosaccharide 90% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Maltooligosaccharide 90% is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI and AOAC 2009.01 reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Maltooligosaccharide 90% the moisture limit is ≤5.0% (powder). The particle size is stated on the specification. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Maltooligosaccharide 90% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Maltooligosaccharide 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltooligosaccharide 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltooligosaccharide 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Maltooligosaccharide 90% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/maltooligosaccharide/grades/ Reviewed: 2026-11-20 Maltooligosaccharide 90% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Maltooligosaccharide 90% is no exception: MOS 90% powder and MOS 90% syrup can share an assay and still behave differently in the line. ## The grade map Maltooligosaccharide 90% grades | | Grade | Best fit | What changes | MOS 90% powder | Beverages and supplements | Standard grade | MOS 90% syrup | Syrup lines | Water and solids must be specified | MOS 70% syrup | Cost-sensitive food use | Lower active load ## Sweetness and taste The indicative sweetness is 40–60% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild, clean sweetness with a little body; less sweet than sucrose. The use level is 3–10% in beverages and foods, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; low viscosity. Hygroscopic; store sealed. ## The grade decision The level-four page for this product compares Powder with Syrup. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Maltooligosaccharide powder vs syrup: solids and handling A 75% MOS syrup delivers 25% water and a different fibre dose per kilogram than the powder. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Maltooligosaccharide 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltooligosaccharide 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltooligosaccharide 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Maltooligosaccharide 90% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/maltooligosaccharide/stability/ Reviewed: 2026-11-20 Maltooligosaccharide 90% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed. The specification limits moisture to ≤5.0% (powder). Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; hydrolysis should be checked at low pH and high heat. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Maltooligosaccharide 90% is added at 3–10% in beverages and foods, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; low viscosity. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Maltooligosaccharide 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltooligosaccharide 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltooligosaccharide 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Maltooligosaccharide 90%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/maltooligosaccharide/moq/ Reviewed: 2026-11-20 Maltooligosaccharide 90% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Maltooligosaccharide 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltooligosaccharide 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltooligosaccharide 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Maltooligosaccharide 90% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/maltooligosaccharide/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Maltooligosaccharide 90% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Maltooligosaccharide 90% needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Maltooligosaccharide 90% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is HPLC-RI and AOAC 2009.01. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Maltooligosaccharide 90% - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Maltooligosaccharide 90%, the relevant identity format is MOS ≥90%, DP 2–7, fibre ≥80%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Maltooligosaccharide 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltooligosaccharide 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltooligosaccharide 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Maltooligosaccharide powder vs syrup: solids and handling URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/maltooligosaccharide/grades/mos-powder-vs-syrup/ Reviewed: 2026-11-20 The form changes the dose is a formulation question, not a catalogue question. A 75% MOS syrup delivers 25% water and a different fibre dose per kilogram than the powder. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 75% MOS syrup delivers 25% water and a different fibre dose per kilogram than the powder. ## The two options Maltooligosaccharide powder vs syrup: solids and handling | | Option | What it is | Option A | Powder: 90% MOS, easy to weigh, hygroscopic, good for dry blends. | Option B | Syrup: easier to pump, lower solids, water and preservation implications. ## Taste and sweetness The published sweetness for Maltooligosaccharide 90% is 40–60% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild, clean sweetness with a little body; less sweet than sucrose. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Powder: 90% MOS, easy to weigh, hygroscopic, good for dry blends. Syrup: easier to pump, lower solids, water and preservation implications. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; low viscosity. Stable in dry form; hydrolysis should be checked at low pH and high heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are MOS 90% powder, MOS 90% syrup, MOS 70% syrup. The primary specification is ≥90.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; low viscosity. 3–10% in beverages and foods, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use powder for a dry blend. Use the syrup in a liquid line where the water is in the batch sheet, and recalculate the fibre dose on a solids basis. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Maltooligosaccharide 90% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Maltooligosaccharide 90%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Maltooligosaccharide 90%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Acacia Gum (Gum Arabic): what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/acacia-gum/coa/ Reviewed: 2026-11-20 Acacia Gum (Gum Arabic) (CAS 9000-01-5) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineAcacia Gum (Gum Arabic) is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is AOAC 2009.01 and HPLC-RI sugar profile. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Acacia Gum (Gum Arabic) | | Parameter | Specification | Dietary fibre | ≥85.0% (AOAC 2009.01) | Appearance | White to cream-coloured powder | Moisture | ≤8.0% | pH (10% solution) | 4.0–6.5 | Solubility | Soluble in water; low viscosity | Particle size | ≥95% through 80 mesh | Ash | ≤4.0% | Viscosity | Specified for the grade | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Acacia Gum (Gum Arabic) the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Acacia Gum (Gum Arabic) - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Acacia Gum (Gum Arabic) is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not AOAC 2009.01 and HPLC-RI sugar profile reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Acacia Gum (Gum Arabic) the moisture limit is ≤8.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Acacia Gum (Gum Arabic) can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Acacia Gum (Gum Arabic) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acacia Gum (Gum Arabic). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acacia Gum (Gum Arabic): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Acacia Gum (Gum Arabic) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/acacia-gum/grades/ Reviewed: 2026-11-20 Acacia Gum (Gum Arabic) is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Acacia Gum (Gum Arabic) is no exception: Spray-dried acacia and Acacia granular can share an assay and still behave differently in the line. ## The grade map Acacia Gum (Gum Arabic) grades | | Grade | Best fit | What changes | Spray-dried acacia | Beverages and emulsions | Low viscosity, clean label | Acacia granular | Dry blends | Better flow | Acacia fibre 90% | Higher fibre content | Higher fibre, higher cost ## Sweetness and taste The indicative sweetness is <5% of sucrose; essentially non-sweet. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Almost neutral with a faint gum note; used for body and emulsion stability, not sweetness. The use level is 1–10% in beverages and foods, depending on the fibre and texture target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; low viscosity even at high solids. Hygroscopic; store sealed and dry. ## The grade decision The level-four page for this product compares Spray-dried acacia with Acacia fibre 90%. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Acacia gum vs a high-fibre acacia grade: the dose and the texture Acacia gum is an emulsifier and body agent; a high-fibre acacia grade is specified for the fibre content. The use level and the texture are different. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Acacia Gum (Gum Arabic) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acacia Gum (Gum Arabic). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acacia Gum (Gum Arabic): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Acacia Gum (Gum Arabic) stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/acacia-gum/stability/ Reviewed: 2026-11-20 Acacia Gum (Gum Arabic) is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed and dry. The specification limits moisture to ≤8.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; viscosity and colour should be checked after heat. Stable across a wide pH range; acidic systems should be tested for viscosity. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Acacia Gum (Gum Arabic) is added at 1–10% in beverages and foods, depending on the fibre and texture target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; low viscosity even at high solids. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Acacia Gum (Gum Arabic) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acacia Gum (Gum Arabic). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acacia Gum (Gum Arabic): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Acacia Gum (Gum Arabic): MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/acacia-gum/moq/ Reviewed: 2026-11-20 Acacia Gum (Gum Arabic) is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Acacia Gum (Gum Arabic) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acacia Gum (Gum Arabic). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acacia Gum (Gum Arabic): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Acacia Gum (Gum Arabic) is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/acacia-gum/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Acacia Gum (Gum Arabic) can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Acacia Gum (Gum Arabic) needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Acacia Gum (Gum Arabic) - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is AOAC 2009.01 and HPLC-RI sugar profile. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Acacia Gum (Gum Arabic) - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Acacia Gum (Gum Arabic), the relevant identity format is Acacia fibre ≥85%, low-viscosity polysaccharide. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Acacia Gum (Gum Arabic) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acacia Gum (Gum Arabic). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acacia Gum (Gum Arabic): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Acacia gum vs a high-fibre acacia grade: the dose and the texture URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/acacia-gum/grades/acacia-gum-vs-fibre/ Reviewed: 2026-11-20 Gum and fibre are not the same specification is a formulation question, not a catalogue question. Acacia gum is an emulsifier and body agent; a high-fibre acacia grade is specified for the fibre content. The use level and the texture are different. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineAcacia gum is an emulsifier and body agent; a high-fibre acacia grade is specified for the fibre content. The use level and the texture are different. ## The two options Acacia gum vs a high-fibre acacia grade: the dose and the texture | | Option | What it is | Option A | Spray-dried acacia: the standard catalog grade. | Option B | Acacia fibre 90%: a higher fibre load, a different use level and a viscosity that needs the method. ## Taste and sweetness The published sweetness for Acacia Gum (Gum Arabic) is <5% of sucrose; essentially non-sweet. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Almost neutral with a faint gum note; used for body and emulsion stability, not sweetness. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Spray-dried acacia: the standard catalog grade. Acacia fibre 90%: a higher fibre load, a different use level and a viscosity that needs the method. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; low viscosity even at high solids. Stable in dry form; viscosity and colour should be checked after heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Spray-dried acacia, Acacia granular, Acacia fibre 90%. The primary specification is ≥85.0% (AOAC 2009.01). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; low viscosity even at high solids. 1–10% in beverages and foods, depending on the fibre and texture target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the gum for emulsion stability and body; choose the high-fibre grade for the fibre content. Check the analytical method and the viscosity before comparing prices. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Acacia Gum (Gum Arabic) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Acacia Gum (Gum Arabic). