Resistant Dextrin: what the certificate of analysis reports
Resistant Dextrin (CAS —) is a soluble fibre. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer.
Resistant Dextrin is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own.
The release panel
The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is AOAC 2009.01 dietary fibre and HPLC-RI sugar profile. The appearance, moisture, particle size and contaminant block are released against the same lot.
| Parameter | Specification |
|---|---|
| Dietary fibre | ≥85.0% (AOAC 2009.01) |
| Resistant dextrin | ≥85.0% (HPLC-RI) |
| Appearance | White to light yellow powder |
| Moisture | ≤5.0% |
| pH (10% solution) | 3.0–6.0 |
| Solubility | Freely soluble in water; low viscosity |
| Particle size | ≥95% through 80 mesh |
| Bulk density | 0.40–0.70 g/mL |
| Glucose | ≤5.0% (HPLC-RI) |
| Heavy metals | Pb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg |
| Microbiology | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent |
Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass.
Identity is a separate line
Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Resistant Dextrin the identity evidence used for release is:
- Dietary fibre by AOAC 2009.01
- HPLC-RI sugar and dextrin profile
- Moisture and ash
- Solution clarity
Dietary fibre by AOAC 2009.01 is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses.
What the assay proves — and what it does not
AOAC 2009.01 dietary fibre and HPLC-RI sugar profile reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests.
The active is a polymer distribution, not a single molecule, so the fibre method and the degree of polymerisation define what the percentage means. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so.
Batch-specific means the lot number matches
The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence.
Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it.
Contaminants, moisture and the physical tests
The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills.
For Resistant Dextrin the moisture limit is ≤5.0%. The particle size is ≥95% through 80 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS.
What to read first
- The identity line, not only the assay. Check the method and the reference standard.
- The assay basis: as-is, dried or anhydrous. The same lot reads differently against each.
- The related-substance or other-isomer profile, because it is often the taste signal.
- The moisture and particle size, because they drive the process and the shelf life.
- The lot number and the manufacturing date, before the result.
Comparing two suppliers
Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Resistant Dextrin can be compared only when the lines behind the percentage are the same.
Read the related pages for this grade: Resistant Dextrin specification and grades, COA and batch testing and identity and adulteration.
How this document is controlled
This page is part of the technical file for Resistant Dextrin. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch.
The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there.
The product hub for this grade is Resistant Dextrin: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library.
Related documents
Quick inquiry
Ask about this grade
Name, company, email and the question. The product and the page you are reading travel with it, so there is nothing else to select.