01 COA & batch testing

Stevia-Erythritol Blend 1%: what the certificate of analysis reports

Technical document 01 · Reviewed 2026-11-20 · Stevia-Erythritol Blend 1%

On this page
  1. The release panel
  2. Identity is a separate line
  3. What the assay proves — and what it does not
  4. Batch-specific means the lot number matches
  5. Contaminants, moisture and the physical tests
  6. What to read first
  7. Comparing two suppliers
  8. How this document is controlled

Stevia-Erythritol Blend 1% (CAS —) is a sweetener blend. The product specification is built around the exact identity, the assay method, the physical form and the batch documents, not around a catalogue description. This page explains what the certificate reports, what each figure proves and which questions the certificate cannot answer.

In one line

Stevia-Erythritol Blend 1% is released against a written specification. The certificate has to show the result, the method and the release limit for every line, not a pass mark on its own.

The release panel

The certificate follows the specification in the table below. Each result is reported for the lot, not for a generic grade, and each result is paired with the method used to obtain it. The primary assay is HPLC-UV for steviol glycosides and HPLC-RI for erythritol. The appearance, moisture, particle size and contaminant block are released against the same lot.

Batch COA · Stevia-Erythritol Blend 1%
ParameterSpecification
Steviol glycosides0.9–1.1% (HPLC-UV)
Rebaudioside A0.5–0.8% (HPLC-UV)
Erythritol≥98.0% (HPLC-RI)
AppearanceWhite to off-white powder
Moisture≤0.5%
SolubilitySoluble in water
Particle size≥95% through 60 mesh
HomogeneitySpecified by the blend protocol
Heavy metalsPb ≤0.5 · As ≤0.5 · Cd ≤0.5 · Hg ≤0.1 mg/kg
MicrobiologyAPC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent

Microbiology is reported as a separate block with the aerobic plate count, yeast and mould, E. coli and Salmonella. Heavy metals are reported individually rather than as a single total. If a result is below the limit of quantification, the certificate should say so; a blank cell is not the same as a pass.

Identity is a separate line

Purity does not prove identity. A powder can meet an assay range and still be the wrong isomer, the wrong salt or a blend of two materials. For Stevia-Erythritol Blend 1% the identity evidence used for release is:

  • Assay of each active in Stevia-Erythritol Blend 1%
  • Homogeneity across the lot
  • Carrier identity and particle-size match
  • Moisture and flow of the finished blend

Assay of each active in Stevia-Erythritol Blend 1% is the anchor. The other lines are there because a single retention time can be matched by a different molecule, and because a supplier's reference standard may not be the same standard your laboratory uses.

What the assay proves — and what it does not

HPLC-UV for steviol glycosides and HPLC-RI for erythritol reports the amount of the named material in the portion analysed. It is a quantity measurement. It does not prove that the material was made by a particular route, that the crystal form is the one ordered, or that the taste in your matrix will match the taste in water. Those are separate questions with separate tests.

The active is a ratio, not a single molecule, so each component needs its own assay and the homogeneity of the blend is part of the specification. The release limit is set on the specification, and the result is read against it. A figure at the top of the range is not automatically better than a figure in the middle unless the specification says so.

Batch-specific means the lot number matches

The certificate is only useful if the lot number on the COA, the lot number on the drum and the lot number on the retained sample are the same. A certificate copied from a previous shipment, or a certificate that reports a generic product code rather than a manufacturing lot, is not batch-specific evidence.

Ask for the manufacturing date, the retest or expiry date, the pack size and the quantity released. A COA can be accurate and still describe a lot that has been repacked. Repacking is a change to the traceability chain, and the documents should show it.

Contaminants, moisture and the physical tests

The contaminant panel is a release decision, not a formality. Lead, arsenic, cadmium and mercury are reported by ICP-MS; the limits depend on the destination market and the use. Moisture is a quality figure in its own right: it changes the usable solids, the flow and the storage behaviour. Particle size and bulk density are process figures: they decide how the powder moves, disperses and fills.

For Stevia-Erythritol Blend 1% the moisture limit is ≤0.5%. The particle size is ≥95% through 60 mesh. Both are part of the release specification and should appear on the COA, not only on the TDS.

What to read first

  • The identity line, not only the assay. Check the method and the reference standard.
  • The assay basis: as-is, dried or anhydrous. The same lot reads differently against each.
  • The related-substance or other-isomer profile, because it is often the taste signal.
  • The moisture and particle size, because they drive the process and the shelf life.
  • The lot number and the manufacturing date, before the result.

Comparing two suppliers

Put the identity, assay basis, method, impurity profile, moisture, particle size and contaminant limits side by side. If two quotations agree on the assay but use different methods or different bases, they are not quoting the same specification. Stevia-Erythritol Blend 1% can be compared only when the lines behind the percentage are the same.

Read the related pages for this grade: Stevia-Erythritol Blend 1% specification and grades, COA and batch testing and identity and adulteration.

How this document is controlled

This page is part of the technical file for Stevia-Erythritol Blend 1%. It is reviewed when the specification, the analytical method or the packing changes. The date at the top of the page is the review date; the current specification should be checked before a launch.

The commercial document is the specification agreed with the buyer, the batch COA for the lot and the technical data sheet supplied with that lot. If this page and the agreed specification disagree, the agreed specification governs the order. The page exists to explain the reasoning behind the specification, so a quality, procurement or technical reviewer can see why each line is there.

The product hub for this grade is Stevia-Erythritol Blend 1%: specification, grades and documents. The release workflow is described on the quality and documentation page, and the analytical method behind the primary assay is listed in the method library.

Quick inquiry

Ask about this grade

Name, company, email and the question. The product and the page you are reading travel with it, so there is nothing else to select.

We use your details only to answer this inquiry. Country is detected from your connection and used only for freight and compliance. Need a written quotation instead? The full form asks for quantity, preferred form, destination market and the documents you need — those answers are what turn a reply into a priced quotation instead of another round of questions.