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Acacia Gum (Gum Arabic): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Partially Hydrolyzed Guar Gum (PHGG): what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/partially-hydrolyzed-guar-gum/coa/ Reviewed: 2026-11-20 Partially Hydrolyzed Guar Gum (PHGG) (CAS 9000-30-0 (guar gum basis)) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one linePartially Hydrolyzed Guar Gum (PHGG) is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is AOAC 2009.01 and HPLC-RI sugar profile. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Partially Hydrolyzed Guar Gum (PHGG) | | Parameter | Specification | Dietary fibre | ≥85.0% (AOAC 2009.01) | Appearance | White to off-white powder | Moisture | ≤6.0% | pH (1% solution) | 4.0–7.0 | Solubility | Soluble in water; low viscosity | Particle size | ≥95% through 80 mesh | Ash | ≤1.0% | Viscosity | Low; specified for the grade | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Partially Hydrolyzed Guar Gum (PHGG) the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Partially Hydrolyzed Guar Gum (PHGG) - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Partially Hydrolyzed Guar Gum (PHGG) is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not AOAC 2009.01 and HPLC-RI sugar profile reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Partially Hydrolyzed Guar Gum (PHGG) the moisture limit is ≤6.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Partially Hydrolyzed Guar Gum (PHGG) can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Partially Hydrolyzed Guar Gum (PHGG) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Partially Hydrolyzed Guar Gum (PHGG). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Partially Hydrolyzed Guar Gum (PHGG): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Partially Hydrolyzed Guar Gum (PHGG) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/partially-hydrolyzed-guar-gum/grades/ Reviewed: 2026-11-20 Partially Hydrolyzed Guar Gum (PHGG) is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Partially Hydrolyzed Guar Gum (PHGG) is no exception: PHGG 85% powder and PHGG 90% can share an assay and still behave differently in the line. ## The grade map Partially Hydrolyzed Guar Gum (PHGG) grades | | Grade | Best fit | What changes | PHGG 85% powder | Beverages and supplements | Low viscosity | PHGG 90% | Higher fibre content | Higher fibre, higher cost | PHGG instant | Dry mixes | Dispersion grade ## Sweetness and taste The indicative sweetness is <5% of sucrose; essentially non-sweet. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, almost neutral; useful where the fibre must not change the flavour or the viscosity. The use level is 2–10% in beverages and foods, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; low viscosity compared with native guar gum. Hygroscopic; store sealed. ## The grade decision The level-four page for this product compares PHGG with Native guar gum. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. PHGG vs native guar gum: viscosity is the difference PHGG is hydrolysed to a low viscosity; native guar gum is a thickener. They are not interchangeable in a beverage. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Partially Hydrolyzed Guar Gum (PHGG) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Partially Hydrolyzed Guar Gum (PHGG). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Partially Hydrolyzed Guar Gum (PHGG): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Partially Hydrolyzed Guar Gum (PHGG) stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/partially-hydrolyzed-guar-gum/stability/ Reviewed: 2026-11-20 Partially Hydrolyzed Guar Gum (PHGG) is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed. The specification limits moisture to ≤6.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; viscosity and colour should be checked after heat. Stable across normal food pH; acidic systems should be tested. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Partially Hydrolyzed Guar Gum (PHGG) is added at 2–10% in beverages and foods, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; low viscosity compared with native guar gum. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Partially Hydrolyzed Guar Gum (PHGG) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Partially Hydrolyzed Guar Gum (PHGG). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Partially Hydrolyzed Guar Gum (PHGG): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Partially Hydrolyzed Guar Gum (PHGG): MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/partially-hydrolyzed-guar-gum/moq/ Reviewed: 2026-11-20 Partially Hydrolyzed Guar Gum (PHGG) is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Partially Hydrolyzed Guar Gum (PHGG) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Partially Hydrolyzed Guar Gum (PHGG). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Partially Hydrolyzed Guar Gum (PHGG): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Partially Hydrolyzed Guar Gum (PHGG) is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/partially-hydrolyzed-guar-gum/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Partially Hydrolyzed Guar Gum (PHGG) can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Partially Hydrolyzed Guar Gum (PHGG) needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Partially Hydrolyzed Guar Gum (PHGG) - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is AOAC 2009.01 and HPLC-RI sugar profile. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Partially Hydrolyzed Guar Gum (PHGG) - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Partially Hydrolyzed Guar Gum (PHGG), the relevant identity format is PHGG fibre ≥85%, low viscosity. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Partially Hydrolyzed Guar Gum (PHGG) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Partially Hydrolyzed Guar Gum (PHGG). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Partially Hydrolyzed Guar Gum (PHGG): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 PHGG vs native guar gum: viscosity is the difference URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/partially-hydrolyzed-guar-gum/grades/phgg-vs-guar-gum/ Reviewed: 2026-11-20 Same source, different polymer length is a formulation question, not a catalogue question. PHGG is hydrolysed to a low viscosity; native guar gum is a thickener. They are not interchangeable in a beverage. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one linePHGG is hydrolysed to a low viscosity; native guar gum is a thickener. They are not interchangeable in a beverage. ## The two options PHGG vs native guar gum: viscosity is the difference | | Option | What it is | Option A | PHGG: low viscosity, soluble fibre, easy to add at 2–10% without thickening. | Option B | Native guar gum: high viscosity at low use, a thickener rather than a fibre ingredient. ## Taste and sweetness The published sweetness for Partially Hydrolyzed Guar Gum (PHGG) is <5% of sucrose; essentially non-sweet. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, almost neutral; useful where the fibre must not change the flavour or the viscosity. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process PHGG: low viscosity, soluble fibre, easy to add at 2–10% without thickening. Native guar gum: high viscosity at low use, a thickener rather than a fibre ingredient. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; low viscosity compared with native guar gum. Stable in dry form; viscosity and colour should be checked after heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are PHGG 85% powder, PHGG 90%, PHGG instant. The primary specification is ≥85.0% (AOAC 2009.01). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; low viscosity compared with native guar gum. 2–10% in beverages and foods, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose PHGG when the job is fibre without viscosity. Choose native guar when the job is thickening. Check the fibre method and the source declaration in both cases. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Partially Hydrolyzed Guar Gum (PHGG) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Partially Hydrolyzed Guar Gum (PHGG). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Partially Hydrolyzed Guar Gum (PHGG): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Oat Beta-Glucan 70%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/oat-beta-glucan/coa/ Reviewed: 2026-11-20 Oat Beta-Glucan 70% (CAS —) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineOat Beta-Glucan 70% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is AOAC 995.16 and AOAC 2009.01. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Oat Beta-Glucan 70% | | Parameter | Specification | Beta-glucan | ≥70.0% (AOAC 995.16) | Dietary fibre | ≥75.0% (AOAC 2009.01) | Appearance | Off-white to light brown powder | Moisture | ≤6.0% | pH (1% suspension) | 5.0–7.5 | Solubility | Dispersible in water; viscosity depends on the grade | Particle size | ≥95% through 80 mesh | Protein | ≤8.0% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Oat Beta-Glucan 70% the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Oat Beta-Glucan 70% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Oat Beta-Glucan 70% is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not AOAC 995.16 and AOAC 2009.01 reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Oat Beta-Glucan 70% the moisture limit is ≤6.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Oat Beta-Glucan 70% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Oat Beta-Glucan 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Oat Beta-Glucan 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Oat Beta-Glucan 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Oat Beta-Glucan 70% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/oat-beta-glucan/grades/ Reviewed: 2026-11-20 Oat Beta-Glucan 70% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Oat Beta-Glucan 70% is no exception: Oat beta-glucan 70% and Oat beta-glucan 80% can share an assay and still behave differently in the line. ## The grade map Oat Beta-Glucan 70% grades | | Grade | Best fit | What changes | Oat beta-glucan 70% | Beverages and supplements | Standard concentrate | Oat beta-glucan 80% | Higher fibre content | Higher beta-glucan, higher cost | Oat beta-glucan 35% | Bakery and cereal | Lower concentrate, more oat solids ## Sweetness and taste The indicative sweetness is Not sweet at use levels. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild cereal note; used for fibre and body, not sweetness. The use level is 0.5–5% in beverages and foods, depending on the fibre and viscosity target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Dispersible in water; builds viscosity and can form a gel at higher concentrations. Hygroscopic; store sealed below 25 °C. ## The grade decision The level-four page for this product compares 70% concentrate with 80% concentrate. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Oat beta-glucan 70% vs 80%: the fibre dose and the cereal note A higher beta-glucan concentrate delivers more fibre per kilogram, but it can also change the viscosity, the colour and the cereal note. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Oat Beta-Glucan 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Oat Beta-Glucan 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Oat Beta-Glucan 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Oat Beta-Glucan 70% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/oat-beta-glucan/stability/ Reviewed: 2026-11-20 Oat Beta-Glucan 70% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed below 25 °C. The specification limits moisture to ≤6.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; viscosity and colour should be checked after heat. Stable across normal food pH; viscosity can change at extreme pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Oat Beta-Glucan 70% is added at 0.5–5% in beverages and foods, depending on the fibre and viscosity target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Dispersible in water; builds viscosity and can form a gel at higher concentrations. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Oat Beta-Glucan 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Oat Beta-Glucan 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Oat Beta-Glucan 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Oat Beta-Glucan 70%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/oat-beta-glucan/moq/ Reviewed: 2026-11-20 Oat Beta-Glucan 70% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Oat Beta-Glucan 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Oat Beta-Glucan 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Oat Beta-Glucan 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Oat Beta-Glucan 70% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/oat-beta-glucan/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Oat Beta-Glucan 70% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Oat Beta-Glucan 70% needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Oat Beta-Glucan 70% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is AOAC 995.16 and AOAC 2009.01. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Oat Beta-Glucan 70% - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Oat Beta-Glucan 70%, the relevant identity format is Beta-glucan ≥70% (AOAC 995.16). The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Oat Beta-Glucan 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Oat Beta-Glucan 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Oat Beta-Glucan 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Oat beta-glucan 70% vs 80%: the fibre dose and the cereal note URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/oat-beta-glucan/grades/oat-beta-glucan-70-vs-80/ Reviewed: 2026-11-20 Concentration is not the only difference is a formulation question, not a catalogue question. A higher beta-glucan concentrate delivers more fibre per kilogram, but it can also change the viscosity, the colour and the cereal note. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA higher beta-glucan concentrate delivers more fibre per kilogram, but it can also change the viscosity, the colour and the cereal note. ## The two options Oat beta-glucan 70% vs 80%: the fibre dose and the cereal note | | Option | What it is | Option A | 70% concentrate: a balanced fibre dose, more oat solids, a moderate cereal note. | Option B | 80% concentrate: a higher fibre load per kilogram, higher viscosity and a higher cost. ## Taste and sweetness The published sweetness for Oat Beta-Glucan 70% is Not sweet at use levels. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild cereal note; used for fibre and body, not sweetness. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process 70% concentrate: a balanced fibre dose, more oat solids, a moderate cereal note. 80% concentrate: a higher fibre load per kilogram, higher viscosity and a higher cost. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Dispersible in water; builds viscosity and can form a gel at higher concentrations. Stable in dry form; viscosity and colour should be checked after heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Oat beta-glucan 70%, Oat beta-glucan 80%, Oat beta-glucan 35%. The primary specification is ≥70.0% (AOAC 995.16). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Dispersible in water; builds viscosity and can form a gel at higher concentrations. 0.5–5% in beverages and foods, depending on the fibre and viscosity target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the fibre target and the viscosity the product can tolerate. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Oat Beta-Glucan 70% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Oat Beta-Glucan 70%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Oat Beta-Glucan 70%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Pectin (HM/LM): what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/pectin/coa/ Reviewed: 2026-11-20 Pectin (HM/LM) (CAS 9000-69-5) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one linePectin (HM/LM) is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is AOAC 2009.01 and galacturonic acid titration. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Pectin (HM/LM) | | Parameter | Specification | Galacturonic acid | ≥65.0% (dry basis) | Degree of esterification | HM 55–75%; LM 20–45% | Dietary fibre | ≥65.0% (AOAC 2009.01) | Appearance | White to light brown powder | Moisture | ≤8.0% | pH (1% solution) | 3.0–5.0 | Solubility | Soluble in water; gelation depends on the DE and the calcium | Particle size | ≥95% through 80 mesh | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Pectin (HM/LM) the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Pectin (HM/LM) - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Pectin (HM/LM) is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not AOAC 2009.01 and galacturonic acid titration reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Pectin (HM/LM) the moisture limit is ≤8.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Pectin (HM/LM) can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Pectin (HM/LM) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Pectin (HM/LM). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Pectin (HM/LM): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Pectin (HM/LM) grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/pectin/grades/ Reviewed: 2026-11-20 Pectin (HM/LM) is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Pectin (HM/LM) is no exception: High-methoxyl pectin and Low-methoxyl pectin can share an assay and still behave differently in the line. ## The grade map Pectin (HM/LM) grades | | Grade | Best fit | What changes | High-methoxyl pectin | Jams and high-sugar gels | Gels with acid and sugar | Low-methoxyl pectin | Low-sugar gels | Gels with calcium | Amidated LM pectin | Flexible gel systems | Different texture and label ## Sweetness and taste The indicative sweetness is Not sweet at use levels. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild, slightly tart; used for gel, body and fibre, not sweetness. The use level is 0.2–3% in jams, beverages and confectionery, depending on the gel system. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; HM pectin gels with acid and sugar, LM pectin with calcium. Hygroscopic; store sealed and dry. ## The grade decision The level-four page for this product compares HM pectin with LM pectin. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. HM vs LM pectin: the gel mechanism decides the recipe High-methoxyl pectin gels with acid and sugar; low-methoxyl pectin gels with calcium. They are not interchangeable in a reduced-sugar jam. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Pectin (HM/LM) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Pectin (HM/LM). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Pectin (HM/LM): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Pectin (HM/LM) stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/pectin/stability/ Reviewed: 2026-11-20 Pectin (HM/LM) is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed and dry. The specification limits moisture to ≤8.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; gel strength and colour should be checked after heat. Gelation is pH-dependent; test at the final pH and calcium level. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Pectin (HM/LM) is added at 0.2–3% in jams, beverages and confectionery, depending on the gel system. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; HM pectin gels with acid and sugar, LM pectin with calcium. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Pectin (HM/LM) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Pectin (HM/LM). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Pectin (HM/LM): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Pectin (HM/LM): MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/pectin/moq/ Reviewed: 2026-11-20 Pectin (HM/LM) is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Pectin (HM/LM) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Pectin (HM/LM). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Pectin (HM/LM): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Pectin (HM/LM) is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/pectin/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Pectin (HM/LM) can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Pectin (HM/LM) needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Pectin (HM/LM) - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is AOAC 2009.01 and galacturonic acid titration. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Pectin (HM/LM) - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Pectin (HM/LM), the relevant identity format is Galacturonic acid ≥65%, DE as specified. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Pectin (HM/LM) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Pectin (HM/LM). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Pectin (HM/LM): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 HM vs LM pectin: the gel mechanism decides the recipe URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/pectin/grades/hm-pectin-vs-lm-pectin/ Reviewed: 2026-11-20 Degree of esterification is the specification is a formulation question, not a catalogue question. High-methoxyl pectin gels with acid and sugar; low-methoxyl pectin gels with calcium. They are not interchangeable in a reduced-sugar jam. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineHigh-methoxyl pectin gels with acid and sugar; low-methoxyl pectin gels with calcium. They are not interchangeable in a reduced-sugar jam. ## The two options HM vs LM pectin: the gel mechanism decides the recipe | | Option | What it is | Option A | HM pectin: DE 55–75%, gels with acid and a high sugar solids level. | Option B | LM pectin: DE 20–45%, gels with calcium and works at lower sugar solids. ## Taste and sweetness The published sweetness for Pectin (HM/LM) is Not sweet at use levels. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild, slightly tart; used for gel, body and fibre, not sweetness. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process HM pectin: DE 55–75%, gels with acid and a high sugar solids level. LM pectin: DE 20–45%, gels with calcium and works at lower sugar solids. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; HM pectin gels with acid and sugar, LM pectin with calcium. Stable in dry form; gel strength and colour should be checked after heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are High-methoxyl pectin, Low-methoxyl pectin, Amidated LM pectin. The primary specification is ≥65.0% (dry basis). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; HM pectin gels with acid and sugar, LM pectin with calcium. 0.2–3% in jams, beverages and confectionery, depending on the gel system is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the pectin from the sugar solids and the gel system, not from the price. Test the gel at the final pH, calcium level and process temperature. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Pectin (HM/LM) specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Pectin (HM/LM). It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Pectin (HM/LM): specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Lactulose 70% Syrup: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/lactulose/coa/ Reviewed: 2026-11-20 Lactulose 70% Syrup (CAS 4618-18-2) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineLactulose 70% Syrup is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Lactulose 70% Syrup | | Parameter | Specification | Lactulose (dry basis) | ≥70.0% (HPLC-RI) | Solids | 70.0–75.0% (refractometer) | Appearance | Colourless to light yellow syrup | pH (10% solution) | 3.0–5.0 | Ash | ≤0.1% | Solubility | Miscible with water | Viscosity | Specified at 25 °C | Other sugars | ≤5.0% (HPLC-RI) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Lactulose 70% Syrup the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Lactulose 70% Syrup - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Lactulose 70% Syrup is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Lactulose 70% Syrup the moisture limit is stated on the specification. The particle size is stated on the specification. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Lactulose 70% Syrup can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Lactulose 70% Syrup specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactulose 70% Syrup. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactulose 70% Syrup: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Lactulose 70% Syrup grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/lactulose/grades/ Reviewed: 2026-11-20 Lactulose 70% Syrup is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Lactulose 70% Syrup is no exception: Lactulose 70% syrup and Lactulose powder can share an assay and still behave differently in the line. ## The grade map Lactulose 70% Syrup grades | | Grade | Best fit | What changes | Lactulose 70% syrup | Food and supplement systems | Standard syrup | Lactulose powder | Dry blends | Carrier and moisture must be specified | Custom lactulose | Ratio-specific systems | Solids and sugar profile must be specified ## Sweetness and taste The indicative sweetness is 30–50% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with body; at higher doses a slight caramel note. The use level is 1–10% in food and specialty carbohydrate systems, depending on the application. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Miscible with water; supplied as a syrup. The syrup contains water; store sealed and cool. ## The grade decision The level-four page for this product compares Syrup with Powder. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Lactulose syrup vs powder: water and solids A 70% lactulose syrup is mostly water and lactulose; a powder carries a carrier. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Lactulose 70% Syrup specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactulose 70% Syrup. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactulose 70% Syrup: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Lactulose 70% Syrup stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/lactulose/stability/ Reviewed: 2026-11-20 Lactulose 70% Syrup is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability The syrup contains water; store sealed and cool. The specification limits moisture to the stated limit. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in normal processing; colour should be checked after high heat. Stable at mildly acidic pH; very low pH and heat increase hydrolysis. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Lactulose 70% Syrup is added at 1–10% in food and specialty carbohydrate systems, depending on the application. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Miscible with water; supplied as a syrup. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Lactulose 70% Syrup specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactulose 70% Syrup. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactulose 70% Syrup: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Lactulose 70% Syrup: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/lactulose/moq/ Reviewed: 2026-11-20 Lactulose 70% Syrup is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Lactulose 70% Syrup specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactulose 70% Syrup. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactulose 70% Syrup: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Lactulose 70% Syrup is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/lactulose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Lactulose 70% Syrup can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Lactulose 70% Syrup needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Lactulose 70% Syrup - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is HPLC-RI. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Lactulose 70% Syrup - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Lactulose 70% Syrup, the relevant identity format is Lactulose ≥70%, solids 70–75%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Lactulose 70% Syrup specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactulose 70% Syrup. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactulose 70% Syrup: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Lactulose syrup vs powder: water and solids URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/lactulose/grades/lactulose-syrup-vs-powder/ Reviewed: 2026-11-20 The form changes the formula is a formulation question, not a catalogue question. A 70% lactulose syrup is mostly water and lactulose; a powder carries a carrier. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineA 70% lactulose syrup is mostly water and lactulose; a powder carries a carrier. ## The two options Lactulose syrup vs powder: water and solids | | Option | What it is | Option A | Syrup: easy to pump, water already in the process, preservation and storage implications. | Option B | Powder: higher solids per kilogram, easier for a dry blend, but a carrier and a moisture limit. ## Taste and sweetness The published sweetness for Lactulose 70% Syrup is 30–50% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with body; at higher doses a slight caramel note. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Syrup: easy to pump, water already in the process, preservation and storage implications. Powder: higher solids per kilogram, easier for a dry blend, but a carrier and a moisture limit. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Miscible with water; supplied as a syrup. Stable in normal processing; colour should be checked after high heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Lactulose 70% syrup, Lactulose powder, Custom lactulose. The primary specification is ≥70.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Miscible with water; supplied as a syrup. 1–10% in food and specialty carbohydrate systems, depending on the application is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Use the syrup in a liquid system where the water is part of the recipe. Use the powder only when the carrier and the moisture are specified. Check the food-use position before either. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Lactulose 70% Syrup specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Lactulose 70% Syrup. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Lactulose 70% Syrup: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Soybean Oligosaccharides 60%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/soybean-oligosaccharides/coa/ Reviewed: 2026-11-20 Soybean Oligosaccharides 60% (CAS —) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineSoybean Oligosaccharides 60% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Soybean Oligosaccharides 60% | | Parameter | Specification | Total oligosaccharides | ≥60.0% (HPLC-RI) | Stachyose | ≥20.0% (HPLC-RI) | Raffinose | ≥10.0% (HPLC-RI) | Appearance | White to light yellow powder or syrup | Moisture | ≤5.0% (powder) | pH (10% solution) | 4.5–7.0 | Solubility | Soluble in water | Ash | ≤0.5% | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Soybean Oligosaccharides 60% the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Soybean Oligosaccharides 60% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Soybean Oligosaccharides 60% is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Soybean Oligosaccharides 60% the moisture limit is ≤5.0% (powder). The particle size is stated on the specification. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Soybean Oligosaccharides 60% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Soybean Oligosaccharides 60% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Soybean Oligosaccharides 60%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Soybean Oligosaccharides 60%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Soybean Oligosaccharides 60% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/soybean-oligosaccharides/grades/ Reviewed: 2026-11-20 Soybean Oligosaccharides 60% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Soybean Oligosaccharides 60% is no exception: Soybean oligosaccharides 60% and Soybean oligosaccharides 70% can share an assay and still behave differently in the line. ## The grade map Soybean Oligosaccharides 60% grades | | Grade | Best fit | What changes | Soybean oligosaccharides 60% | Beverages and supplements | Standard powder | Soybean oligosaccharides 70% | Higher fibre load | Higher active, higher cost | Soybean oligosaccharides syrup | Syrup lines | Water and solids must be specified ## Sweetness and taste The indicative sweetness is 20–30% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with a slight beany note; the soy source matters. The use level is 1–5% in beverages and supplements, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; low viscosity. Hygroscopic; store sealed. ## The grade decision The level-four page for this product compares Soybean oligosaccharides with FOS. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Soybean oligosaccharides vs FOS: different sources, different profiles Soybean oligosaccharides are built around stachyose and raffinose; FOS is a fructose polymer. The labels, the taste and the analytical methods differ. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Soybean Oligosaccharides 60% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Soybean Oligosaccharides 60%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Soybean Oligosaccharides 60%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Soybean Oligosaccharides 60% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/soybean-oligosaccharides/stability/ Reviewed: 2026-11-20 Soybean Oligosaccharides 60% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed. The specification limits moisture to ≤5.0% (powder). Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; hydrolysis should be checked at low pH and heat. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Soybean Oligosaccharides 60% is added at 1–5% in beverages and supplements, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; low viscosity. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Soybean Oligosaccharides 60% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Soybean Oligosaccharides 60%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Soybean Oligosaccharides 60%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Soybean Oligosaccharides 60%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/soybean-oligosaccharides/moq/ Reviewed: 2026-11-20 Soybean Oligosaccharides 60% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Soybean Oligosaccharides 60% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Soybean Oligosaccharides 60%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Soybean Oligosaccharides 60%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Soybean Oligosaccharides 60% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/soybean-oligosaccharides/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Soybean Oligosaccharides 60% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Soybean Oligosaccharides 60% needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Soybean Oligosaccharides 60% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is HPLC-RI. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Soybean Oligosaccharides 60% - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Soybean Oligosaccharides 60%, the relevant identity format is Total oligosaccharides ≥60%, stachyose + raffinose profile. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Soybean Oligosaccharides 60% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Soybean Oligosaccharides 60%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Soybean Oligosaccharides 60%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Soybean oligosaccharides vs FOS: different sources, different profiles URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/soybean-oligosaccharides/grades/soybean-oligosaccharides-vs-fos/ Reviewed: 2026-11-20 A soy-derived oligosaccharide is not FOS is a formulation question, not a catalogue question. Soybean oligosaccharides are built around stachyose and raffinose; FOS is a fructose polymer. The labels, the taste and the analytical methods differ. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineSoybean oligosaccharides are built around stachyose and raffinose; FOS is a fructose polymer. The labels, the taste and the analytical methods differ. ## The two options Soybean oligosaccharides vs FOS: different sources, different profiles | | Option | What it is | Option A | Soybean oligosaccharides: a soy-derived mixture, a mild sweetness and a specific stachyose/raffinose profile. | Option B | FOS: a fructose oligosaccharide, a different source, a different sweetness and a different fibre method. ## Taste and sweetness The published sweetness for Soybean Oligosaccharides 60% is 20–30% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with a slight beany note; the soy source matters. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Soybean oligosaccharides: a soy-derived mixture, a mild sweetness and a specific stachyose/raffinose profile. FOS: a fructose oligosaccharide, a different source, a different sweetness and a different fibre method. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; low viscosity. Stable in dry form; hydrolysis should be checked at low pH and heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Soybean oligosaccharides 60%, Soybean oligosaccharides 70%, Soybean oligosaccharides syrup. The primary specification is ≥60.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; low viscosity. 1–5% in beverages and supplements, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the application and the process, then confirm the particle size, carrier and use level in a matrix trial. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Soybean Oligosaccharides 60% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Soybean Oligosaccharides 60%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Soybean Oligosaccharides 60%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Raffinose 98%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/raffinose/coa/ Reviewed: 2026-11-20 Raffinose 98% (CAS 512-69-6) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineRaffinose 98% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-RI. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Raffinose 98% | | Parameter | Specification | Raffinose (dry basis) | ≥98.0% (HPLC-RI) | Appearance | White crystalline powder | Moisture | ≤5.0% | pH (10% solution) | 4.5–7.0 | Solubility | Soluble in water | Particle size | ≥95% through 80 mesh | Ash | ≤0.3% | Other sugars | ≤1.0% (HPLC-RI) | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Raffinose 98% the identity evidence used for release is: - HPLC-RI sugar and oligosaccharide profile of Raffinose 98% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity HPLC-RI sugar and oligosaccharide profile of Raffinose 98% is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-RI reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Raffinose 98% the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Raffinose 98% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Raffinose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Raffinose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Raffinose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Raffinose 98% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/raffinose/grades/ Reviewed: 2026-11-20 Raffinose 98% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Raffinose 98% is no exception: Raffinose 98% and Raffinose 90% can share an assay and still behave differently in the line. ## The grade map Raffinose 98% grades | | Grade | Best fit | What changes | Raffinose 98% | Supplements and beverages | High-purity crystal | Raffinose 90% | Cost-sensitive food use | Higher other-sugar fraction | Raffinose granular | Dry blends | Better flow ## Sweetness and taste The indicative sweetness is 20–30% of sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Mild sweetness with a clean finish; the oligosaccharide note is subtle. The use level is 0.5–5% in beverages and supplements, depending on the fibre target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; a clean, low-viscosity solution. Hygroscopic; store sealed. ## The grade decision The level-four page for this product compares Raffinose with Stachyose. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Raffinose vs stachyose: two oligosaccharides with different labels Raffinose is a trisaccharide; stachyose is a tetrasaccharide. They can be sold as a soybean oligosaccharide blend, but they are not the same product. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Raffinose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Raffinose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Raffinose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Raffinose 98% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/raffinose/stability/ Reviewed: 2026-11-20 Raffinose 98% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Hygroscopic; store sealed. The specification limits moisture to ≤5.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; hydrolysis should be checked at low pH and heat. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Raffinose 98% is added at 0.5–5% in beverages and supplements, depending on the fibre target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; a clean, low-viscosity solution. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Raffinose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Raffinose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Raffinose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Raffinose 98%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/raffinose/moq/ Reviewed: 2026-11-20 Raffinose 98% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Raffinose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Raffinose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Raffinose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Raffinose 98% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/raffinose/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Raffinose 98% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Raffinose 98% needs both. ## Why identity is a separate test The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - HPLC-RI sugar and oligosaccharide profile of Raffinose 98% - AOAC enzymatic fibre method appropriate to the grade - Degree of polymerisation or component distribution - Moisture, ash and solution clarity For this grade, the primary assay is HPLC-RI. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - Maltodextrin, glucose or sucrose used as a bulking agent - A lower-fibre grade sold as Raffinose 98% - A different fibre or hydrocolloid presented as the named grade - A fibre method that is not stated on the certificate None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Raffinose 98%, the relevant identity format is Raffinose ≥98%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Raffinose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Raffinose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Raffinose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Raffinose vs stachyose: two oligosaccharides with different labels URL: https://sweeteners.rainwoodbio.com/products/soluble-fibres/raffinose/grades/raffinose-vs-stachyose/ Reviewed: 2026-11-20 Different molecules, different profiles is a formulation question, not a catalogue question. Raffinose is a trisaccharide; stachyose is a tetrasaccharide. They can be sold as a soybean oligosaccharide blend, but they are not the same product. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineRaffinose is a trisaccharide; stachyose is a tetrasaccharide. They can be sold as a soybean oligosaccharide blend, but they are not the same product. ## The two options Raffinose vs stachyose: two oligosaccharides with different labels | | Option | What it is | Option A | Raffinose: a trisaccharide, ≥98% grade, a mild sweetness and a clean profile. | Option B | Stachyose: a tetrasaccharide, ≥98% grade, a different molecular weight and blend behaviour. ## Taste and sweetness The published sweetness for Raffinose 98% is 20–30% of sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Mild sweetness with a clean finish; the oligosaccharide note is subtle. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process Raffinose: a trisaccharide, ≥98% grade, a mild sweetness and a clean profile. Stachyose: a tetrasaccharide, ≥98% grade, a different molecular weight and blend behaviour. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; a clean, low-viscosity solution. Stable in dry form; hydrolysis should be checked at low pH and heat. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Raffinose 98%, Raffinose 90%, Raffinose granular. The primary specification is ≥98.0% (HPLC-RI). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; a clean, low-viscosity solution. 0.5–5% in beverages and supplements, depending on the fibre target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision If the brief is a soybean oligosaccharide blend, specify the full profile and the source rather than a single component. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Raffinose 98% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Raffinose 98%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Raffinose 98%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Stevia-Erythritol Blend 1%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/stevia-erythritol-blend/coa/ Reviewed: 2026-11-20 Stevia-Erythritol Blend 1% (CAS —) is a sweetener blend. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineStevia-Erythritol Blend 1% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-UV for steviol glycosides and HPLC-RI for erythritol. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Stevia-Erythritol Blend 1% | | Parameter | Specification | Steviol glycosides | 0.9–1.1% (HPLC-UV) | Rebaudioside A | 0.5–0.8% (HPLC-UV) | Erythritol | ≥98.0% (HPLC-RI) | Appearance | White to off-white powder | Moisture | ≤0.5% | Solubility | Soluble in water | Particle size | ≥95% through 60 mesh | Homogeneity | Specified by the blend protocol | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Stevia-Erythritol Blend 1% the identity evidence used for release is: - Assay of each active in Stevia-Erythritol Blend 1% - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend Assay of each active in Stevia-Erythritol Blend 1% is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-UV for steviol glycosides and HPLC-RI for erythritol reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Stevia-Erythritol Blend 1% the moisture limit is ≤0.5%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Stevia-Erythritol Blend 1% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Stevia-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stevia-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stevia-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Stevia-Erythritol Blend 1% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/stevia-erythritol-blend/grades/ Reviewed: 2026-11-20 Stevia-Erythritol Blend 1% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Stevia-Erythritol Blend 1% is no exception: Stevia-erythritol 1% and Stevia-erythritol 2% can share an assay and still behave differently in the line. ## The grade map Stevia-Erythritol Blend 1% grades | | Grade | Best fit | What changes | Stevia-erythritol 1% | Tabletop and beverages | Standard ratio | Stevia-erythritol 2% | Higher sweetness | Lower use rate | Custom ratio | Ratio-specific systems | Active content and homogeneity must be specified ## Sweetness and taste The indicative sweetness is 3–5 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Sweet with the cooling effect of erythritol and a light stevia note; cleaner at lower doses. The use level is 1–10% in tabletop and beverages, depending on the sweetness and body target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; the erythritol dissolves endothermically. Low to moderate; store sealed. ## The grade decision The level-four page for this product compares 1% blend with 2% blend. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Stevia-erythritol 1% vs 2%: the ratio and the cooling The two options are different specifications, not two names for the same drum. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Stevia-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stevia-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stevia-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Stevia-Erythritol Blend 1% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/stevia-erythritol-blend/stability/ Reviewed: 2026-11-20 Stevia-Erythritol Blend 1% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low to moderate; store sealed. The specification limits moisture to ≤0.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; taste should be checked after the heat step. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Stevia-Erythritol Blend 1% is added at 1–10% in tabletop and beverages, depending on the sweetness and body target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; the erythritol dissolves endothermically. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Stevia-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stevia-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stevia-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Stevia-Erythritol Blend 1%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/stevia-erythritol-blend/moq/ Reviewed: 2026-11-20 Stevia-Erythritol Blend 1% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Stevia-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stevia-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stevia-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Stevia-Erythritol Blend 1% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/stevia-erythritol-blend/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Stevia-Erythritol Blend 1% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Stevia-Erythritol Blend 1% needs both. ## Why identity is a separate test The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - Assay of each active in Stevia-Erythritol Blend 1% - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend For this grade, the primary assay is HPLC-UV for steviol glycosides and HPLC-RI for erythritol. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - The declared ratio does not match the measured actives - A cheaper carrier or bulking agent used without declaration - Segregation of the high-intensity component during transport - One active omitted or substituted without a label change None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Stevia-Erythritol Blend 1%, the relevant identity format is Steviol glycosides 0.9–1.1%, erythritol ≥98%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Stevia-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stevia-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stevia-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Stevia-erythritol 1% vs 2%: the ratio and the cooling URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/stevia-erythritol-blend/grades/stevia-erythritol-ratio/ Reviewed: 2026-11-20 The active load changes the use level is a formulation question, not a catalogue question. The two options are different specifications, not two names for the same drum. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe two options are different specifications, not two names for the same drum. ## The two options Stevia-erythritol 1% vs 2%: the ratio and the cooling | | Option | What it is | Option A | 1% blend: a higher use rate, more erythritol bulk and cooling, a lower stevia note. | Option B | 2% blend: a lower use rate, less bulk and cooling, a stronger stevia note. ## Taste and sweetness The published sweetness for Stevia-Erythritol Blend 1% is 3–5 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Sweet with the cooling effect of erythritol and a light stevia note; cleaner at lower doses. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process 1% blend: a higher use rate, more erythritol bulk and cooling, a lower stevia note. 2% blend: a lower use rate, less bulk and cooling, a stronger stevia note. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; the erythritol dissolves endothermically. Stable in dry form; taste should be checked after the heat step. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Stevia-erythritol 1%, Stevia-erythritol 2%, Custom ratio. The primary specification is 0.9–1.1% (HPLC-UV). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; the erythritol dissolves endothermically. 1–10% in tabletop and beverages, depending on the sweetness and body target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Start with the target sweetness and the body. If the product needs bulk and cooling, the 1% blend is easier. If the product needs a small dose and a higher sweetness, the 2% blend is the starting point. Confirm the ratio by a matrix trial. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Stevia-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Stevia-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Stevia-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Monk Fruit-Erythritol Blend 1%: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-erythritol-blend/coa/ Reviewed: 2026-11-20 Monk Fruit-Erythritol Blend 1% (CAS —) is a sweetener blend. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineMonk Fruit-Erythritol Blend 1% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC for mogrosides and HPLC-RI for erythritol. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Monk Fruit-Erythritol Blend 1% | | Parameter | Specification | Mogroside V | 0.9–1.1% (HPLC) | Total mogrosides | ≥1.2% (HPLC) | Erythritol | ≥98.0% (HPLC-RI) | Appearance | White to off-white powder | Moisture | ≤0.5% | Solubility | Soluble in water | Particle size | ≥95% through 60 mesh | Homogeneity | Specified by the blend protocol | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Monk Fruit-Erythritol Blend 1% the identity evidence used for release is: - Assay of each active in Monk Fruit-Erythritol Blend 1% - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend Assay of each active in Monk Fruit-Erythritol Blend 1% is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC for mogrosides and HPLC-RI for erythritol reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Monk Fruit-Erythritol Blend 1% the moisture limit is ≤0.5%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Monk Fruit-Erythritol Blend 1% can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Monk Fruit-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Monk Fruit-Erythritol Blend 1% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-erythritol-blend/grades/ Reviewed: 2026-11-20 Monk Fruit-Erythritol Blend 1% is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Monk Fruit-Erythritol Blend 1% is no exception: Monk fruit-erythritol 1% and Monk fruit-erythritol 2% can share an assay and still behave differently in the line. ## The grade map Monk Fruit-Erythritol Blend 1% grades | | Grade | Best fit | What changes | Monk fruit-erythritol 1% | Tabletop and beverages | Standard ratio | Monk fruit-erythritol 2% | Higher sweetness | Lower use rate | Custom ratio | Ratio-specific systems | Active content and homogeneity must be specified ## Sweetness and taste The indicative sweetness is 2–4 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, fruit-forward sweetness with erythritol cooling; less liquorice than stevia. The use level is 1–10% in tabletop and beverages, depending on the sweetness and body target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Soluble in water; the erythritol dissolves endothermically. Low to moderate; store sealed. ## The grade decision The level-four page for this product compares 1% blend with 2% blend. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Which Monk Fruit-Erythritol Blend 1% grade fits the brief? The two options are different specifications, not two names for the same drum. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Monk Fruit-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Monk Fruit-Erythritol Blend 1% stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-erythritol-blend/stability/ Reviewed: 2026-11-20 Monk Fruit-Erythritol Blend 1% is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low to moderate; store sealed. The specification limits moisture to ≤0.5%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Stable in dry form; taste should be checked after the heat step. Stable across normal food pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Monk Fruit-Erythritol Blend 1% is added at 1–10% in tabletop and beverages, depending on the sweetness and body target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Soluble in water; the erythritol dissolves endothermically. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Monk Fruit-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Monk Fruit-Erythritol Blend 1%: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-erythritol-blend/moq/ Reviewed: 2026-11-20 Monk Fruit-Erythritol Blend 1% is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Monk Fruit-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Monk Fruit-Erythritol Blend 1% is what the specification says URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-erythritol-blend/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Monk Fruit-Erythritol Blend 1% can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Monk Fruit-Erythritol Blend 1% needs both. ## Why identity is a separate test The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - Assay of each active in Monk Fruit-Erythritol Blend 1% - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend For this grade, the primary assay is HPLC for mogrosides and HPLC-RI for erythritol. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - The declared ratio does not match the measured actives - A cheaper carrier or bulking agent used without declaration - Segregation of the high-intensity component during transport - One active omitted or substituted without a label change None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Monk Fruit-Erythritol Blend 1%, the relevant identity format is Mogroside V 0.9–1.1%, erythritol ≥98%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Monk Fruit-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Which Monk Fruit-Erythritol Blend 1% grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-erythritol-blend/grades/monk-fruit-erythritol-ratio/ Reviewed: 2026-11-20 The ratio changes the formula and the file is a formulation question, not a catalogue question. The two options are different specifications, not two names for the same drum. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe two options are different specifications, not two names for the same drum. ## The two options Which Monk Fruit-Erythritol Blend 1% grade fits the brief? | | Option | What it is | Option A | 1% blend: more erythritol bulk and cooling, a lower monk fruit note and a higher use rate. | Option B | 2% blend: less bulk and cooling, a stronger monk fruit note and a lower use rate. ## Taste and sweetness The published sweetness for Monk Fruit-Erythritol Blend 1% is 2–4 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, fruit-forward sweetness with erythritol cooling; less liquorice than stevia. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process 1% blend: more erythritol bulk and cooling, a lower monk fruit note and a higher use rate. 2% blend: less bulk and cooling, a stronger monk fruit note and a lower use rate. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Soluble in water; the erythritol dissolves endothermically. Stable in dry form; taste should be checked after the heat step. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Monk fruit-erythritol 1%, Monk fruit-erythritol 2%, Custom ratio. The primary specification is 0.9–1.1% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Soluble in water; the erythritol dissolves endothermically. 1–10% in tabletop and beverages, depending on the sweetness and body target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Then test the cooling and the fruit note in the real matrix. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Monk Fruit-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Sucralose-Ace-K Blend 25/75: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/sucralose-acesulfame-blend/coa/ Reviewed: 2026-11-20 Sucralose-Ace-K Blend 25/75 (CAS —) is a sweetener blend. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineSucralose-Ace-K Blend 25/75 is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC for both actives. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Sucralose-Ace-K Blend 25/75 | | Parameter | Specification | Sucralose | 24.5–25.5% (HPLC) | Acesulfame potassium | 74.5–75.5% (HPLC) | Appearance | White powder | Moisture | ≤1.0% | Solubility | Freely soluble in water | Particle size | ≥95% through 80 mesh | Homogeneity | Specified by the blend protocol | Bulk density | 0.50–0.80 g/mL | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Sucralose-Ace-K Blend 25/75 the identity evidence used for release is: - Assay of each active in Sucralose-Ace-K Blend 25/75 - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend Assay of each active in Sucralose-Ace-K Blend 25/75 is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC for both actives reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Sucralose-Ace-K Blend 25/75 the moisture limit is ≤1.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Sucralose-Ace-K Blend 25/75 can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Sucralose-Ace-K Blend 25/75 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose-Ace-K Blend 25/75. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose-Ace-K Blend 25/75: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Sucralose-Ace-K Blend 25/75 grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/sucralose-acesulfame-blend/grades/ Reviewed: 2026-11-20 Sucralose-Ace-K Blend 25/75 is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Sucralose-Ace-K Blend 25/75 is no exception: 25/75 sucralose-Ace-K and 50/50 sucralose-Ace-K can share an assay and still behave differently in the line. ## The grade map Sucralose-Ace-K Blend 25/75 grades | | Grade | Best fit | What changes | 25/75 sucralose-Ace-K | Beverages and tabletop | Standard ratio | 50/50 sucralose-Ace-K | Different sweetness curve | Higher sucralose, higher cost | Custom ratio | Ratio-specific systems | Each active and homogeneity must be specified ## Sweetness and taste The indicative sweetness is 250–300 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Fast onset from the Ace-K with a rounder tail from the sucralose; the blend reduces the metallic linger of Ace-K alone. The use level is 0.005–0.03% in beverages, depending on the target sucrose equivalence. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; clear at use levels. Low to moderate; store sealed. ## The grade decision The level-four page for this product compares 25/75 with 50/50. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Sucralose-Ace-K 25/75 vs 50/50: the ratio is the curve The ratio changes the onset, the linger and the cost. A 25/75 blend is not a stronger or weaker version of a 50/50 blend; it is a different sweetness curve. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Sucralose-Ace-K Blend 25/75 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose-Ace-K Blend 25/75. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose-Ace-K Blend 25/75: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Sucralose-Ace-K Blend 25/75 stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/sucralose-acesulfame-blend/stability/ Reviewed: 2026-11-20 Sucralose-Ace-K Blend 25/75 is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low to moderate; store sealed. The specification limits moisture to ≤1.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Both actives are stable through normal pasteurisation; validate the blend after the heat step. Stable across normal beverage pH. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Sucralose-Ace-K Blend 25/75 is added at 0.005–0.03% in beverages, depending on the target sucrose equivalence. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; clear at use levels. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Sucralose-Ace-K Blend 25/75 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose-Ace-K Blend 25/75. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose-Ace-K Blend 25/75: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Sucralose-Ace-K Blend 25/75: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/sucralose-acesulfame-blend/moq/ Reviewed: 2026-11-20 Sucralose-Ace-K Blend 25/75 is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Sucralose-Ace-K Blend 25/75 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose-Ace-K Blend 25/75. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose-Ace-K Blend 25/75: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Sucralose-Ace-K Blend 25/75 is what the specification says URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/sucralose-acesulfame-blend/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Sucralose-Ace-K Blend 25/75 can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Sucralose-Ace-K Blend 25/75 needs both. ## Why identity is a separate test The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - Assay of each active in Sucralose-Ace-K Blend 25/75 - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend For this grade, the primary assay is HPLC for both actives. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - The declared ratio does not match the measured actives - A cheaper carrier or bulking agent used without declaration - Segregation of the high-intensity component during transport - One active omitted or substituted without a label change None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Sucralose-Ace-K Blend 25/75, the relevant identity format is Sucralose 24.5–25.5%, Ace-K 74.5–75.5%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Sucralose-Ace-K Blend 25/75 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose-Ace-K Blend 25/75. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose-Ace-K Blend 25/75: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Sucralose-Ace-K 25/75 vs 50/50: the ratio is the curve URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/sucralose-acesulfame-blend/grades/sucralose-ace-k-ratio/ Reviewed: 2026-11-20 One blend, two taste directions is a formulation question, not a catalogue question. The ratio changes the onset, the linger and the cost. A 25/75 blend is not a stronger or weaker version of a 50/50 blend; it is a different sweetness curve. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe ratio changes the onset, the linger and the cost. A 25/75 blend is not a stronger or weaker version of a 50/50 blend; it is a different sweetness curve. ## The two options Sucralose-Ace-K 25/75 vs 50/50: the ratio is the curve | | Option | What it is | Option A | 25/75: more Ace-K, a faster onset and a lower cost, with more metallic linger at high dose. | Option B | 50/50: more sucralose, a rounder and cleaner tail, a higher cost per kilogram. ## Taste and sweetness The published sweetness for Sucralose-Ace-K Blend 25/75 is 250–300 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Fast onset from the Ace-K with a rounder tail from the sucralose; the blend reduces the metallic linger of Ace-K alone. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process 25/75: more Ace-K, a faster onset and a lower cost, with more metallic linger at high dose. 50/50: more sucralose, a rounder and cleaner tail, a higher cost per kilogram. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; clear at use levels. Both actives are stable through normal pasteurisation; validate the blend after the heat step. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are 25/75 sucralose-Ace-K, 50/50 sucralose-Ace-K, Custom ratio. The primary specification is 24.5–25.5% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; clear at use levels. 0.005–0.03% in beverages, depending on the target sucrose equivalence is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Taste both at equal sucrose equivalence in the final matrix. If the tail is the problem, increase the sucralose fraction; if the cost is the problem and the tail is acceptable, keep more Ace-K. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Sucralose-Ace-K Blend 25/75 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Sucralose-Ace-K Blend 25/75. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Sucralose-Ace-K Blend 25/75: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Allulose-Stevia Blend 5/95: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/allulose-stevia-blend/coa/ Reviewed: 2026-11-20 Allulose-Stevia Blend 5/95 (CAS —) is a sweetener blend. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineAllulose-Stevia Blend 5/95 is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-UV for steviol glycosides and HPLC-RI for allulose. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Allulose-Stevia Blend 5/95 | | Parameter | Specification | Steviol glycosides | 4.5–5.5% (HPLC-UV) | Rebaudioside A | ≥4.0% (HPLC-UV) | Allulose | ≥94.0% (HPLC-RI) | Appearance | White to off-white powder | Moisture | ≤1.0% | Solubility | Freely soluble in water | Particle size | ≥95% through 60 mesh | Homogeneity | Specified by the blend protocol | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Allulose-Stevia Blend 5/95 the identity evidence used for release is: - Assay of each active in Allulose-Stevia Blend 5/95 - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend Assay of each active in Allulose-Stevia Blend 5/95 is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC-UV for steviol glycosides and HPLC-RI for allulose reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Allulose-Stevia Blend 5/95 the moisture limit is ≤1.0%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Allulose-Stevia Blend 5/95 can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Allulose-Stevia Blend 5/95 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose-Stevia Blend 5/95. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose-Stevia Blend 5/95: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Allulose-Stevia Blend 5/95 grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/allulose-stevia-blend/grades/ Reviewed: 2026-11-20 Allulose-Stevia Blend 5/95 is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Allulose-Stevia Blend 5/95 is no exception: Allulose-stevia 5/95 and Allulose-stevia 2/98 can share an assay and still behave differently in the line. ## The grade map Allulose-Stevia Blend 5/95 grades | | Grade | Best fit | What changes | Allulose-stevia 5/95 | Beverages and bakery | Standard ratio | Allulose-stevia 2/98 | More body, lower sweetness | Higher use rate | Custom ratio | Ratio-specific systems | Both components and homogeneity must be specified ## Sweetness and taste The indicative sweetness is 15–20 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Sweet with allulose body and a stevia top note; the blend can brown like a sugar. The use level is 0.5–5% in beverages and bakery, depending on the sweetness and body target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; allulose adds body and browning. Low to moderate; store sealed. ## The grade decision The level-four page for this product compares 5/95 with 2/98. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Which Allulose-Stevia Blend 5/95 grade fits the brief? The two options are different specifications, not two names for the same drum. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Allulose-Stevia Blend 5/95 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose-Stevia Blend 5/95. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose-Stevia Blend 5/95: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Allulose-Stevia Blend 5/95 stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/allulose-stevia-blend/stability/ Reviewed: 2026-11-20 Allulose-Stevia Blend 5/95 is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low to moderate; store sealed. The specification limits moisture to ≤1.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Allulose browns; taste and colour should be checked after the heat step. Stable across normal food pH; colour should be checked at high heat. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Allulose-Stevia Blend 5/95 is added at 0.5–5% in beverages and bakery, depending on the sweetness and body target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; allulose adds body and browning. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Allulose-Stevia Blend 5/95 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose-Stevia Blend 5/95. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose-Stevia Blend 5/95: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Allulose-Stevia Blend 5/95: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/allulose-stevia-blend/moq/ Reviewed: 2026-11-20 Allulose-Stevia Blend 5/95 is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Allulose-Stevia Blend 5/95 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose-Stevia Blend 5/95. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose-Stevia Blend 5/95: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Allulose-Stevia Blend 5/95 is what the specification says URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/allulose-stevia-blend/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Allulose-Stevia Blend 5/95 can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Allulose-Stevia Blend 5/95 needs both. ## Why identity is a separate test The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - Assay of each active in Allulose-Stevia Blend 5/95 - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend For this grade, the primary assay is HPLC-UV for steviol glycosides and HPLC-RI for allulose. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - The declared ratio does not match the measured actives - A cheaper carrier or bulking agent used without declaration - Segregation of the high-intensity component during transport - One active omitted or substituted without a label change None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Allulose-Stevia Blend 5/95, the relevant identity format is Steviol glycosides 4.5–5.5%, allulose ≥94%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Allulose-Stevia Blend 5/95 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose-Stevia Blend 5/95. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose-Stevia Blend 5/95: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Which Allulose-Stevia Blend 5/95 grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/allulose-stevia-blend/grades/allulose-stevia-ratio/ Reviewed: 2026-11-20 Two grades, one application decision is a formulation question, not a catalogue question. The two options are different specifications, not two names for the same drum. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe two options are different specifications, not two names for the same drum. ## The two options Which Allulose-Stevia Blend 5/95 grade fits the brief? | | Option | What it is | Option A | 5/95: higher sweetness, lower use rate, less allulose body and browning. | Option B | 2/98: lower sweetness, higher use rate, more allulose body and browning. ## Taste and sweetness The published sweetness for Allulose-Stevia Blend 5/95 is 15–20 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Sweet with allulose body and a stevia top note; the blend can brown like a sugar. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process 5/95: higher sweetness, lower use rate, less allulose body and browning. 2/98: lower sweetness, higher use rate, more allulose body and browning. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; allulose adds body and browning. Allulose browns; taste and colour should be checked after the heat step. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Allulose-stevia 5/95, Allulose-stevia 2/98, Custom ratio. The primary specification is 4.5–5.5% (HPLC-UV). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; allulose adds body and browning. 0.5–5% in beverages and bakery, depending on the sweetness and body target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Choose the ratio from the body and browning target, not from the sweetness alone. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Allulose-Stevia Blend 5/95 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Allulose-Stevia Blend 5/95. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Allulose-Stevia Blend 5/95: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 01 Monk Fruit-Allulose Blend 2/98: what the certificate of analysis reports URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-allulose-blend/coa/ Reviewed: 2026-11-20 Monk Fruit-Allulose Blend 2/98 (CAS —) is a sweetener blend. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer. In one lineMonk Fruit-Allulose Blend 2/98 is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own. ## The release panel The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC for mogrosides and HPLC-RI for allulose. The appearance, moisture, particle size and contaminant block are released against the same lot. Batch COA · Monk Fruit-Allulose Blend 2/98 | | Parameter | Specification | Mogroside V | 1.8–2.2% (HPLC) | Total mogrosides | ≥2.4% (HPLC) | Allulose | ≥97.0% (HPLC-RI) | Appearance | White to off-white powder | Moisture | ≤1.0% | Solubility | Freely soluble in water | Particle size | ≥95% through 60 mesh | Homogeneity | Specified by the blend protocol | Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg | Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass. ## Identity is a separate line Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Monk Fruit-Allulose Blend 2/98 the identity evidence used for release is: - Assay of each active in Monk Fruit-Allulose Blend 2/98 - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend Assay of each active in Monk Fruit-Allulose Blend 2/98 is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses. ## What the assay proves — and what it does not HPLC for mogrosides and HPLC-RI for allulose reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so. ## Batch-specific means the lot number matches The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence. Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it. ## Contaminants, moisture and the physical tests The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills. For Monk Fruit-Allulose Blend 2/98 the moisture limit is ≤1.0%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS. ## What to read first - The identity line, not only the assay. Check the method and the reference standard. - The assay basis: as-is, dried or anhydrous. The same lot reads differently against each. - The related-substance or other-isomer profile, because it is often the taste signal. - The moisture and particle size, because they drive the process and the shelf life. - The lot number and the manufacturing date, before the result. ## Comparing two suppliers Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Monk Fruit-Allulose Blend 2/98 can be compared only when the lines behind the percentage are the same. Read the related pages for this grade: Monk Fruit-Allulose Blend 2/98 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Allulose Blend 2/98. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Allulose Blend 2/98: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02 Which Monk Fruit-Allulose Blend 2/98 grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-allulose-blend/grades/ Reviewed: 2026-11-20 Monk Fruit-Allulose Blend 2/98 is published as a family of grades, not a single drum. The grade decides the particle size, the carrier, the taste, the dissolution behaviour and sometimes the carrier system. The table below is the published starting point; the specification for the chosen grade is the document that governs release. In one lineThe grade is decided by the dosage form and the process. Monk Fruit-Allulose Blend 2/98 is no exception: Monk fruit-allulose 2/98 and Monk fruit-allulose 1/99 can share an assay and still behave differently in the line. ## The grade map Monk Fruit-Allulose Blend 2/98 grades | | Grade | Best fit | What changes | Monk fruit-allulose 2/98 | Beverages and bakery | Standard ratio | Monk fruit-allulose 1/99 | More body, lower sweetness | Higher use rate | Custom ratio | Ratio-specific systems | Both components and homogeneity must be specified ## Sweetness and taste The indicative sweetness is 8–12 × sucrose, indicative. That figure is a starting point, not a promise: sweetness depends on the matrix, the pH, the temperature, the other sweeteners and the person tasting. Clean, fruit-forward sweetness with allulose body; less stevia linger. The use level is 1–8% in beverages and bakery, depending on the sweetness and body target. Use that range as a bench-trial window. The final level is set by the matrix, the process and the taste target. ## What changes between grades Particle size changes dissolution speed, dust and flow. A carrier changes the active content, the flow and the taste. A liquid grade adds water and a preservation requirement. A granulated grade can reduce dust and improve flow, but it may dissolve more slowly. None of these is a cosmetic difference, and none of them is captured by the assay alone. The functional properties behind those differences are stated on the technical data sheet: Freely soluble in water; allulose adds body and browning. Low to moderate; store sealed. ## The grade decision The level-four page for this product compares 2/98 with 1/99. It sets out the choice in the terms that matter at the bench: taste, solubility, process and cost per unit of sweetness. Which Monk Fruit-Allulose Blend 2/98 grade fits the brief? The two options are different specifications, not two names for the same drum. ## How to run the trial - Fix the target sucrose equivalence, not the powder weight. Compare grades at the same delivered sweetness. - Test at the final pH, temperature and matrix. Water alone hides the acid and protein effects. - Measure the sweetness at the start, the middle and the end of the shelf-life window. - Check the physical result: clarity, colour, viscosity, crystallisation or mouthfeel as relevant. - Record the lot number and the use level, so the result can be repeated on the next lot. ## Ordering and traceability The grade on the purchase order should match the grade in the specification and on the COA. A generic name on the order and a specific grade in the file is a documentation gap waiting for a reviewer to find it. Read the related pages for this grade: Monk Fruit-Allulose Blend 2/98 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Allulose Blend 2/98. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Allulose Blend 2/98: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 03 Monk Fruit-Allulose Blend 2/98 stability: bulk, matrix and packaging URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-allulose-blend/stability/ Reviewed: 2026-11-20 Monk Fruit-Allulose Blend 2/98 is stable enough to ship and store under normal conditions when it is packed correctly. The interesting failures happen at the edges: moisture, heat, low pH, a reactive matrix or a pack that lets water in. This page separates the bulk powder from the finished formula, because they fail for different reasons. In one lineThe powder is not the fragile part. The pack, the water activity, the process temperature and the matrix decide the shelf life. ## Bulk stability Low to moderate; store sealed. The specification limits moisture to ≤1.0%. Store the sealed pack below 25 °C, away from direct sunlight, strong odours and oxidising materials. A opened pack should be resealed or used within the agreed period; a liner left open in a humid room is the most common cause of caking. The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The bulk powder is tested against the release specification at the time of manufacture. That result is a starting point, not a shelf-life promise. If the project needs a defined shelf life, ask for stability data on the grade and the pack, or run a study on the retained sample. ## Stability in the finished matrix Allulose browns; taste and colour should be checked after the heat step. Stable across normal food pH; colour should be checked at high heat. Taste can move before the assay does. A sweetener can pass its assay after six months and still taste different because a minor component has hydrolysed, a carrier has picked up water, or the matrix has changed. For that reason a stability protocol should include a sensory check, not only a chemical result. ## What the process does Monk Fruit-Allulose Blend 2/98 is added at 1–8% in beverages and bakery, depending on the sweetness and body target. Add it at the point in the process where the temperature and the water activity are lowest, unless the formula requires it earlier for dispersion. In a beverage, make a pre-mix or a stock solution to avoid dust and local over-concentration. In a dry blend, pre-blend with a small portion of the bulk carrier before scaling. Freely soluble in water; allulose adds body and browning. In a clear beverage, check the solution after the heat step and after 24 hours; a haze that appears later is often a solubility or a protein interaction problem rather than a loss of sweetness. ## Packaging and shelf life 1 kg foil pouch and 25 kg fiber drum are the standard packs. The food-grade liner is part of the packaging specification, not an accessory. A drum that has been opened and resealed in a humid room can pick up enough water to change the flow and the weight of the scoop, even if the assay is unchanged. Set the shelf life from the stability data for the grade and the pack. A common default is 24 months for a sealed, dry powder stored below 25 °C, but the figure should be confirmed for the specific product and pack rather than assumed from a catalogue. ## A practical stability protocol - Store three lots at 25 °C/60% RH and at 40 °C/75% RH for the planned shelf life. - Test assay, moisture, appearance, particle size and microbiology at 0, 3, 6, 12 and 24 months. - Add a sensory check at each point, using the same matrix and the same panel. - Test the finished product as well as the bulk powder, because the matrix can be harsher than the pack. - Keep the retained sample sealed and record the lot, the pack and the storage condition. Read the related pages for this grade: Monk Fruit-Allulose Blend 2/98 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Allulose Blend 2/98. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Allulose Blend 2/98: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 04 Monk Fruit-Allulose Blend 2/98: MOQ, packaging and ordering URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-allulose-blend/moq/ Reviewed: 2026-11-20 Monk Fruit-Allulose Blend 2/98 is quoted against a written specification, a quantity, a destination and a document list. The catalogue entry gives the entry quantity and the standard pack; the quotation gives the rest. This page explains what is fixed, what is flexible and what the order needs before it can be confirmed. In one lineOne kilogram is the entry quantity, packed from a released lot with that lot's COA. The quotation follows the specification, not a catalogue number. ## Entry quantity The minimum is 1 kg, drawn from a released lot. The sample is normally 100–500 g and carries the same lot's COA, so the material tested at the bench is the material that ships. Bulk quantities are packed in 1 kg foil pouch or 25 kg fiber drum, with a food-grade liner. If the project needs a grade that is not published, the minimum is set by the smallest batch that can be manufactured and released against the specification. That is a development question, not a catalogue question, and it is answered before a sample is promised. ## What the quotation needs - The exact grade and specification, including the assay basis and the particle size. - The quantity and the pack size. - The dosage form and the process step where the ingredient is added. - The destination market and the document requirements. - Any allergen, GMO, organic or customer-specific declaration. - The requested Incoterm and the delivery address. With those six points, the quotation can state the grade, the pack, the lead time, the documents and the commercial terms together. Without them, the reply is a range, not a quotation. ## Sampling and approval The sample is packed from a released lot and sent with its COA. Test it in the real matrix, at the real use level, with the real process. A sample that passes in water and fails in an acidic beverage has told you something useful; a sample that passes only in water has not tested the application. Keep the retained portion sealed and labelled with the lot number. If the first production lot is compared with the sample, the comparison is only valid when both are the same grade and the same lot family. ## Lead time and dispatch The indicative lead time is 3–10 days after specification and order confirmation. The figure starts when the specification is agreed, not when the first email is sent. A custom mesh, a custom carrier or a new document can add time before the lot is released. Dispatch is arranged against the agreed Incoterm. The document pack is completed before the drum leaves the warehouse: batch COA, TDS, SDS, allergen and GMO statements, origin record and the specification comparison. Additional third-party testing is arranged before dispatch, not after the container is booked. ## On receipt Check the drum, the lot label and the COA against the purchase order. Record the quantity, the pack condition and the storage location. If the material is sampled on receipt, keep the sample sealed and label it with the lot, the date and the sampler. A COA that does not match the lot on the drum is a reason to hold the material before it enters production. Read the related pages for this grade: Monk Fruit-Allulose Blend 2/98 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Allulose Blend 2/98. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Allulose Blend 2/98: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 05 How to prove Monk Fruit-Allulose Blend 2/98 is what the specification says URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-allulose-blend/identity/ Reviewed: 2026-11-20 Identity is the first question a buyer should ask and the last one a certificate usually answers. Monk Fruit-Allulose Blend 2/98 can meet its assay and still be the wrong isomer, the wrong salt, a blend, or a material from a different source. This page sets out the tests that answer the identity question and the substitutions that make it worth asking. In one lineAn assay tells you how much of the named material is present. Identity tells you that the material is the one named. Monk Fruit-Allulose Blend 2/98 needs both. ## Why identity is a separate test The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The assay method is chosen to measure the active. It is not necessarily chosen to distinguish the active from a close relative. That is why an identity specification names the reference standard, the chromatographic system and the secondary confirmation, not only a percentage. ## The tests that answer it - Assay of each active in Monk Fruit-Allulose Blend 2/98 - Homogeneity across the lot - Carrier identity and particle-size match - Moisture and flow of the finished blend For this grade, the primary assay is HPLC for mogrosides and HPLC-RI for allulose. The identity evidence starts with the retention time and the reference standard, then adds the secondary test that makes the result specific. A single retention time from a single injection is weak identity evidence. ## Common substitutions and what they look like - The declared ratio does not match the measured actives - A cheaper carrier or bulking agent used without declaration - Segregation of the high-intensity component during transport - One active omitted or substituted without a label change None of these substitutions is always visible from the assay. A blend can be built to hit the same percentage. A lower-grade extract can be blended up with a carrier. The useful warning signs are a price that is far below the market, a certificate that reports only one figure, a specification that omits the other-isomer or related-substance profile, and a supplier who cannot name the reference standard. ## Reading the chromatogram Ask for the chromatogram, not only the table. The main peak should be the named material, the integration should be reproducible, and the minor peaks should match the specification. A chromatogram that shows a broad, unresolved hump where the main peak should be is a quality signal even if the integration reports 98%. For Monk Fruit-Allulose Blend 2/98, the relevant identity format is Mogroside V 1.8–2.2%, allulose ≥97%. The certificate should report those values on the same lot, with the method and the reference standard named. ## A practical authenticity protocol - Match the lot number across the COA, the drum and the retained sample. - Run the primary identity test against a certified reference standard. - Run the secondary test that distinguishes the material from its closest substitute. - Check the other-isomer, related-substance or sugar profile for the substitution the assay cannot see. - Compare the result with the previous lot and with the retained sample. - If the result is ambiguous, send a sample to an independent laboratory with the reference standard and the specification. ## When to use a third party Use an outside laboratory when the material is from a new source, when the price is materially below the market, when the source is unknown, or when the first shipment is critical to the project. The useful brief is narrow: test the identity questions the supplier's certificate leaves open, not a full repeat of the same panel. Read the related pages for this grade: Monk Fruit-Allulose Blend 2/98 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Allulose Blend 2/98. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Allulose Blend 2/98: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ### 02.1 Which Monk Fruit-Allulose Blend 2/98 grade fits the brief? URL: https://sweeteners.rainwoodbio.com/products/sweetener-blends/monk-fruit-allulose-blend/grades/monk-fruit-allulose-ratio/ Reviewed: 2026-11-20 Two grades, one application decision is a formulation question, not a catalogue question. The two options are different specifications, not two names for the same drum. This page compares the two options in the terms that decide a bench trial: identity, taste, solubility, process and the cost per unit of sweetness. In one lineThe two options are different specifications, not two names for the same drum. ## The two options Which Monk Fruit-Allulose Blend 2/98 grade fits the brief? | | Option | What it is | Option A | 2/98: higher monk fruit sweetness, lower use rate, less allulose body. | Option B | 1/99: lower sweetness, higher use rate, more allulose body and browning. ## Taste and sweetness The published sweetness for Monk Fruit-Allulose Blend 2/98 is 8–12 × sucrose, indicative. That figure is an average, and the difference between the two options is usually in the shape of the curve rather than the peak intensity. Clean, fruit-forward sweetness with allulose body; less stevia linger. Run the comparison at equal sucrose equivalence. If one option is dosed by weight and the other by active content, convert both to the same delivered sweetness before the panel tastes them. A difference in the use level is not a difference in taste unless the delivery is matched. ## Solubility and process 2/98: higher monk fruit sweetness, lower use rate, less allulose body. 1/99: lower sweetness, higher use rate, more allulose body and browning. The practical questions are whether the material dissolves or disperses at the target use level, whether it survives the heat step, and whether it changes the viscosity or the clarity of the finished product. For this product, Freely soluble in water; allulose adds body and browning. Allulose browns; taste and colour should be checked after the heat step. A bench trial that ignores the process step can pick the wrong option with a clean conscience. ## Grade and use level The published grades are Monk fruit-allulose 2/98, Monk fruit-allulose 1/99, Custom ratio. The primary specification is 1.8–2.2% (HPLC). The use level is application-specific: start from the target sucrose equivalence, then adjust for the matrix, the process and the other sweeteners in the formula. For this grade, Freely soluble in water; allulose adds body and browning. 1–8% in beverages and bakery, depending on the sweetness and body target is the current starting window; confirm it in a bench trial rather than scaling directly from the catalogue. ## The decision Then choose the ratio by taste and texture. The recommendation is a starting point, not a rule. The final choice belongs to the formula, the process and the market, and it should be recorded with the trial result and the lot numbers so it can be repeated. ## A three-day trial plan - Day one: prepare stock solutions or pre-blends of both options at equal sucrose equivalence. - Day two: taste in the real matrix at the real pH, with the real process, and record the onset, peak, tail and any off-note. - Day three: repeat the tasting after the heat step or 24 hours of hold, and compare the physical result: clarity, colour, viscosity or crystallisation. Keep the two stock solutions labelled with the lot and the use level. A trial without the lot number is an anecdote, and an anecdote is expensive to scale. Read the related pages for this grade: Monk Fruit-Allulose Blend 2/98 specification and grades, COA and batch testing and identity and adulteration. ## How this document is controlled This page is part of the technical file for Monk Fruit-Allulose Blend 2/98. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch. The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there. The product hub for this grade is Monk Fruit-Allulose Blend 2/98: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library. ## Editorial boundary No prices, no placeholder data, no borrowed certificates and no invented customer names or volumes. Every published figure is tied to a specification and a method. Contact: info@rainwoodbio.com.